A LOW-FLOW TO-AND-FRO SYSTEM - LABORATORY STUDY OF MIXING OF ANESTHETIC AND DRIVING GASES DURING MECHANICAL VENTILATION

被引:7
作者
KADIM, MY
LOCKWOOD, GG
CHAKRABARTI, MK
WHITWAM, JG
机构
[1] Department of Anaesthetics, Hammersmith Hospital, London, W12, DuCane Road
关键词
EQUIPMENT; BREATHING SYSTEMS; ABSORBERS;
D O I
10.1111/j.1365-2044.1991.tb09856.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The insertion of a long deadspace tube between an anaesthetic breathing system and a ventilator produces only imperfect separation of the breathing system gas from the driving gas. This laboratory study has investigated different connecting tubes to establish the maximum tidal volume possible before ventilator gas contaminates the gas in a low‐flow to‐and‐fro system (fresh gas flow 1 litre/minute). A larger volume tube enables the use of larger tidal volumes, and plastic corrugated tubes are slightly better than black rubber corrugated tubes in this respect. The maximum tidal volume possible without contamination decreases as ventilatory rate increases, but the maximum minute volume is increased. A 22 mm plastic corrugated tube of internal volume 1.5 litres should be adequate for clinical use with the to‐and‐fro system described in this study at afresh gas flow of 1 litre/minute. Copyright © 1991, Wiley Blackwell. All rights reserved
引用
收藏
页码:948 / 951
页数:4
相关论文
共 9 条
[1]   BAIN CIRCUIT - PREVENTION OF ANESTHETIC MIXTURE DILUTION WHEN USING MECHANICAL VENTILATORS DELIVERING NON-ANESTHETIC GASES [J].
ADAMS, AP .
ANAESTHESIA, 1977, 32 (01) :46-49
[2]   A NEW VALVELESS ALL-PURPOSE VENTILATOR - DESCRIPTION AND LABORATORY EVALUATION [J].
CHAKRABARTI, MK ;
WHITWAM, JG .
BRITISH JOURNAL OF ANAESTHESIA, 1983, 55 (10) :1005-1015
[3]   RELATIONSHIP BETWEEN FREQUENCY OF VENTILATION, AIRWAYS AND PULMONARY-ARTERY PRESSURES, CARDIAC-OUTPUT AND TRACHEAL TUBE DEADSPACE [J].
CHAKRABARTI, MK ;
GROUNDS, RM ;
SWENZEN, GO ;
WHITWAM, JG .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1986, 30 (08) :678-684
[4]   A LOW FLOW OPEN CIRCLE SYSTEM FOR ANESTHESIA .1. LABORATORY EVALUATION AT NORMAL AND HIGH-FREQUENCIES [J].
CHAKRABARTI, MK ;
STACEY, RGW ;
HOLDCROFT, A ;
WHITWAM, JG .
ANAESTHESIA, 1990, 45 (04) :314-317
[5]   METHOD OF CONTROLLED VENTILATION WITH A CIRCLE-ABSORBER BREATHING SYSTEM [J].
JEAL, DE .
BRITISH JOURNAL OF ANAESTHESIA, 1977, 49 (03) :273-276
[6]  
MCPEAK H, 1988, ANAESTHESIA, V43, P1035
[7]   VENTILATION STANDARDS FOR USE IN ARTIFICIAL RESPIRATION [J].
RADFORD, EP .
JOURNAL OF APPLIED PHYSIOLOGY, 1955, 7 (04) :451-460
[8]   CONTROLLED VENTILATION WITH MAPLESON-D SYSTEM - THEORETICAL AND EXPERIMENTAL-STUDY [J].
SEELEY, HF ;
BARNES, PK ;
CONWAY, CM .
BRITISH JOURNAL OF ANAESTHESIA, 1977, 49 (02) :107-114
[9]  
Voss T J, 1967, S Afr Med J, V41, P1079