INTERCOMPARISON OF NO2 MEASUREMENT TECHNIQUES

被引:100
作者
FEHSENFELD, FC
DRUMMOND, JW
ROYCHOWDHURY, UK
GALVIN, PJ
WILLIAMS, EJ
BUHR, MP
PARRISH, DD
HUBLER, G
LANGFORD, AO
CALVERT, JG
RIDLEY, BA
GRAHEK, F
HEIKES, BG
KOK, GL
SHETTER, JD
WALEGA, JG
ELSWORTH, CM
NORTON, RB
FAHEY, DW
MURPHY, PC
HOVERMALE, C
MOHNEN, VA
DEMERJIAN, KL
MACKAY, GI
SCHIFF, HI
机构
[1] UNIV COLORADO, NOAA, COOPERAT INST RES ENVIRONM SCI, BOULDER, CO 80309 USA
[2] UNISEARCH ASSOCIATES INC, CONCORD, ONTARIO, CANADA
[3] SUNY ALBANY, ATMOSPHER SCI RES CTR, ALBANY, NY 12222 USA
[4] NEW YORK STATE DEPT ENVIRONM CONSERVAT, DIV AIR RESOURCES, ALBANY, NY 12201 USA
[5] NATL CTR ATMOSPHER RES, BOULDER, CO 80307 USA
[6] CSIRO, DIV ATMOSPHER PHYS, ASPENDALE, VIC, AUSTRALIA
[7] CANADIAN INST RES ATMOSPHER CHEM, N YORK, ONTARIO, CANADA
关键词
D O I
10.1029/JD095iD04p03579
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
1) The photolysis/chemiluminescence (PC) instrument, 2) the tunable diode laser absorption spectrometer (TDLAS), and 3) the Luminox instrument. Calibrated mixtures of NO2 in air and NO2 with possible interferants (HNO3, peroxyacetyl nitrate (PAN), H2 O2, n-propyl nitrate, and O3) were provided in simultaneous tests. 1) For NO2 levels above 2 parts per billion by volume (ppbv), similar results were obtained for all instruments; 2) below 2 ppbv, the expected interferences from ozone and PAN influenced the NO2 measurements made using the Luminox instruments; 3) the ozone interference on the Luminox instruments was removed by an ozone scrubber placed in the sampled air stream of the Luminox instrument; 4) although no interferences were identified for the TDLAS technique, care must be taken in the data analysis near (or below) the detection limit for the instrument; 5) no interferences or artifacts were found for the final results reported by the PC technique. -from Authors
引用
收藏
页码:3579 / 3597
页数:19
相关论文
共 25 条
  • [11] Kley D., 1980, ATMOS TECHNOL, V12, P63
  • [12] AUTOMATED FLUOROMETRIC METHOD FOR HYDROGEN-PEROXIDE IN ATMOSPHERIC PRECIPITATION
    LAZRUS, AL
    KOK, GL
    GITLIN, SN
    LIND, JA
    MCLAREN, SE
    [J]. ANALYTICAL CHEMISTRY, 1985, 57 (04) : 917 - 922
  • [13] AUTOMATED FLUOROMETRIC METHOD FOR HYDROGEN-PEROXIDE IN AIR
    LAZRUS, AL
    KOK, GL
    LIND, JA
    GITLIN, SN
    HEIKES, BG
    SHETTER, RE
    [J]. ANALYTICAL CHEMISTRY, 1986, 58 (03) : 594 - 597
  • [14] PARRISH DD, 1990, IN RPESS J GEOPHYS R
  • [15] HIGH SENSITIVITY POINT MONITORING OF ATMOSPHERIC GASES EMPLOYING TUNABLE DIODE-LASERS
    REID, J
    GARSIDE, BK
    SHEWCHUN, J
    ELSHERBINY, M
    BALLIK, EA
    [J]. APPLIED OPTICS, 1978, 17 (11): : 1806 - 1810
  • [16] HIGH SENSITIVITY POLLUTION DETECTION EMPLOYING TUNABLE DIODE-LASERS
    REID, J
    SHEWCHUN, J
    GARSIDE, BK
    BALLIK, EA
    [J]. APPLIED OPTICS, 1978, 17 (02): : 300 - 307
  • [17] NO AND NO2 IN THE TROPOSPHERE - TECHNIQUE AND MEASUREMENTS IN REGIONS OF A FOLDED TROPOPAUSE
    RIDLEY, BA
    CARROLL, MA
    GREGORY, GL
    SACHSE, GW
    [J]. JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 1988, 93 (D12): : 15813 - 15830
  • [18] INSTRUMENT FOR NITRIC-OXIDE MEASUREMENTS IN STRATOSPHERE
    RIDLEY, BA
    HOWLETT, LC
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1974, 45 (06) : 742 - 746
  • [19] ATMOSPHERIC MEASUREMENTS OF NITROGEN-DIOXIDE WITH A SENSITIVE LUMINOL INSTRUMENT
    SCHIFF, HI
    MACKAY, GI
    CASTLEDINE, C
    HARRIS, GW
    TRAN, Q
    [J]. WATER AIR AND SOIL POLLUTION, 1986, 30 (1-2) : 105 - 114
  • [20] SCHIFF HI, 1987, ACS SYM SER, V349, P274