HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH AMPEROMETRIC DETECTION APPLIED TO THE SCREENING OF BETA-BLOCKERS IN HUMAN URINE

被引:30
作者
MAGUREGUI, MI [1 ]
ALONSO, RM [1 ]
JIMENEZ, RM [1 ]
机构
[1] UNIV BASQUE COUNTRY, FAC CIENCIAS, DEPT QUIM ANALIT, E-48080 BILBAO, SPAIN
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 1995年 / 674卷 / 01期
关键词
D O I
10.1016/0378-4347(95)00303-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A high-performance liquid chromatographic method with electrochemical detection has been developed for the determination of six beta-blockers: atenolol, nadolol, timolol, metoprolol, oxprenolol, and alprenolol. The chromatographic separation was performed using a mu Bondapack C-18 column, a mobile phase of acetonitrile-water (40:60), containing 5 mM KH2PO4/K2HPO4 proved to be optimal at a 1.3 ml/min flow-rate, and a pH of 6.5. The temperature was optimized at 30 +/- 0.2 degrees C. The amperometric detector, equipped with a glassy carbon electrode, was operated at 1300 mV versus Ag/AgCl in the direct current mode. The method was applied to the determination of these compounds at two concentration levels: ppm and ppb (ng/ml), obtaining relative standard deviations lower than 5% at ppm levels and lower than 10% at ppb levels, and quantitation limits ranging from 15 ppb to 500 ppb. The method was applied to the screening of beta-blockers in spiked urine samples, with a total elution time lower than 12 min, obtaining the best recoveries for timolol and metoprolol (never greater than 93%). These recoveries together with the low limits of quantitation achieved, allows its application to doping analysis in human urine.
引用
收藏
页码:85 / 91
页数:7
相关论文
共 24 条
[1]   LABETALOL ANALYSIS IN HUMAN-PLASMA USING LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION - APPLICATION TO PHARMACOKINETIC STUDIES [J].
ABERNETHY, DR ;
TODD, EL ;
EGAN, JL ;
CARRUM, G .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1986, 9 (10) :2153-2164
[2]  
BETNALL AE, 1993, ANAL P, V30, P367
[3]   INTERFERENCE OF LABETALOL METABOLITES IN THE DETERMINATION OF PLASMA-CATECHOLAMINES BY HPLC WITH ELECTROCHEMICAL DETECTION [J].
BOULOUX, PMG ;
PERRETT, D .
CLINICA CHIMICA ACTA, 1985, 150 (02) :111-117
[4]  
DEJONG EG, 1988, TRENDS ANAL CHEM, V7, P376
[5]  
GLUTH WP, 1991, PHARMAZIE, V46
[6]  
GREEGG MR, 1984, J CHROMATOGR, V305, P244
[7]   THE EFFECT OF PREANODIZATION ON THE ELECTROCHEMICAL DETECTION OF OPRENOLOL IN PLASMA [J].
GREGG, MR .
CHROMATOGRAPHIA, 1986, 21 (12) :705-707
[8]   SIMPLE AND RAPID ANALYSIS OF ATENOLOL AND METOPROLOL IN PLASMA USING SOLID-PHASE EXTRACTION AND HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
HARRISON, PM ;
TONKIN, AM ;
MCLEAN, AJ .
JOURNAL OF CHROMATOGRAPHY, 1985, 339 (02) :429-433
[9]   DETERMINATION OF LOW PLASMA TIMOLOL CONCENTRATIONS FOLLOWING TOPICAL APPLICATION OF TIMOLOL EYE DROPS IN HUMANS BY HIGHPERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION [J].
HE, HB ;
EDEKI, TI ;
WOOD, AJJ .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1994, 661 (02) :351-356
[10]   SIMULTANEOUS MICROQUANTIFICATION OF NIFEDIPINE AND ATENOLOL IN MULTICOMPONENT DOSAGE FORMS USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
JAIN, R ;
JAIN, CL .
MICROCHEMICAL JOURNAL, 1991, 44 (02) :187-192