MEASUREMENT OF ABSOLUTE EPICARDIAL CORONARY-ARTERY FLOW AND FLOW RESERVE WITH BREATH-HOLD CINE PHASE-CONTRAST MAGNETIC-RESONANCE-IMAGING

被引:86
作者
CLARKE, GD
ECKELS, R
CHANEY, C
SMITH, D
DITTRICH, J
HUNDLEY, WG
NESSAIVER, M
LI, HF
PARKEY, RW
PESHOCK, RM
机构
[1] UNIV TEXAS, SW MED CTR, DEPT INTERNAL MED, DALLAS, TX 75235 USA
[2] PICKER INT, DIV MAGNET RESONANCE CLIN RES, HIGHLAND HTS, OH USA
关键词
BLOOD FLOW; MAGNETIC RESONANCE IMAGING; ADENOSINE;
D O I
10.1161/01.CIR.91.10.2627
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Noninvasive measurement of absolute coronary arterial flow and coronary flow reserve would be of considerable use in the diagnosis and management of patients with coronary artery disease. Phase-contrast magnetic resonance imaging (MRI) has been used to measure flow in a variety of vessels. The goal of the present study was to determine if MRI measurements of coronary artery flow in a single breath-hold can be used to determine flow reserve and the severity of pericardial stenosis. Methods and Results In eight mongrel dogs, a closed chest model of partial left anterior descending coronary artery (LAD) occlusion was created. Coronary flows in the left circumflex artery (LCx) and LAD were measured at rest and during adenosine infusion using velocity-encoded, breath-hold MRI and perivascular ultrasound (US) flowmeters. MRI measurements of absolute coronary flow and coronary flow reserve were highly correlated with US (r=.96 and .94, respectively). Flow reserve measured in the constricted LAD was significantly lower than that in the unconstricted LCx by both US (P=.002) and MRI (P=.011). Conclusions MRI measurements of coronary flow and flow reserve were in good agreement with US measurements. In addition, MRI measurements of coronary flow reserve successfully discriminated stenotic from normal vessels. These results indicate that MRI is a useful method for the noninvasive assessment of coronary flow and stenosis.
引用
收藏
页码:2627 / 2634
页数:8
相关论文
共 32 条
  • [21] MACGIBBON D, 1992, ACCURACY PERIVASCULA
  • [22] MORICH MA, 1994, Patent No. 5296810
  • [23] NESSAIVER M, 1993, CARDIOVASCULAR APPLI, P33
  • [24] ASSESSMENT OF THE FUNCTIONAL-SIGNIFICANCE OF CORONARY STENOSES - IS DIGITAL ANGIOGRAPHY THE ANSWER
    NISSEN, SE
    GURLEY, JC
    [J]. CIRCULATION, 1990, 81 (04) : 1431 - 1435
  • [25] PELC N J, 1991, Magnetic Resonance Quarterly, V7, P229
  • [26] TIME-OF-FLIGHT QUANTIFICATION OF CORONARY FLOW WITH ECHO-PLANAR MRI
    PONCELET, BP
    WEISSKOFF, RM
    WEDEEN, VJ
    BRADY, TJ
    KANTOR, H
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (04) : 447 - 457
  • [27] RICHARDS KL, 1983, MECHANICS CORONARY C, P63
  • [28] RAPID MR IMAGING OF BLOOD-FLOW WITH A PHASE-SENSITIVE, LIMITED-FLIP-ANGLE, GRADIENT RECALLED PULSE SEQUENCE - PRELIMINARY EXPERIENCE
    SPRITZER, CE
    PELC, NJ
    LEE, JN
    EVANS, AJ
    SOSTMAN, HD
    RIEDERER, SJ
    [J]. RADIOLOGY, 1990, 176 (01) : 255 - 262
  • [29] QUANTIFICATION OF COMPLEX FLOW USING MR PHASE IMAGING - A STUDY OF PARAMETERS INFLUENCING THE PHASE-VELOCITY RELATION
    STAHLBERG, F
    SONDERGAARD, L
    THOMSEN, C
    HENRIKSEN, O
    [J]. MAGNETIC RESONANCE IMAGING, 1992, 10 (01) : 13 - 23
  • [30] ACCURACY OF PHASE-CONTRAST FLOW MEASUREMENTS IN THE PRESENCE OF PARTIAL-VOLUME EFFECTS
    TANG, C
    BLATTER, DD
    PARKER, DL
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (02): : 377 - 385