AN AUTOMATED SAMPLE CLEANUP APPARATUS USED IN THE PROCEDURE FOR MEASURING POLYCHLORINATED DIBENZO-P-DIOXINS, DIBENZOFURANS, AND ORTHOUNSUBSTITUTED (PLANAR) BIPHENYLS IN HUMAN SERUM AND ADIPOSE-TISSUE

被引:16
作者
TURNER, WE
ISAACS, SG
PATTERSON, DG
机构
[1] Division of Environmental Health Laboratory Sciences, National Center for Environmental Health and Injury Control, Centers for Disease Control, Atlanta, GA 30333
关键词
AUTOMATED SAMPLE CLEANUP APPARATUS; HUMAN SERUM AND ADIPOSE TISSUE; PCDDS; PCDFS; PLANAR PCBS;
D O I
10.1016/0045-6535(92)90070-8
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
An improved automated sample cleanup apparatus used in the Centers for Disease Control (CDC) procedure for measuring polychlorinated dibenzo-p-dioxins (PCDDs), dibenzofurans (PCDFs), and ortho-unsubstituted or planar biphenyls (planar PCBs) in serum and adipose tissue has been developed. Compared to our prototype model, this device is more versatile, easier to use, and has reduced the time required to perform the first part of the procedure from 20 to 4 h.
引用
收藏
页码:805 / 810
页数:6
相关论文
共 7 条
[1]   AUTOMATED APPARATUS FOR THE EXTRACTION AND ENRICHMENT OF 2,3,7,8-TETRACHLORODIBENZO-PARA-DIOXIN IN HUMAN ADIPOSE-TISSUE [J].
LAPEZA, CR ;
PATTERSON, DG ;
LIDDLE, JA .
ANALYTICAL CHEMISTRY, 1986, 58 (04) :713-716
[2]   GAS-CHROMATOGRAPHIC MASS-SPECTROMETRIC ANALYSIS OF HUMAN-SERUM FOR NON-ORTHO (COPLANAR) AND ORTHO SUBSTITUTED POLYCHLORINATED-BIPHENYLS USING ISOTOPE-DILUTION MASS-SPECTROMETRY [J].
PATTERSON, DG ;
LAPEZA, CR ;
BARNHART, ER ;
GROCE, DF ;
BURSE, VW .
CHEMOSPHERE, 1989, 19 (1-6) :127-134
[3]   HIGH-RESOLUTION GAS-CHROMATOGRAPHIC HIGH-RESOLUTION MASS-SPECTROMETRIC ANALYSIS OF HUMAN-SERUM ON A WHOLE-WEIGHT AND LIPID BASIS FOR 2,3,7,8-TETRACHLORODIBENZO-P-DIOXIN [J].
PATTERSON, DG ;
HAMPTON, L ;
LAPEZA, CR ;
BELSER, WT ;
GREEN, V ;
ALEXANDER, L ;
NEEDHAM, LL .
ANALYTICAL CHEMISTRY, 1987, 59 (15) :2000-2005
[4]   THE ANALYTICAL METHODOLOGY AND METHOD PERFORMANCE FOR THE DETERMINATION OF 2,3,7,8-TCDD IN SERUM FOR THE VIETNAM VETERAN AGENT ORANGE VALIDATION-STUDY, THE RANCH HAND VALIDATION AND HALF-LIFE STUDIES, AND SELECTED NIOSH WORKER STUDIES [J].
PATTERSON, DG ;
TURNER, WE ;
ALEXANDER, LR ;
ISAACS, S ;
NEEDHAM, LL .
CHEMOSPHERE, 1989, 18 (1-6) :875-882
[5]   HIGH-RESOLUTION GAS CHROMATOGRAPHIC/HIGH-RESOLUTION MASS-SPECTROMETRIC ANALYSIS OF HUMAN ADIPOSE-TISSUE FOR 2,3,7,8-TETRACHLORODIBENZO-PARA-DIOXIN [J].
PATTERSON, DG ;
HOLLER, JS ;
LAPEZA, CR ;
ALEXANDER, LR ;
GROCE, DF ;
OCONNOR, RC ;
SMITH, SJ ;
LIDDLE, JA ;
NEEDHAM, LL .
ANALYTICAL CHEMISTRY, 1986, 58 (04) :705-713
[6]   DETERMINATION OF PART-PER-TRILLION LEVELS OF POLYCHLORINATED DIBENZOFURANS AND DIOXINS IN ENVIRONMENTAL-SAMPLES [J].
SMITH, LM ;
STALLING, DL ;
JOHNSON, JL .
ANALYTICAL CHEMISTRY, 1984, 56 (11) :1830-1842
[7]   AN AUTOMATED SAMPLE CLEANUP APPARATUS USED IN THE PROCEDURE FOR MEASURING POLYCHLORINATED DIBENZO-P-DIOXINS, DIBENZOFURANS, AND ORTHOUNSUBSTITUTED (PLANAR) BIPHENYLS IN HUMAN SERUM AND ADIPOSE-TISSUE [J].
TURNER, WE ;
ISAACS, SG ;
PATTERSON, DG .
CHEMOSPHERE, 1992, 25 (06) :805-810