STUDY OF NONCOVALENT ENZYME-INHIBITOR COMPLEXES AND METAL-BINDING STOICHIOMETRY OF MATRILYSIN BY ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY

被引:40
作者
FENG, R
CASTELHANO, AL
BILLEDEAU, R
YUAN, ZY
机构
[1] NATL RES COUNCIL CANADA,BIOTECHNOL RES INST,MONTREAL,PQ H4P 2R2,CANADA
[2] SYNTEX CANADA,MISSISSAUGA,ON,CANADA
关键词
D O I
10.1016/1044-0305(95)00548-X
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Electrospray ionization mass spectrometry (ESI-MS) was used to study the noncovalent metallo-enzyme-inhibitor complexes of matrilysin (a matrix metalloproteinase of mass 18,720 u) under gentle experimental conditions and to determine the metal ion association stoichiometries in both the free enzyme and the complexes. The metal association stoichiometries of the free matrilysin were found to be highly sensitive to solution pH changes. At pH 2.2 the enzyme existed as metal-free apo-matrilysin and was not capable of binding an inhibitor. At pH 4.5-7.0 the enzyme associated specifically with zinc and calcium cations and became active in inhibitor binding. Although the stoichiometries of the metal cofactors varied (zero to two zinc and/or calcium ions) in the free enzyme dependent on solution pH, the predominant form of the enzyme-inhibitor complexes in the pH range of 4.5-7.0, in contrast, always had the metal association stoichiometry of 2Zn + 2Ca, which was the same stoichiometry the most active free metallo-enzyme had at the optimal pH of 7. At the activity onset FH of 4.5 matrilysin existed mostly as apo-enzyme (but in a conformation different from the denatured one at pH 2.2) and bound to an inhibitor slowly (time constant similar to 2.5 min) to form the noncovalent metallo-enzyme-inhibitor complex. Of the two inhibitors studied, the one with the higher solution binding constant also produced larger ion signals for the noncovalent complex in the solvent-free gas phase, which pointed to the feasibility of the use of ESI-MS for inhibitor screening studies.
引用
收藏
页码:1105 / 1111
页数:7
相关论文
共 41 条
  • [1] DIRECT OBSERVATION OF A TERNARY COMPLEX BETWEEN THE DIMERIC ENZYME HIV-1 PROTEASE AND A SUBSTRATE-BASED INHIBITOR
    BACA, M
    KENT, SBH
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1992, 114 (10) : 3992 - 3993
  • [2] PRODUCTION, PURIFICATION, AND CHARACTERIZATION OF HUMAN MATRILYSIN (PUMP) FROM RECOMBINANT CHINESE-HAMSTER OVARY CELLS
    BARNETT, J
    STRAUB, K
    NGUYEN, B
    CHOW, J
    SUTTMAN, R
    THOMPSON, K
    TSING, S
    BENTON, P
    SCHATZMAN, R
    CHEN, M
    CHAN, H
    [J]. PROTEIN EXPRESSION AND PURIFICATION, 1994, 5 (01) : 27 - 36
  • [3] ION SPRAY INTERFACE FOR COMBINED LIQUID CHROMATOGRAPHY/ATMOSPHERIC PRESSURE IONIZATION MASS-SPECTROMETRY
    BRUINS, AP
    COVEY, TR
    HENION, JD
    [J]. ANALYTICAL CHEMISTRY, 1987, 59 (22) : 2642 - 2646
  • [4] WEIGHING NAKED PROTEINS - PRACTICAL, HIGH-ACCURACY MASS MEASUREMENT OF PEPTIDES AND PROTEINS
    CHAIT, BT
    KENT, SBH
    [J]. SCIENCE, 1992, 257 (5078) : 1885 - 1894
  • [5] SURFACE-INDUCED DISSOCIATION OF MULTIPLY PROTONATED PROTEINS
    CHORUSH, RA
    LITTLE, DP
    BEU, SC
    WOOD, TD
    MCLAFFERTY, FW
    [J]. ANALYTICAL CHEMISTRY, 1995, 67 (06) : 1042 - 1046
  • [6] PROBING CONFORMATIONAL-CHANGES IN PROTEINS BY MASS-SPECTROMETRY
    CHOWDHURY, SK
    KATTA, V
    CHAIT, BT
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1990, 112 (24) : 9012 - 9013
  • [7] Covey T R, 1988, Rapid Commun Mass Spectrom, V2, P249, DOI 10.1002/rcm.1290021111
  • [8] STRUCTURAL CHARACTERIZATION OF PROTEIN TRYPTIC PEPTIDES VIA LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY AND COLLISION-INDUCED DISSOCIATION OF THEIR DOUBLY CHARGED MOLECULAR-IONS
    COVEY, TR
    HUANG, EC
    HENION, JD
    [J]. ANALYTICAL CHEMISTRY, 1991, 63 (13) : 1193 - 1200
  • [9] BIOCHEMICAL-CHARACTERIZATION OF MATRILYSIN - ACTIVATION CONFORMS TO THE STEPWISE MECHANISMS PROPOSED FOR OTHER MATRIX METALLOPROTEINASES
    CRABBE, T
    WILLENBROCK, F
    EATON, D
    HYNDS, P
    CARNE, AF
    MURPHY, G
    DOCHERTY, AJP
    [J]. BIOCHEMISTRY, 1992, 31 (36) : 8500 - 8507
  • [10] ANALYSIS OF ANTIBODIES AND OTHER LARGE GLYCOPROTEINS IN THE MASS RANGE OF 150000-200000 DA BY ELECTROSPRAY IONIZATION MASS-SPECTROMETRY
    FENG, R
    KONISHI, Y
    [J]. ANALYTICAL CHEMISTRY, 1992, 64 (18) : 2090 - 2095