MATERIALS CHARACTERIZATION USING ACCELERATOR MASS-SPECTROMETRY

被引:10
作者
ANTHONY, JM [1 ]
BEAVERS, RL [1 ]
BENNETT, TJ [1 ]
MATTESON, S [1 ]
MARBLE, DK [1 ]
WEATHERS, DL [1 ]
MCDANIEL, FD [1 ]
DUGGAN, JL [1 ]
机构
[1] UNIV N TEXAS,DEPT PHYS,DENTON,TX 76203
关键词
D O I
10.1016/0168-583X(91)95050-N
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Several materials, including TiH, stainless steel (No. 304), CaCO3 and a boron nitride/graphite mix have been analysed using accelerator mass spectrometry. Elemental and molecular negative ion injection have been examined to enhance the sensitivity for elements with low electron affinities. Ca and Sr negative ions, as well as metastable molecules of charge state 3 + are demonstrated. Conditions for high sensitivity analysis in unknown samples are also discussed.
引用
收藏
页码:873 / 876
页数:4
相关论文
共 11 条
[1]   ACCELERATOR MASS-SPECTROMETRY AT THE UNIVERSITY-OF-NORTH-TEXAS [J].
ANTHONY, JM ;
MATTESON, S ;
MCDANIEL, FD ;
DUGGAN, JL .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1989, 40-1 :731-733
[2]   APPLICATIONS OF ACCELERATOR MASS-SPECTROMETRY TO ELECTRONIC MATERIALS [J].
ANTHONY, JM ;
MATTESON, SE ;
MARBLE, DK ;
DUGGAN, JL ;
MCDANIEL, FC ;
DONAHUE, DJ .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1990, 50 (1-4) :262-266
[3]   ANALYSIS OF CAUSES OF PULSE-HEIGHT DEFECT AND ITS MASS DEPENDENCE FOR HEAVY-ION SILICON DETECTORS [J].
FINCH, EC .
NUCLEAR INSTRUMENTS & METHODS, 1973, 113 (01) :41-49
[4]   A HIGH-RESOLUTION ELECTROSTATIC ANALYZER FOR ACCELERATOR MASS-SPECTROMETRY [J].
MATTESON, S ;
MCDANIEL, FD ;
DUGGAN, JL ;
ANTHONY, JM ;
BENNETT, TJ ;
BEAVERS, RL .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1989, 40-1 :759-761
[5]   EVIDENCE FOR A STABLE NEGATIVE-ION OF CALCIUM [J].
PEGG, DJ ;
THOMPSON, JS ;
COMPTON, RN ;
ALTON, GD .
PHYSICAL REVIEW LETTERS, 1987, 59 (20) :2267-2270
[6]  
RAISBECK G, 1990, NUCL INSTR METH B, V52
[7]  
WEAST RC, 1984, CRC HDB CHEM PHYSICS
[8]   TRIPLY-IONIZED B2 MOLECULES FROM A TANDEM ACCELERATOR [J].
WEATHERS, DL ;
MCDANIEL, FD ;
MATTESON, S ;
DUGGAN, JL ;
ANTHONY, JM ;
DOUGLAS, MA .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1991, 56-7 :889-892
[9]   PULSE-HEIGHT DEFECTS FOR HEAVY IONS IN A SILICON SURFACE-BARRIER DETECTOR [J].
WILKINS, BD ;
FLUSS, MJ ;
KAUFMAN, SB ;
GROSS, CE ;
STEINBERG, EP .
NUCLEAR INSTRUMENTS & METHODS, 1971, 92 (03) :381-+
[10]  
Wilson R.G., 1989, SECONDARY ION MASS S