DETECTION OF X-RAYS WITH A FIBEROPTIC INTERFEROMETRIC SENSOR

被引:4
作者
BARONE, F
BERNINI, U
CONTI, M
DELGUERRA, A
DIFIORE, L
GAMBACCINI, M
LIUZZI, R
MILANO, L
RUSSO, G
RUSSO, P
SALVATO, M
机构
[1] IST FIS NUCL, I-80125 NAPLES, ITALY
[2] UNIV FERRARA, DIPARTIMENTO FIS, I-44100 FERRARA, ITALY
[3] IST NAZL FIS NUCL, I-44100 FERRARA, ITALY
来源
APPLIED OPTICS | 1993年 / 32卷 / 07期
关键词
X RAYS; FIBEROPTIC SENSORS; SYNCHROTRON RADIATION;
D O I
10.1364/AO.32.001229
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A fiber-optic Mach-Zehnder interferometer was used for x-ray detection. A single-mode, polarization-preserving silica fiber is exposed to a high-flux x-ray beam (x-ray tube for diagnostic radiology, 30 kV, 16.8-keV average energy, 17-40-mA anodic current), modulated at f = 9 Hz by a chopper with steel blades. The energy absorbed produces a modulated temperature rise that induces a phase shift in the propagation of a He-Ne laser beam with respect to the unirradiated arm of the interferometer. We measured the linearity of the temperature rise with the energy released to the fiber and the linearity of the peak amplitude at frequency f in the power spectrum of the interferometric signal with the anodic current of the x-ray tube. A possible application of this technique to synchrotron radiation monitoring is discussed.
引用
收藏
页码:1229 / 1233
页数:5
相关论文
共 18 条
[1]  
Attix F.H., 1986, INTRO RADIOLOGICAL P, P607, DOI 10.1002/9783527617135
[2]  
BARONE F, 1991, P SOC PHOTO-OPT INS, V1584, P304, DOI 10.1117/12.50953
[3]   IMPLEMENTATION AND TEST OF A SYNCHROTRON RADIATION POSITION MONITOR AT A USER BEAM LINE [J].
BRODSKY, EL ;
KLEMAN, KJ ;
ROGERS, G ;
RIOUX, D ;
PATEL, R ;
HOCHST, H .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01) :519-522
[4]   FIBER OPTIC DOSIMETER ON THE NAVIGATIONAL TECHNOLOGY SATELLITE-2 [J].
EVANS, BD ;
SIGEL, GH ;
LANGWORTHY, JB ;
FARADAY, BJ .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1978, 25 (06) :1619-1624
[5]   THEORY FOR THE PHOTOACOUSTIC RESPONSE TO X-RAY ABSORPTION [J].
GARCIA, ME ;
PASTOR, GM ;
BENNEMANN, KH .
PHYSICAL REVIEW LETTERS, 1988, 61 (01) :121-124
[6]   OPTICAL FIBER SENSOR TECHNOLOGY [J].
GIALLORENZI, TG ;
BUCARO, JA ;
DANDRIDGE, A ;
SIGEL, GH ;
COLE, JH ;
RASHLEIGH, SC ;
PRIEST, RG .
IEEE JOURNAL OF QUANTUM ELECTRONICS, 1982, 18 (04) :626-665
[7]  
HOSHI M, 1986, KEK4 NAT LAB HIGH EN, P313
[8]  
JACKSON DA, 1980, OPT LETT, V5, P1339
[9]   X-RAY, SOFT-X-RAY, AND VUV BEAM POSITION MONITOR [J].
KARLIN, BA ;
COWAN, PL ;
WOICIK, JC .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01) :526-529
[10]   PHOTOACOUSTIC DETECTOR FOR SYNCHROTRON-RADIATION RESEARCH [J].
MASUJIMA, T ;
YOSHIDA, H ;
KAWATA, H ;
AMEMIYA, Y ;
KATSURA, T ;
ANDO, M ;
NANBA, T ;
FUKUI, K ;
WATANABE, M .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (07) :2318-2320