IMPROVED QUANTIFICATION IN SECONDARY-ION MASS-SPECTROMETRY DETECTING MCS+ MOLECULAR-IONS

被引:62
作者
GNASER, H [1 ]
机构
[1] UNIV KAISERSLAUTERN,INST OBERFLACHEN & SCHICHTANALYT,D-67665 KAISERSLAUTERN,GERMANY
来源
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS | 1994年 / 12卷 / 02期
关键词
D O I
10.1116/1.579262
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Molecular secondary ions composed of a sample atom M and a resputtered Cs+ projectile (MCs+) are successfully used for the quantification of secondary-ion mass spectrometry (SIMS) data. For a variety of different specimens it is demonstrated that the yields of these rather ubiquitous species exhibit little or no dependence on sample composition (matrix effect) even in the presence of electronegative elements and are thus well suited for quantitative SIMS evaluation. Specifically, for series of binary and ternary systems (a-Si:H, a-SiGe:H, a-SiC:H, and HCN) composition independent relative sensitivity factors could be established; thus, quantification by means of a single standard is feasible. Furthermore, from the correlation of the measured MCs+ secondary ion intensities relative sensitivity factors (and hence concentrations) can directly be derived, i.e., without any standard. The applicability of this quantification scheme is exemplified for a AlGaAs/GaAs multilayer structure and for the Ga focused ion beam implantation in InP. The results indicate that utilizing MCs+ molecular ions an accurate quantification of major components by SIMS is possible.
引用
收藏
页码:452 / 456
页数:5
相关论文
共 25 条
[1]  
[Anonymous], 1987, SURF INTERFACE ANAL
[3]   FLUENCE DEPENDENT CONCENTRATION OF LOW-ENERGY GA IMPLANTED IN SI [J].
GNASER, H ;
STELTMANN, J ;
OECHSNER, H .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1993, 80-1 (pt 2) :110-114
[4]   NOVEL DETECTION SCHEME FOR THE ANALYSIS OF HYDROGEN AND HELIUM BY SECONDARY ION MASS-SPECTROMETRY [J].
GNASER, H ;
OECHSNER, H .
SURFACE AND INTERFACE ANALYSIS, 1991, 17 (09) :646-649
[5]   SIMS DEPTH PROFILE ANALYSIS USING MCS+ MOLECULAR-IONS [J].
GNASER, H ;
OECHSNER, H .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1991, 341 (1-2) :54-56
[6]   COMPARATIVE SIMS AND SNMS ANALYSES OF AMORPHOUS-SEMICONDUCTOR THIN-FILMS [J].
GNASER, H ;
BOCK, W ;
OECHSNER, H ;
BHATTACHARAYYA, TK .
APPLIED SURFACE SCIENCE, 1993, 70-1 (1 -4 pt A) :44-48
[7]   HYDROGEN ANALYSIS BY SECONDARY ION MASS-SPECTROMETRY USING HCS+ IONS [J].
GNASER, H ;
OECHSNER, H .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1992, 64 (1-4) :646-649
[8]  
GNASER H, IN PRESS SURF INTERF
[9]  
GNASER H, IN PRESS SURF SCI
[10]  
HAAG M, UNPUB