Influence of Windfarms on Power System Dynamic and Transient Stability

被引:43
作者
Anaya-Lara, Olimpo [1 ]
Hughes, F. [1 ]
Jenkins, Nicholas [1 ]
Strbac, Goran [2 ]
机构
[1] Univ Manchester, Joule Ctr Energy, Manchester M60 1QD, Lancs, England
[2] Imperial Coll London, London, England
关键词
D O I
10.1260/030952406778055018
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The interaction between bulk windfarm generation and conventional generation and its influence on network dynamic characteristics are investigated. A simple three-generator system having characteristics that may be considered representative of the major areas of the UK network is used for the dynamic studies. Time response simulation and eigenvalue analysis are used to establish basic transient and dynamic stability characteristics. The wind generation is provided either by windfarms based on Fixed Speed Induction Generators (FSIGs) or Doubly Fed Induction Generators (DFIGs). In addition, in order to provide a base-line, against which windfarm influence on network dynamics can be judged, the case where the power is provided only by conventional synchronous generation is also considered.
引用
收藏
页码:107 / 127
页数:21
相关论文
共 22 条
[1]  
Akhmatov V., 2003, Wind Engineering, V27, P79, DOI 10.1260/03095240360698537
[2]   Variable-speed wind turbines with doubly-fed induction generators. Part I: Modelling in dynamic simulation tools [J].
Akhmatov, Vladislav .
2002, Multi-Science Publishing Co. Ltd (26)
[3]   An aggregate model of a grid-connected, large-scale, offshore wind farm for power stability investigations - importance of windmill mechanical system [J].
Akhmatov, V ;
Knudsen, H .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2002, 24 (09) :709-717
[4]  
ANAYALARA O, 2004, P EWEC 2004 EUR WIND
[5]  
Bolik S. M., 2003, P 4 INT WORKSH LARG
[6]  
DTI, 2003, OUR EN FUT CREAT LOW
[7]   COMPARISON OF PRONY AND EIGENANALYSIS FOR POWER-SYSTEM CONTROL DESIGN [J].
GRUND, CE ;
PASERBA, JJ ;
HAUER, JF ;
NILSSON, S .
IEEE TRANSACTIONS ON POWER SYSTEMS, 1993, 8 (03) :964-971
[8]   Large-scale wind power integration in Norway and impact on damping in the Nordic grid [J].
Hagstrom, E ;
Norheim, I ;
Uhlen, K .
WIND ENERGY, 2005, 8 (03) :375-384
[9]   Comparison of fixed speed and doubly-fed induction wind turbines during power system disturbances [J].
Holdsworth, L ;
Wu, XG ;
Ekanayake, JB ;
Jenkins, N .
IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 2003, 150 (03) :343-352
[10]  
IEEE Committee Report, 2001, IEEE T POWER APPARAT, VPAS-100, P494