STANDARDIZATION OF A MULTIWAVELENGTH UV DETECTOR FOR LIQUID CHROMATOGRAPHY-BASED TOXICOLOGICAL ANALYSIS

被引:7
作者
BINDER, SR [1 ]
ADAMS, AK [1 ]
REGALIA, M [1 ]
ESSIEN, H [1 ]
ROSENBLUM, R [1 ]
机构
[1] BARSPEC SYST INC,IL-76103 REHOVOT,ISRAEL
来源
JOURNAL OF CHROMATOGRAPHY | 1991年 / 550卷 / 1-2期
关键词
PHOTODIODE ARRAY DETECTION; DIODE-ARRAY; SOLUTE IDENTIFICATION; ULTRAVIOLET-SPECTRA; PEAK RECOGNITION; LIBRARY SEARCH; SYSTEM; DRUGS; SPECTROMETER; SEPARATION;
D O I
10.1016/S0021-9673(01)88555-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The performance of a multi-wavelength UV detector for automated drug identification following liquid chromatographic separation was evaluated. The ability of selected wavelength ratios to distinguish two closely related drugs was considered at different concentrations. Calibration of the detector based on wavelength ratios was then utilized to standardize two different detectors and to evaluate instrument-to-instrument variation of a series of detectors. Reproducibility of the second-derivative zero intercept for these drug spectra was also evaluated. Standardization of detector performance by reference to these two parameters permitted the transfer of UV spectral libraries stored on one instrument to another without compromising the reliability of qualitative data.
引用
收藏
页码:449 / 459
页数:11
相关论文
共 38 条
[1]   DETERMINATION OF COMPOUND IDENTITY BY GROUP TYPE AND CLASS USING DIODE-ARRAY DETECTION IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
ALFREDSON, T ;
SHEEHAN, T ;
LENERT, T ;
AAMODT, S ;
CORREIA, L .
JOURNAL OF CHROMATOGRAPHY, 1987, 385 :213-223
[2]   IDENTIFICATION OF DRUGS BY HIGH-PRESSURE LIQUID-CHROMATOGRAPHY WITH DUAL WAVELENGTH ULTRAVIOLET DETECTION [J].
BAKER, JK ;
SKELTON, RE ;
MA, C .
JOURNAL OF CHROMATOGRAPHY, 1979, 168 (02) :417-427
[3]  
BASELT RC, 1987, ANAL PROCEDURES THER, P67
[4]   AUTOMATED LIQUID-CHROMATOGRAPHIC ANALYSIS OF DRUGS IN URINE BY ONLINE SAMPLE CLEANUP AND ISOCRATIC MULTICOLUMN SEPARATION [J].
BINDER, SR ;
REGALIA, M ;
BIAGGIMCEACHERN, M ;
MAZHAR, M .
JOURNAL OF CHROMATOGRAPHY, 1989, 473 (02) :325-341
[5]  
BOESSENKOOL HJ, 1986, MIKROCHIM ACTA, V2, P75
[6]  
BOGUSZ M, 1985, S BIOL HUNG, V34, P647
[7]   PHOTO-DIODE ARRAY DETECTORS FOR LC [J].
BORMAN, SA .
ANALYTICAL CHEMISTRY, 1983, 55 (08) :A836-&
[8]   AN EXPERT SYSTEM FOR ELUENT OPTIMIZATION IN LIQUID-CHROMATOGRAPHY WITH PHOTODIODE ARRAY DETECTION [J].
BRIDGE, TP ;
WILLIAMS, MH ;
SEATON, GGR ;
FELL, AF .
CHROMATOGRAPHIA, 1987, 24 :691-695
[9]   SEARCHING A UV-VISIBLE SPECTRAL LIBRARY [J].
BROWN, CW ;
DONAHUE, SM .
APPLIED SPECTROSCOPY, 1988, 42 (02) :347-352
[10]  
de Zeeuw R A, 1983, J Pharm Biomed Anal, V1, P435, DOI 10.1016/0731-7085(83)80057-0