PHASE DISCRIMINATION IN CONTINUOUS LIQUID-LIQUID-EXTRACTION WITH DIODE-ARRAY PHOTOMETRIC DETECTION

被引:15
作者
ORTIZBOYER, F [1 ]
GARCIAMESA, JA [1 ]
DECASTRO, MDL [1 ]
机构
[1] UNIV CORDOBA,FAC SCI,DEPT ANALYT CHEM,E-14004 CORDOBA,SPAIN
关键词
D O I
10.1021/ac00089a032
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A high-resolution phase-discrimination approach for use in continuous liquid-liquid extraction monitoring is reported that uses any available diode array spectrophotometer to monitor the segmented flow at three wavelengths: one for discriminating the phases involved, another for monitoring the target species, and the third for correction of signal fluctuations. Two sizes of organic-aqueous-phase segmentation are produced along the dynamic system: short segment lengths favoring mass transfer between the immiscible phases and longer segments formed at the expense of the shorter ones in a grouping chamber in order to allow one of the phases to fully occupy the flow cell path length line during monitoring. The proposed approach was successfully used for continuous monitoring of both aqueous and the organic phases, as well as continuous liquid-liquid extraction processes involving chemical derivatization reactions.
引用
收藏
页码:2794 / 2798
页数:5
相关论文
共 17 条
[1]   CONTINUOUS LIQUID-LIQUID-EXTRACTION FOR PRECONCENTRATION WITH ONLINE MONITORING [J].
AGUDO, M ;
RIOS, A ;
VALCARCEL, M .
ANALYTICAL CHEMISTRY, 1993, 65 (20) :2941-2943
[2]   LIQUID LIQUID EXTRACTION IN CONTINUOUS-FLOW SYSTEMS WITHOUT PHASE-SEPARATION [J].
CANETE, F ;
RIOS, A ;
DECASTRO, MDL ;
VALCARCEL, M .
ANALYTICAL CHEMISTRY, 1988, 60 (21) :2354-2357
[3]   COUPLED ROBOT-FLOW INJECTION-ANALYSIS SYSTEM FOR FULLY AUTOMATED-DETERMINATION OF TOTAL POLYPHENOLS IN OLIVE OIL [J].
GARCIAMESA, JA ;
DECASTRO, MDL ;
VALCARCEL, M .
ANALYTICAL CHEMISTRY, 1993, 65 (23) :3540-3542
[4]  
GARCIAMESA JA, 1990, ANAL CHIM ACTA, V235, P441
[5]   DETERMINATION OF OCTAN-1-OL WATER PARTITION-COEFFICIENTS BY FLOW-INJECTION EXTRACTION WITHOUT PHASE-SEPARATION [J].
KUBAN, V .
ANALYTICA CHIMICA ACTA, 1991, 248 (02) :493-499
[6]   DESIGN OF A MULTICHANNEL DROPPING SEGMENTER FOR LIQUID-LIQUID-EXTRACTION CONTINUOUS FLOW-INJECTION ANALYSIS [J].
KUBAN, V ;
INGMAN, F .
ANALYTICA CHIMICA ACTA, 1991, 245 (02) :251-257
[7]   DESIGN OF COAXIAL SEGMENTORS FOR LIQUID-LIQUID-EXTRACTION FLOW-INJECTION ANALYSIS [J].
KUBAN, V ;
DANIELSSON, LG ;
INGMAN, F .
ANALYTICAL CHEMISTRY, 1990, 62 (18) :2026-2032
[8]  
LEON LE, 1989, LAB ROBOTICS AUTOMAT, V1, P295
[9]   FLOW-INJECTION AND SOLVENT-EXTRACTION WITH INTELLIGENT SEGMENT SEPARATION - DETERMINATION OF QUATERNARY AMMONIUM-IONS BY ION-PAIRING [J].
LINDGREN, CC ;
DASGUPTA, PK .
TALANTA, 1992, 39 (02) :101-111
[10]   MECHANISM OF EXTRACTION AND BAND BROADENING IN SOLVENT-EXTRACTION FLOW-INJECTION ANALYSIS [J].
LUCY, CA ;
CANTWELL, FF .
ANALYTICAL CHEMISTRY, 1989, 61 (02) :107-114