SIGNIFICANT DIFFERENCES IN FLOW STANDARDIZED BREATH SOUND SPECTRA IN PATIENTS WITH CHRONIC OBSTRUCTIVE PULMONARY-DISEASE, STABLE ASTHMA, AND HEALTHY LUNGS

被引:57
作者
MALMBERG, LP
PESU, L
SOVIJARVI, ARA
机构
[1] UNIV HELSINKI, CENT HOSP, DEPT MED, DIV PULM DIS & CLIN PHYSIOL, SF-00290 HELSINKI, FINLAND
[2] HELSINKI UNIV TECHNOL, BIOMED ENGN LAB, HELSINKI, FINLAND
关键词
RESPIRATORY SOUNDS; ASTHMA; CHRONIC OBSTRUCTIVE PULMONARY DISEASE;
D O I
10.1136/thx.50.12.1285
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background - Spectral characteristics of breath sounds in asthma and chronic obstructive pulmonary disease (COPD) have not previously been compared, although the structural differences in these disorders might be reflected in breath sounds. Methods - Flow standardised inspiratory breath sounds in patients with COPD (n = 17) and stable asthma (n = 10) with significant airways obstruction and in control patients without any respiratory disorders (n = 11) were compared in terms of estimates of the power spectrum. Breath sounds were recorded simultaneously at the chest and at the trachea. Results - The median frequency (F-50) of the mean (SD) breath sound spectra recorded at the chest was higher in asthmatics (239 (19) Hz) than in both the control patients (206 (14) Hz) and the patients with COPD (201 (21) Hz). The total spectral power of breath sounds recorded at the chest in terms of root mean square (RMS) was higher in asthmatics than in patients with COPD. In patients with COPD the spectral parameters were not statistically different from those of control patients. The F-50 recorded at the trachea in the asthmatics was significantly related to forced expiratory volume in one second (FEV(1)) (r = -0.77), but this was not seen in the other groups. Conclusions - The observed differences in frequency content of breath sounds in patients with asthma and COPD may reflect altered sound generation or transmission due to structural changes of the bronchi and the surrounding lung tissue in these diseases. Spectral analysis of breath sounds may provide a new non-invasive method for differential diagnosis of obstructive pulmonary diseases.
引用
收藏
页码:1285 / 1291
页数:7
相关论文
共 40 条
[21]   VISUAL LUNG-SOUND CHARACTERIZATION BY TIME-EXPANDED WAVE-FORM ANALYSIS [J].
MURPHY, RLH ;
HOLFORD, SK ;
KNOWLER, WC .
NEW ENGLAND JOURNAL OF MEDICINE, 1977, 296 (17) :968-971
[22]   EFFECT OF AIR-FLOW AND FLOW TRANSDUCER ON TRACHEAL BREATH SOUNDS [J].
MUSSELL, MJ ;
NAKAZONO, Y ;
MIYAMOTO, Y .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1990, 28 (06) :550-554
[23]   VESICULAR LUNG SOUND AMPLITUDE MAPPING BY AUTOMATED FLOW-GATED PHONOPNEUMOGRAPHY [J].
ODONNELL, DM ;
KRAMAN, SS .
JOURNAL OF APPLIED PHYSIOLOGY, 1982, 53 (03) :603-609
[24]   MECHANISMS OF LUNG SOUND GENERATION [J].
OLSON, DE ;
HAMMERSLEY, JR .
SEMINARS IN RESPIRATORY MEDICINE, 1985, 6 (03) :171-179
[25]  
OLSON DE, 1983, AM REV RESPIR DIS, V127, P268
[26]  
PASTERKAMP H, 1989, CHEST, V96, P1505
[27]   MEASUREMENT OF RESPIRATORY ACOUSTICAL SIGNALS - COMPARISON OF SENSORS [J].
PASTERKAMP, H ;
KRAMAN, SS ;
DEFRAIN, PD ;
WODICKA, GR .
CHEST, 1993, 104 (05) :1518-1525
[28]  
PASTERKAMP H, 1985, AM REV RESPIR DIS, V131, P61
[29]  
PLOYSONGSANG Y, 1982, AM REV RESPIR DIS, V126, P526
[30]   TRANSMISSION OF LUNG SOUNDS [J].
RICE, DA .
SEMINARS IN RESPIRATORY MEDICINE, 1985, 6 (03) :166-170