MASS MEASUREMENT ACCURACY OF MATRIX-ASSISTED LASER-DESORBED BIOMOLECULES - A FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY STUDY

被引:28
作者
SOLOUKI, T [1 ]
GILLIG, KJ [1 ]
RUSSELL, DH [1 ]
机构
[1] TEXAS A&M UNIV, DEPT CHEM, COLL STN, TX 77843 USA
关键词
D O I
10.1002/rcm.1290080106
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The use of binary matrices and internal calibrants to improve the mass measurement accuracy in matrix-assisted laser desorption ionization (MALDI) with Fourier-transform ion cyclotron resonance (FTICR) mass spectrometry is described. Binary matrices enhance the analyte ion yield and enable a complete MALDI-FTICR mass spectrum to be obtained from a single laser shot. The advantage of single-laser-shot data acquisition is that it eliminates line-broadening due to shot-to-shot frequency variations. It is shown that unresolved product ions, mainly due to loss of H2O and/or NH3, shift the centroid of an unresolved multi-component peak. A mass measurement accuracy of 12 ppm was obtained for the bovine insulin [M + H]+ ion using melittin as an internal calibrant.
引用
收藏
页码:26 / 31
页数:6
相关论文
共 38 条
[11]   ION DETECTION BY FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE - THE EFFECT OF INITIAL RADIAL-VELOCITY ON THE COHERENT ION PACKET [J].
HANSON, CD ;
KERLEY, EL ;
CASTRO, ME ;
RUSSELL, DH .
ANALYTICAL CHEMISTRY, 1989, 61 (18) :2040-2046
[12]   HIGH-RESOLUTION ELECTROSPRAY MASS-SPECTRA OF LARGE MOLECULES [J].
HENRY, KD ;
QUINN, JP ;
MCLAFFERTY, FW .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1991, 113 (14) :5447-5449
[13]   FOURIER-TRANSFORM MASS-SPECTROMETRY OF LARGE MOLECULES BY ELECTROSPRAY IONIZATION [J].
HENRY, KD ;
WILLIAMS, ER ;
WANG, BH ;
MCLAFFERTY, FW ;
SHABANOWITZ, J ;
HUNT, DF .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1989, 86 (23) :9075-9078
[14]   STRUCTURAL CHARACTERIZATION OF NORMAL AND MODIFIED OLIGONUCLEOTIDES BY MATRIX-ASSISTED LASER DESORPTION FOURIER-TRANSFORM MASS-SPECTROMETRY [J].
HETTICH, R ;
BUCHANAN, M .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1991, 2 (05) :402-412
[15]   MATRIX-ASSISTED LASER DESORPTION IONIZATION WITH A MAGNETIC MASS-SPECTROMETER [J].
HILL, JA ;
ANNAN, RS ;
BIEMANN, K .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1991, 5 (09) :395-399
[16]   A BASIC PROGRAM FOR CALCULATING PRECISE, AVERAGE AND NOMINAL MOLECULAR-WEIGHTS FROM ELEMENTAL FORMULAS [J].
HILL, R ;
FALES, H ;
MCNEIL, C ;
MACFARLANE, R .
BIOMEDICAL MASS SPECTROMETRY, 1983, 10 (09) :505-506
[17]   ELECTROSPRAY IONIZATION IN THE STRONG MAGNETIC-FIELD OF A FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETER [J].
HOFSTADLER, SA ;
LAUDE, DA .
ANALYTICAL CHEMISTRY, 1992, 64 (05) :569-572
[18]   DETERMINATION OF MOLECULAR COMPOSITIONS ON A QUADRUPOLE MASS-SPECTROMETER BY PULSED POSITIVE-ION NEGATIVE-ION CHEMICAL IONIZATION MASS-SPECTROMETRY [J].
HUNT, DF ;
STAFFORD, GC ;
SHABANOWITZ, J ;
CROW, FW .
ANALYTICAL CHEMISTRY, 1977, 49 (12) :1884-1884
[19]   MATRIX-ASSISTED ULTRAVIOLET-LASER DESORPTION OF NONVOLATILE COMPOUNDS [J].
KARAS, M ;
BACHMANN, D ;
BAHR, U ;
HILLENKAMP, F .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1987, 78 :53-68
[20]  
KINSEL GR, IN PRESS NUCLEAR INS