DETERMINATION OF TRACE-ELEMENTS IN SEA-WATER BY FLOW-INJECTION ANODIC-STRIPPING VOLTAMMETRY PRECEDED BY IMMOBILIZED QUINOLIN-8-OL SILICA-GEL PRECONCENTRATION

被引:22
作者
DAIH, BJ
HUANG, HJ
机构
[1] Department of Chemistry, National Sun Yat-sen University, Kaohsiung
关键词
ANODIC STRIPPING VOLTAMMETRY; FLOW SYSTEM; PRECONCENTRATION; SEA WATER; TRACE METALS; WATERS;
D O I
10.1016/0003-2670(92)85098-Q
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Procedures based on the application of immobilized quinolin-8-ol silica gel and stripping voltammetry were developed for the determination of copper, lead, cadmium, bismuth, indium and zinc in sea water. As two concentration steps are involved, better sensitivity and lower detection limits could be achieved with the application of smaller sample volumes. The feasibility and reliability of the developed procedures were confirmed by the analysis of a near-shore sea-water sample and CASS-2 reference sea water.
引用
收藏
页码:245 / 252
页数:8
相关论文
共 30 条
[1]   SIMULTANEOUS MULTIELEMENT DETERMINATION OF TRACE-METALS IN SEA-WATER BY INDUCTIVELY-COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY AFTER COPRECIPITATION WITH GALLIUM [J].
AKAGI, T ;
FUWA, K ;
HARAGUCHI, H .
ANALYTICA CHIMICA ACTA, 1985, 177 :139-151
[2]   PRECONCENTRATION BY COPRECIPITATION OF SUBMICROGRAM AMOUNTS OF COPPER AND MANGANESE WITH 8-QUINOLINOL AND DIRECT ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY OF THE PRECIPITATES [J].
AKATSUKA, K ;
ATSUYA, I .
ANALYTICA CHIMICA ACTA, 1987, 202 :223-230
[3]   DETERMINATION OF SILVER IN SEA-WATER BY COPRECIPITATION WITH COBALT PYRROLIDINEDITHIOCARBAMATE AND ZEEMAN GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY [J].
BLOOM, NS ;
CRECELIUS, EA .
ANALYTICA CHIMICA ACTA, 1984, 156 (JAN) :139-145
[4]   STRATEGY FOR TRACE-METAL DETERMINATION IN SEAWATER BY ANODIC-STRIPPING VOLTAMMETRY USING A COMPUTERIZED MULTI-TIME-DOMAIN MEASUREMENT METHOD [J].
BOND, AM ;
HERITAGE, ID ;
THORMANN, W .
ANALYTICAL CHEMISTRY, 1986, 58 (06) :1063-1066
[5]   DETERMINATION OF VERY LOW-LEVELS OF SELENIUM(IV) IN SEA-WATER BY DIFFERENTIAL-PULSE CATHODIC STRIPPING VOLTAMMETRY AFTER EXTRACTION OF THE 3,3'-DIAMINOBENZIDINE PIAZSELENOL [J].
BREYER, P ;
GILBERT, BP .
ANALYTICA CHIMICA ACTA, 1987, 201 :33-41
[6]   A SOLVENT-EXTRACTION METHOD FOR THE COLORIMETRIC DETERMINATION OF NANOMOLAR CONCENTRATIONS OF SILICIC-ACID IN SEAWATER [J].
BRZEZINSKI, MA ;
NELSON, DM .
MARINE CHEMISTRY, 1986, 19 (02) :139-151
[7]   DETERMINATION OF HEAVY-METALS IN REAL SAMPLES BY ANODIC-STRIPPING VOLTAMMETRY WITH MERCURY MICROELECTRODES .2. APPLICATION TO RAIN AND SEA WATERS [J].
DANIELE, S ;
BALDO, MA ;
UGO, P ;
MAZZOCCHIN, GA .
ANALYTICA CHIMICA ACTA, 1989, 219 (01) :19-26
[8]   DETERMINATION OF HEAVY-METALS IN REAL SAMPLES BY ANODIC-STRIPPING VOLTAMMETRY WITH MERCURY MICROELECTRODES .1. APPLICATION TO WINE [J].
DANIELE, S ;
BALDO, MA ;
UGO, P ;
MAZZOCCHIN, GA .
ANALYTICA CHIMICA ACTA, 1989, 219 (01) :9-18
[9]   DIRECT DETERMINATION OF DISSOLVED COBALT AND NICKEL IN SEAWATER BY DIFFERENTIAL PULSE CATHODIC STRIPPING VOLTAMMETRY PRECEDED BY ADSORPTIVE COLLECTION OF CYCLOHEXANE-1,2-DIONE DIOXIME COMPLEXES [J].
DONAT, JR ;
BRULAND, KW .
ANALYTICAL CHEMISTRY, 1988, 60 (03) :240-244
[10]   SILICA-GEL AS AN INSOLUBLE CARRIER FOR PREPARATION OF SELECTIVE CHROMATOGRAPHIC ADSORBENTS - PREPARATION OF 8-HYDROXYQUINOLINE SUBSTITUTED SILICA-GEL FOR CHELATION CHROMATOGRAPHY OF SOME TRACE METALS [J].
HILL, JM .