ATOMIC-ABSORPTION SPECTROMETRIC DETECTION OF BIOTIN-CYMANTRENE AS A METALLO-TRACER FOR THE AVIDIN-BIOTIN SYSTEM

被引:10
作者
REMY, I [1 ]
BROSSIER, P [1 ]
机构
[1] FAC PHARM DIJON,UNITE IMMUNOANAL,7 BD JEANNE ARC,F-21033 DIJON,FRANCE
关键词
AVIDIN; BIOTIN; CYMANTRENE; IMMUNOASSAY; ZEEMAN ATOMIC ABSORPTION SPECTROMETER;
D O I
10.1039/an9931801021
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Biotin-cyclopentadienylmanganese tricarbonyl (biotin-cymantrene; biotin-Cy) is proposed as a universal metallo-tracer for immunoassays. Associated with the possibility of detecting this type of label (organometallic moieties) along with different analytical procedures, this reagent appears to be a universal system with the advantages of being inexpensive, stable and directly detected (no substrate is required). The optimum conditions for detecting the organometallic label biotin-Cy with a Zeeman atomic absorption spectrometer and the affinity of biotin-Cy for the streptavidin ligand immobilized on the walls of microtitre plates, wells or tubes are described. The results obtained demonstrate the possibility of assaying a wide range of clinical parameters because the detection limit of biotin-Cy is about 1 pg per assay. Based on the competition between immobilized bovine serum albumin adsorbed on the wall and free bovine serum albumin for specific polyclonal antibodies, the streptavidin-metallo-biotin system was tested on a competitive immunoassay model and a satisfactory calibration graph was obtained.
引用
收藏
页码:1021 / 1025
页数:5
相关论文
共 25 条
[11]   THE USE OF METALLOCENIC ESTERS OF N-HYDROXYSUCCINIMIDE FOR METALLOHAPTEN SYNTHESIS [J].
LAVASTRE, I ;
BESANCON, J ;
BROSSIER, P ;
MOISE, C .
APPLIED ORGANOMETALLIC CHEMISTRY, 1991, 5 (03) :143-149
[12]  
LAVASTRE I, 1991, THESIS U BOURGOGNE
[13]  
MARIET F, 1990, RES COMMUN CHEM PATH, V68, P251
[14]  
MONTAGNE P, 1990, ANN BIOL CLIN-PARIS, V48, P459
[15]   STREPTAVIDIN-BASED MACROMOLECULAR COMPLEX LABELED WITH A EUROPIUM CHELATOR SUITABLE FOR TIME-RESOLVED FLUORESCENCE IMMUNOASSAY APPLICATIONS [J].
MORTON, RC ;
DIAMANDIS, EP .
ANALYTICAL CHEMISTRY, 1990, 62 (17) :1841-1845
[16]  
Ngo TT., 1987, ELECTROCHEMICAL SENS
[17]  
ODELL WD, 1969, ACTA ENDOCR-COP S, V140, P54
[18]  
REMY I, J PHARM BIOMED ANAL, V9, P965
[19]   FOURIER-TRANSFORM INFRARED SPECTROSCOPIC METHOD FOR THE QUANTITATIVE TRACE ANALYSIS OF TRANSITION-METAL CARBONYL-LABELED BIOLIGANDS [J].
SALMAIN, M ;
VESSIERES, A ;
JAOUEN, G ;
BUTLER, IS .
ANALYTICAL CHEMISTRY, 1991, 63 (20) :2323-2329
[20]   CARBONYLMETALLOIMMUNOASSAY (CMIA) A NEW TYPE OF NONRADIOISOTOPIC IMMUNOASSAY - PRINCIPLES AND APPLICATION TO PHENOBARBITAL ASSAY [J].
SALMAIN, M ;
VESSIERES, A ;
BROSSIER, P ;
BUTLER, IS ;
JAOUEN, G .
JOURNAL OF IMMUNOLOGICAL METHODS, 1992, 148 (1-2) :65-75