RECENT ADVANCES IN STRIPPING ANALYSIS

被引:31
作者
WANG, J
机构
[1] Department of Chemistry, New Mexico State University, Las Cruces, 88003, NM
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 1990年 / 337卷 / 05期
关键词
D O I
10.1007/BF00322854
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A review is given of the key developments of stripping voltammetry in recent years. Important advances such as non-electrolytic (adsorptive) preconcentration schemes, modified or ultramicro stripping electrodes, and versatile and rapid flow systems are discussed. Such developments substantially enhance the analytical power of stripping voltammetry, allowing it to retain its place as one of the most useful techniques for trace analysis. © 1990 Springer-Verlag.
引用
收藏
页码:508 / 511
页数:4
相关论文
共 56 条
[1]   ASSESSMENT OF DIFFERENTIAL-PULSE ADSORPTION VOLTAMMETRY FOR THE SIMULTANEOUS DETERMINATION OF NICKEL AND COBALT IN BIOLOGICAL-MATERIALS [J].
ADELOJU, SB ;
BOND, AM ;
BRIGGS, MH .
ANALYTICA CHIMICA ACTA, 1984, 164 (OCT) :181-194
[2]  
[Anonymous], 1985, STRIPPING ANAL PRINC
[3]   VOLTAMMETRIC DETERMINATION OF TRACES OF NICKEL(II) AT A CHEMICALLY MODIFIED ELECTRODE BASED ON DIMETHYLGLYOXIME-CONTAINING CARBON PASTE [J].
BALDWIN, RP ;
CHRISTENSEN, JK ;
KRYGER, L .
ANALYTICAL CHEMISTRY, 1986, 58 (08) :1790-1798
[4]   RAPID ANODIC-STRIPPING ANALYSIS WITH ULTRAMICROELECTRODES [J].
BARANSKI, AS .
ANALYTICAL CHEMISTRY, 1987, 59 (04) :662-666
[5]   FLOW-THROUGH CELL FOR CONTINUAL ONLINE MONITORING OF CADMIUM, COPPER, ANTIMONY, AND LEAD BY ANODIC-STRIPPING VOLTAMMETRY IN HIGHLY DENSE ZINC PLANT ELECTROLYTE [J].
BOND, AM ;
KNIGHT, RW ;
NEWMAN, OMG .
ANALYTICAL CHEMISTRY, 1988, 60 (21) :2445-2448
[6]   HYDROPHOBIC STRIPPING VOLTAMMETRY USING A LIPID-MODIFIED GLASSY-CARBON ELECTRODE [J].
CHASTEL, O ;
KAUFFMANN, JM ;
PATRIARCHE, GJ ;
CHRISTIAN, GD .
ANALYTICAL CHEMISTRY, 1989, 61 (02) :170-173
[7]   STRIPPING VOLTAMMETRY OF CHROMIUM(VI) AT A POLY(4-VINYLPYRIDINE)-COATED PLATINUM-ELECTRODE [J].
COX, JA ;
KULESZA, PJ .
ANALYTICA CHIMICA ACTA, 1983, 154 (NOV) :71-78
[8]   DETERMINATION OF HEAVY-METALS IN REAL SAMPLES BY ANODIC-STRIPPING VOLTAMMETRY WITH MERCURY MICROELECTRODES .2. APPLICATION TO RAIN AND SEA WATERS [J].
DANIELE, S ;
BALDO, MA ;
UGO, P ;
MAZZOCCHIN, GA .
ANALYTICA CHIMICA ACTA, 1989, 219 (01) :19-26
[9]   ANALYTICALLY USEFUL STRIPPING VOLTAMMETRIC BEHAVIOR OF TECHNETIUM AT A THENOYLTRIFLUOROACETONE-MODIFIED CARBON PASTE ELECTRODE [J].
DICK, R ;
RUF, H ;
ACHE, HJ .
ELECTROANALYSIS, 1989, 1 (01) :81-85
[10]   DIRECT DETERMINATION OF DISSOLVED COBALT AND NICKEL IN SEAWATER BY DIFFERENTIAL PULSE CATHODIC STRIPPING VOLTAMMETRY PRECEDED BY ADSORPTIVE COLLECTION OF CYCLOHEXANE-1,2-DIONE DIOXIME COMPLEXES [J].
DONAT, JR ;
BRULAND, KW .
ANALYTICAL CHEMISTRY, 1988, 60 (03) :240-244