MENTOR ALPHA-1 INFLATABLE PENILE PROSTHESIS - PATIENT SATISFACTION AND DEVICE RELIABILITY

被引:27
作者
GARBER, BB
机构
[1] Division of Urology, The Graduate Hospital, Philadelphia, PA
关键词
D O I
10.1016/0090-4295(94)90047-7
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Objective. This report describes a study of patient satisfaction and device reliability in 50 organically impotent males who were implanted with a Mentor Alpha 1 inflatable penile prosthesis. Method. Data were obtained from review of medical records, and patient-completed structured questionnaires. Results. The average patient age was fifty-nine years (range: 25 to 90 years). Thirty-one patients (62%) had underlying medical conditions, and all tried at least one other treatment prior to implantation. All patients received perioperative prophylactic antibiotics, and all were drained with a closed suction drain for twenty-four hours. Follow-up ranged from two to forty-one months (av. 15 mos). Complications occurred in 2 patients (4%), including 1 periprosthetic infection and 1 intraoperative cylinder aneurysm. An average of one office visit was required for teaching inflation/deflation. Ninety-eight percent of the patients and 96 percent of their partners were satisfied with the device. Ninety-four percent and 96 percent thought the device was easy to inflate and deflate, respectively. Two patients (4%) reported partial cylinder inflation related to physical activity. All were satisfied with the girth and rigidity, but only 92 percent were satisfied with the length. Ninety-eight percent said they would undergo the procedure again and would recommend this implant to other impotent patients. Conclusions. These data indicate that the Mentor Alpha 1 device has good short-term mechanical reliability, and yields a high level of patient and partner satisfaction.
引用
收藏
页码:214 / 217
页数:4
相关论文
共 12 条
[1]  
CARSON CC, 1989, UROL CLIN N AM, V16, P139
[2]   MENTOR INFLATABLE PENILE PROSTHESIS [J].
ENGEL, RME ;
SMOLEV, JK ;
HACKLER, R .
UROLOGY, 1987, 29 (05) :498-500
[3]   INFECTIOUS COMPLICATIONS OF PENILE PROSTHESIS SURGERY [J].
KABALIN, JN ;
KESSLER, R .
JOURNAL OF UROLOGY, 1988, 139 (05) :953-955
[4]   PATIENT AND PARTNER SATISFACTION WITH THE AMS-700 PENILE PROSTHESIS [J].
MCLAREN, RH ;
BARRETT, DM .
JOURNAL OF UROLOGY, 1992, 147 (01) :62-65
[5]   CLINICAL-EXPERIENCE WITH THE MENTOR INFLATABLE PENILE PROSTHESIS IN 301 PATIENTS [J].
MERRILL, DC .
JOURNAL OF UROLOGY, 1988, 140 (06) :1424-1427
[6]  
MERRILL DC, 1989, UROL CLIN N AM, V16, P51
[7]   PERIPROSTHETIC INFECTIONS [J].
MONTAGUE, DK .
JOURNAL OF UROLOGY, 1987, 138 (01) :68-69
[8]   EVALUATION OF PATIENTS AND PARTNERS 1 TO 4 YEARS AFTER PENILE PROSTHESIS SURGERY [J].
PEDERSEN, B ;
TIEFER, L ;
RUIZ, M ;
MELMAN, A .
JOURNAL OF UROLOGY, 1988, 139 (05) :956-958
[9]   INTRALUMINAL DEVICE PRESSURES IN 3-PIECE INFLATABLE PENILE PROSTHESES - THE PATHOPHYSIOLOGY OF MECHANICAL MALFUNCTION [J].
PESCATORI, ES ;
GOLDSTEIN, I .
JOURNAL OF UROLOGY, 1993, 149 (02) :295-300
[10]   MECHANICAL COMPLICATIONS ASSOCIATED WITH MENTOR INFLATABLE PENILE PROSTHESIS [J].
STEINKOHL, WB ;
LEACH, GE .
UROLOGY, 1991, 38 (01) :32-34