SELECTIVE SYSTEM OF IDENTIFICATION AND DETERMINATION OF ANTIDEPRESSANTS AND NEUROLEPTICS IN SERUM OR PLASMA BY SOLID-PHASE EXTRACTION FOLLOWED BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH PHOTODIODE-ARRAY DETECTION IN ANALYTICAL TOXICOLOGY

被引:21
作者
BALIKOVA, M
机构
[1] Institute for Forensic Toxicology, Medical Faculty 1, Charles University, 121 08 Prague 2
来源
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS | 1992年 / 581卷 / 01期
关键词
D O I
10.1016/0378-4347(92)80449-Z
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A selective off-line solid-phase isolation of antidepressants, neuroleptics and other structurally related basic drugs from plasma or serum prior to high-performance liquid chromatography was tested and optimized for general use in toxicological analyses where concomitant drugs can be encountered. The sequential elution preseparated drug mixtures and simplified the subsequent analytical steps. High isolation efficiencies of cyano-bonded silica cartridges from Baker for fifteen amine drugs were determined. Isocratic chromatography on octadecylsilica proved to be very suitable for broad practical applications in complicated cases. The identification of an unknown peak was supported by photodiode-array detection in the range 200-400 nm with a resolution of 2 nm. The linearity of the assay from therapeutic to toxic concentrations was attained. Sufficient sensitivities covering low therapeutic levels of parent drugs and their demethylated metabolites were reached. The system is flexible and allows various methods of quantitative assay to be devised according to the conditions of a particular case in clinical or forensic toxicology.
引用
收藏
页码:75 / 81
页数:7
相关论文
共 30 条
[1]   DETERMINATION OF COMPOUND IDENTITY BY GROUP TYPE AND CLASS USING DIODE-ARRAY DETECTION IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
ALFREDSON, T ;
SHEEHAN, T ;
LENERT, T ;
AAMODT, S ;
CORREIA, L .
JOURNAL OF CHROMATOGRAPHY, 1987, 385 :213-223
[2]   STANDARDIZATION OF A MULTIWAVELENGTH UV DETECTOR FOR LIQUID CHROMATOGRAPHY-BASED TOXICOLOGICAL ANALYSIS [J].
BINDER, SR ;
ADAMS, AK ;
REGALIA, M ;
ESSIEN, H ;
ROSENBLUM, R .
JOURNAL OF CHROMATOGRAPHY, 1991, 550 (1-2) :449-459
[3]   STANDARDIZED HPLC/DAD SYSTEM, BASED ON RETENTION INDEXES AND SPECTRAL LIBRARY, APPLICABLE FOR SYSTEMATIC TOXICOLOGICAL SCREENING [J].
BOGUSZ, M ;
WU, M .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1991, 15 (04) :188-197
[4]  
BOUILEU R, 1990, J CHROMATOGR, V528, P542
[5]  
EDELBROEK PM, 1982, CLIN CHEM, V28, P2143
[6]   APPLICATION OF DIODE-ARRAY DETECTORS FOR SOLUTE IDENTIFICATION IN TOXICOLOGICAL ANALYSIS [J].
ENGELHARDT, H ;
KONIG, T .
CHROMATOGRAPHIA, 1989, 28 (7-8) :341-353
[7]   REVERSED-PHASE LIQUID-CHROMATOGRAPHY FOR THE SEPARATION OF CHLORPROMAZINE, IMIPRAMINE AND SOME OF THEIR METABOLITES [J].
FEKETE, J ;
DELCASTILHO, P ;
KRAAK, JC .
JOURNAL OF CHROMATOGRAPHY, 1981, 204 (JAN) :319-327
[8]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC SYSTEM FOR THE SEPARATION OF TRICYCLIC ANTIDEPRESSANT AND RELATED DRUGS USING ODS-HYPERSIL [J].
GILL, R ;
WANOGHO, SO .
JOURNAL OF CHROMATOGRAPHY, 1987, 391 (02) :461-464
[9]   COMPARISON OF METHODS FOR THE ANALYSIS OF TRICYCLIC ANTIDEPRESSANTS IN SMALL WHOLE-BLOOD SAMPLES [J].
HUGHES, RJ ;
OSSELTON, MD .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1989, 13 (02) :77-83
[10]   AUTOMATED IDENTIFICATION OF TOXIC-SUBSTANCES IN POISONED HUMAN FLUIDS BY A RETENTION PREDICTION SYSTEM IN REVERSED-PHASE LIQUID-CHROMATOGRAPHY [J].
JINNO, K ;
KUWAJIMA, M ;
HAYASHIDA, M ;
WATANABE, T ;
HONDO, T .
JOURNAL OF CHROMATOGRAPHY, 1988, 436 (01) :11-21