35-MM FILM SCANNER AS AN INTRAORAL DENTAL RADIOGRAPH DIGITIZER .2. EFFECTS OF BRIGHTNESS AND CONTRAST ADJUSTMENTS

被引:17
作者
SHROUT, MK
POTTER, BJ
YURGALAVAGE, HM
HILDEBOLT, CF
VANNIER, MW
机构
[1] EDWARD MALLINCKRODT INST RADIOL, ST LOUIS, MO 63110 USA
[2] WASHINGTON UNIV, SCH MED, ST LOUIS, MO 63110 USA
来源
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY | 1993年 / 76卷 / 04期
关键词
D O I
10.1016/0030-4220(93)90021-U
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Typical 35-mm slide scanners use a photodiode array and software that allows for digital and analog controls that are manually adjustable. The digital controls provide brightness and contrast adjustments, whereas corresponding analog controls adjust the exposure time and black level that determines the clamping level of the charge-coupled device for the maximum black in the image. The objective of this study was to determine the effects of these controls on the radiometric data of intraoral dental radiograph images, to establish recommended settings, and to set specific standard guidelines for the digitization process. Three approaches were used. The results of this study demonstrate that brightness and contrast control alterations on the digitizer produces different optical densities and modulation transfer function values. The impact of these results is unresolved yet must be considered in analysis on quantitative radiometric studies.
引用
收藏
页码:510 / 518
页数:9
相关论文
共 16 条
[1]   COMPUTER-ASSISTED DENSITOMETRIC IMAGE-ANALYSIS IN PERIODONTAL RADIOGRAPHY - A METHODOLOGICAL STUDY [J].
BRAGGER, D ;
PASQUALI, L ;
RYLANDER, H ;
CARNES, D ;
KORNMAN, KS .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1988, 15 (01) :27-37
[2]   COMPUTER-ASSISTED DENSITOMETRIC IMAGE-ANALYSIS (CADIA) FOR THE ASSESSMENT OF ALVEOLAR BONE-DENSITY CHANGES IN FURCATIONS [J].
BRAGGER, U ;
PASQUALI, L ;
WEBER, H ;
KORNMAN, KS .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1989, 16 (01) :46-52
[3]   A PRACTICAL METHOD TO MEASURE THE MTF OF CT SCANNERS [J].
DROEGE, RT ;
MORIN, RL .
MEDICAL PHYSICS, 1982, 9 (05) :758-759
[4]   A PRACTICAL METHOD TO ROUTINELY MONITOR RESOLUTION IN DIGITAL IMAGES [J].
DROEGE, RT .
MEDICAL PHYSICS, 1983, 10 (03) :337-343
[5]   AN EXPERIMENTAL-STUDY OF NEW DIAGNOSTIC METHODS FOR THE EXAMINATION OF OSSEOUS LESIONS IN THE TEMPOROMANDIBULAR-JOINT [J].
ENGELKE, W ;
RUTTIMANN, UE ;
TSUCHIMOCHI, M ;
BACHER, JD .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1992, 73 (03) :348-359
[6]   DIGITAL IMAGE-PROCESSING OF PERIAPICAL RADIOGRAPHS [J].
FUJITA, M ;
KODERA, Y ;
OGAWA, M ;
WADA, T ;
DOI, K .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1988, 65 (04) :490-494
[7]   DETECTABILITY OF ARTIFICIAL MARGINAL BONE-LESIONS AS A FUNCTION OF LESION DEPTH - A COMPARISON BETWEEN SUBTRACTION RADIOGRAPHY AND CONVENTIONAL RADIOGRAPHIC TECHNIQUE [J].
GRONDAHL, K ;
KULLENDORFF, B ;
STRID, KG ;
GRONDAHL, HG ;
HENRIKSON, CO .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1988, 15 (03) :156-162
[8]  
Hausmann E, 1985, J Periodontol, V56 Suppl 11S, P4, DOI 10.1902/jop.1985.56.11s.4
[9]   QUANTITATIVE-EVALUATION OF DIGITAL DENTAL RADIOGRAPH IMAGING-SYSTEMS [J].
HILDEBOLT, CF ;
VANNIER, MW ;
PILGRAM, TK ;
SHROUT, MK .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 1990, 70 (05) :661-668
[10]   DIAGNOSING PERIAPICAL BONE-LESIONS ON RADIOGRAPHS BY MEANS OF TEXTURE ANALYSIS [J].
MOL, A ;
DUNN, SM ;
VANDERSTELT, PF .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1992, 73 (06) :746-750