STANDARDIZATION OF A MULTIWAVELENGTH UV DETECTOR FOR LIQUID CHROMATOGRAPHY-BASED TOXICOLOGICAL ANALYSIS

被引:7
作者
BINDER, SR [1 ]
ADAMS, AK [1 ]
REGALIA, M [1 ]
ESSIEN, H [1 ]
ROSENBLUM, R [1 ]
机构
[1] BARSPEC SYST INC,IL-76103 REHOVOT,ISRAEL
来源
JOURNAL OF CHROMATOGRAPHY | 1991年 / 550卷 / 1-2期
关键词
PHOTODIODE ARRAY DETECTION; DIODE-ARRAY; SOLUTE IDENTIFICATION; ULTRAVIOLET-SPECTRA; PEAK RECOGNITION; LIBRARY SEARCH; SYSTEM; DRUGS; SPECTROMETER; SEPARATION;
D O I
10.1016/S0021-9673(01)88555-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The performance of a multi-wavelength UV detector for automated drug identification following liquid chromatographic separation was evaluated. The ability of selected wavelength ratios to distinguish two closely related drugs was considered at different concentrations. Calibration of the detector based on wavelength ratios was then utilized to standardize two different detectors and to evaluate instrument-to-instrument variation of a series of detectors. Reproducibility of the second-derivative zero intercept for these drug spectra was also evaluated. Standardization of detector performance by reference to these two parameters permitted the transfer of UV spectral libraries stored on one instrument to another without compromising the reliability of qualitative data.
引用
收藏
页码:449 / 459
页数:11
相关论文
共 38 条
[21]   A PHOTO-DIODE ARRAY DETECTION SYSTEM - DESIGN CONCEPT AND IMPLEMENTATION [J].
GEORGE, SA ;
MAUTE, A .
CHROMATOGRAPHIA, 1982, 15 (07) :419-425
[22]   APPLICATION OF DERIVATIVE SPECTROSCOPY TO THE DETERMINATION OF CHROMATOGRAPHIC PEAK PURITY [J].
GRANT, A ;
BHATTACHARYYA, PK .
JOURNAL OF CHROMATOGRAPHY, 1985, 347 (02) :219-235
[23]   HPLC PHOTODIODE ARRAY UV DETECTION FOR TOXICOLOGICAL DRUG ANALYSIS [J].
HILL, DW ;
LANGNER, KJ .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1987, 10 (2-3) :377-409
[24]   COMPUTERIZED LIBRARY SEARCH ROUTINE FOR COMPARING ULTRAVIOLET-SPECTRA OF DRUGS SEPARATED BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
HILL, DW ;
KELLEY, TR ;
LANGNER, KJ .
ANALYTICAL CHEMISTRY, 1987, 59 (02) :350-353
[25]   MICROCOMPUTER-ASSISTED LIQUID-CHROMATOGRAPHIC SEPARATION SYSTEM - APPLICATION TO TOXIC COMPOUNDS IDENTIFICATION IN POISONED HUMAN FLUIDS [J].
JINNO, K ;
KUWAJIMA, M .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1989, 27 (02) :57-62
[26]  
KAFERSTEIN VH, 1986, BEITR GERICHTL MED, V44, P253
[27]  
MCDOWELL AE, 1976, CLIN CHEM, V22, P1862
[28]   RAPID SCANNING DIODE-ARRAY AS A MULTI-WAVELENGTH DETECTOR IN LIQUID-CHROMATOGRAPHY [J].
MILANO, MJ ;
LAM, S ;
GRUSHKA, E .
JOURNAL OF CHROMATOGRAPHY, 1976, 125 (01) :315-326
[29]   IDENTIFICATION OF DRUGS IN HUMAN-SERUM BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH PHOTODIODE ARRAY DETECTION AND A SEARCH ALGORITHM FOR ULTRAVIOLET-SPECTRA [J].
MINDER, EI ;
SCHAUBHUT, R ;
MINDER, CE ;
VONDERSCHMITT, DJ .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1987, 419 :135-154
[30]  
ROSS MSF, 1989, AM LAB JUN, P64