RETRIEVAL OF TEMPERATURE-DEPTH PROFILES IN BIOLOGICAL OBJECTS FROM MULTIFREQUENCY MICROWAVE RADIOMETRIC DATA

被引:31
作者
MIZUSHINA, S
SHIMIZU, T
SUZUKI, K
KINOMURA, M
OHBA, H
SUGIURA, T
机构
[1] Research Institute of Electronics, Shizuoka University, Hamamatsu
关键词
D O I
10.1163/156939393X00642
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A method of retrieving a temperature-depth profile in biological object from a set of multi-frequency microwave radiometric data has been developed. The method is a combination of model-fitting and Monte Carlo techniques and is capable of estimating a profile and its confidence interval as a function of the depth. We use 2sigma-intervals as a measure of the precision of tissue temperature measurements. The method was tested and supported by an experiment in which temperature distributions in a muscle equivalent agar phantom were measured using a 5-band, 1-3.8 GHz radiometer with the brightness temperature resolution of 0.05-0.07 K. A typical result of the experiment showed that 2sigma-intervals were 1 K or less for 0 < z < 3 cm, 1.4 K at z = 4 cm, and 3 K at z = 5 cm. A numerical simulation study was made using this technique to assess effects of the selection of measurement frequencies, number of frequency bands, brightness temperature resolution of radiometer and thickness of fat layer on the precision. Results indicated that 2sigma-intervals of about 1.0 K or less over a 0-5 cm depth range could be achieved by a 6-band, 0.55-3.8 GHz radiometer with the brightness temperature resolution of 0.05 K.
引用
收藏
页码:1515 / 1548
页数:34
相关论文
共 36 条
[31]  
Guy A.W., Electromagnetic fields and relative heating pattern due to a rectangular aperture source in direct contact with bilayered biological tissues, IEEE Trans, on Microwave Theory Tech, MTT-19, pp. 214-223, (1971)
[32]  
Nikita K., Uzunoglu N., Analysis of power coupling from waveguide hyperthermia applicator into a three-layered tissue model, IEEE Trans, on Microwave Theory Tech, 37, pp. 1794-1801, (1989)
[33]  
Mamouni A., Leroy Y., Bocquet B., Van De Velde J.C., Gelin P.H., Computation of near-field microwave radiometric signals: Detection and experimental verification, IEEE Trans, on Microwave Theory Tech, 39, pp. 124-132, (1991)
[34]  
Bocquet B., Dehour P., Mamouni A., Van De Velde J.C., Leroy Y., Near field microwave radiometric weighting functions for multilayered materials, J. Electromagnetic Waves and Applicat
[35]  
Hand J.W., Lagendijk J.J., Andersen J.B., Bolomey J.C., Quality assurance guidelines for ESHO protocols, Int. Journal of Hyperthermia, 5, pp. 421-428, (1989)
[36]  