INFLUENCE OF TYROSINE ON THE DUAL ELECTRODE ELECTROCHEMICAL DETECTION OF COPPER(II) PEPTIDE COMPLEXES

被引:34
作者
TSAI, H [1 ]
WEBER, SG [1 ]
机构
[1] UNIV PITTSBURGH,DEPT CHEM,PITTSBURGH,PA 15260
关键词
D O I
10.1021/ac00047a004
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The biuret reaction makes peptides electrochemically active. This is the basis of an electrochemical method for the detection of peptides following their liquid chromatographic separation. This paper discuses the influences tyrosine, an electroactive amino acid, on the detection of Cu(II)-peptide (biuret) complexes containing it. The dual electrode detector has an upstream anode and a downstream cathode. Tyrosine-containing peptides yield anodic signals that are approximately the sum of the tyrosine signal and the signal from the biuret complex of a nonelectroactive model peptide, phenylalanyl-glycyl-glycine (FGG). The cathodic signal is depressed in comparison to FGG. This is traced to the presence of an intramolecular reaction between Cu(III) and a reaction product resulting from the corresponding intermolecular reaction is significant (10(6)-10(7) M-1 s-1), but in practical analytical situations, the concentrations of the reactants will be small, so the reaction will not be a major factor. Sensitivities for several bioactive peptides are reported. The dependence of the signals on the position of tyrosine in a tripeptide is also studied.
引用
收藏
页码:2897 / 2903
页数:7
相关论文
共 28 条
[21]   IMPROVED DETECTION LIMITS IN THE ANALYSIS OF TYROSINE-CONTAINING POLYPEPTIDE HORMONES BY USING ELECTROCHEMICAL DETECTION [J].
SPATOLA, AF ;
BENOVITZ, DE .
JOURNAL OF CHROMATOGRAPHY, 1985, 327 (JUN) :165-171
[22]   ELECTROCHEMICAL DETECTION OF OLIGOPEPTIDES THROUGH THE PRECOLUMN FORMATION OF BIURET COMPLEXES [J].
TSAI, HY ;
WEBER, SG .
JOURNAL OF CHROMATOGRAPHY, 1991, 542 (02) :345-350
[23]   ELECTROCHEMICAL DETECTION OF DIPEPTIDES AND DIPEPTIDE AMIDES [J].
TSAI, HY ;
WEBER, SG .
JOURNAL OF CHROMATOGRAPHY, 1990, 515 :451-457
[24]   ANODIC REACTIONS OF SIMPLE PHENOLIC COMPOUNDS [J].
VERMILLION, FJ ;
PEARL, IA .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1964, 111 (12) :1392-1400
[25]   ELECTROCHEMICAL DETECTION OF PEPTIDES [J].
WARNER, AM ;
WEBER, SG .
ANALYTICAL CHEMISTRY, 1989, 61 (23) :2664-2668
[26]   BEHAVIOR OF AN ELECTROCHEMICAL DETECTOR USED IN LIQUID-CHROMATOGRAPHY AND CONTINUOUS-FLOW VOLTAMMETRY .1. MASS TRANSPORT LIMITED CURRENT [J].
WEBER, SG ;
PURDY, WC .
ANALYTICA CHIMICA ACTA, 1978, 100 (SEP) :531-544
[27]   MELANIN .1. KINETICS OF OXIDATIVE CYCLIZATION OF DOPA TO DOPACHROME [J].
YOUNG, TE ;
GRISWOLD, JR ;
HULBERT, MH .
JOURNAL OF ORGANIC CHEMISTRY, 1974, 39 (13) :1980-1982
[28]   ELECTROCHEMICAL STUDY OF THE OXIDATION OF ALPHA-METHYLDOPAMINE, ALPHA-METHYLNORADRENALINE, AND DOPAMINE [J].
YOUNG, TE ;
BABBITT, BW .
JOURNAL OF ORGANIC CHEMISTRY, 1983, 48 (04) :562-566