REDUCED-PRESSURE MICROWAVE-INDUCED PLASMA MASS-SPECTROMETRIC DETECTION OF PHOSPHORUS AND SULFUR IN GAS-CHROMATOGRAPHIC ELUATES

被引:25
作者
STORY, WC [1 ]
OLSON, LK [1 ]
SHEN, WL [1 ]
CREED, JT [1 ]
CARUSO, JA [1 ]
机构
[1] UNIV CINCINNATI,DEPT CHEM,CINCINNATI,OH 45221
关键词
Capillary gas chromatography; Phosphorus detection; Reduced-pressure helium microwave-induced plasma mass spectrometry; Reduced-pressure nitrogen microwave-induced plasma mass spectrometry; Sulphur detection;
D O I
10.1039/ja9900500467
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The determination of phosphorus and sulphur at trace levels is not possible by conventional atmospheric pressure plasma mass spectrometry because of high background signals at m/z= 31 (14N16OH + )and m/z= 32 (16O2 + ). The reduced-pressure plasmas decrease the background at the major isotopes of phosphorus and sulphur such that sub-nanogram detection is possible. The use of reduced-pressure helium and nitrogen microwave-induced plasmas for the determination of phosphorus and sulphur is discussed. With a helium plasma, the detection limit for phosphorus in triethyl phosphite ranges from 1 to 90 ng depending on the amount of torch cooling. Using a nitrogen plasma, sub-nanogram detection limits for phosphorus and sulphur in two organophosphorus pesticides were obtained.
引用
收藏
页码:467 / 470
页数:4
相关论文
共 21 条
[1]   LOW PRESSURE EMISSION SPECTROMETRIC DETERMINATION OF PART-PER-BILLION RESIDUE LEVELS OF ORGANOPHOSPHORUS INSECTICIDES [J].
BACHE, CA ;
LISK, DJ .
ANALYTICAL CHEMISTRY, 1966, 38 (12) :1757-&
[2]   DETERMINATION OF IODINATED HERBICIDE RESIDUES AND METABOLITES BY GAS CHROMATOGRAPHY USING EMISSION SPECTROMETRIC DETECTOR [J].
BACHE, CA ;
LISK, DJ .
ANALYTICAL CHEMISTRY, 1966, 38 (06) :783-&
[3]   DETERMINATION OF ORGANOPHOSPHORUS INSECTICIDE RESIDUES USING EMISSION SPECTROMETRIC DETECTOR [J].
BACHE, CA ;
LISK, DJ .
ANALYTICAL CHEMISTRY, 1965, 37 (12) :1477-&
[4]  
BACHE CA, 1967, ANAL CHEM, V39, P787
[5]   LOW-PRESSURE HELIUM MICROWAVE-INDUCED PLASMA MASS-SPECTROMETRY FOR THE DETECTION OF HALOGENATED GAS-CHROMATOGRAPHIC EFFLUENTS [J].
CREED, JT ;
DAVIDSON, TM ;
SHEN, WL ;
CARUSO, JA .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1990, 5 (02) :109-113
[6]   HELIUM SOURCE MICROWAVE-INDUCED PLASMA MASS-SPECTROMETRIC DETECTION IN THE ANALYSIS OF GAS-CHROMATOGRAPHIC ELUATES [J].
CREED, JT ;
MOHAMAD, AH ;
DAVIDSON, TM ;
ATAMAN, G ;
CARUSO, JA .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1988, 3 (06) :923-926
[7]   A LOW-PRESSURE BEENAKKER-TYPE MICROWAVE-INDUCED HELIUM PLASMA SOURCE AS A SIMULTANEOUS MULTIELEMENT GAS-CHROMATOGRAPHIC DETECTOR [J].
EVANS, JC ;
OLSEN, KB ;
SKLAREW, DS .
ANALYTICA CHIMICA ACTA, 1987, 194 :247-260
[8]  
FIOR RL, 1989, AM LAB, V21, P40
[9]   AN INTERNALLY TUNED TM010 MICROWAVE RESONANT CAVITY FOR MODERATE POWER MICROWAVE-INDUCED PLASMAS [J].
HAAS, DL ;
CARNAHAN, JW ;
CARUSO, JA .
APPLIED SPECTROSCOPY, 1983, 37 (01) :82-85
[10]  
HORLICK G, 1987, INDUCTIVELY COUPLED