DIAGNOSING BREAST IMPLANT RUPTURE WITH MR-IMAGING, US, AND MAMMOGRAPHY

被引:61
作者
BERG, WA
CASKEY, CI
HAMPER, UM
ANDERSON, ND
CHANG, BW
SHETH, S
ZERHOUNI, EA
KUHLMAN, JE
机构
[1] JOHNS HOPKINS MED INST,RADIOL SERV,BALTIMORE,MD 21287
[2] JOHNS HOPKINS MED INST,DEPT INTERNAL MED,BALTIMORE,MD 21287
[3] JOHNS HOPKINS MED INST,DEPT PLAST & RECONSTRUCT SURG,BALTIMORE,MD 21287
关键词
BREAST; MR; PROSTHESES; US;
D O I
10.1148/radiographics.13.6.8290727
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A total of 135 symptomatic women with 262 breast implants were examined with magnetic resonance (MR) imaging performed with a body coil, ultrasound (US), or both to determine imaging features of implant rupture. Surgical proof was available for 33 women with 62 implants; 24 were ruptured and 38 were intact. Complicated internal structure was the most reliable predictor of implant rupture: Diffuse low-level echoes were seen on sonograms in 56% of ruptured implants; internal membranes (which correspond to the collapsed implant shell) were seen on MR images in 58% of ruptured implants. Fluid droplets were seen within the silicone in 26% of ruptured implants on MR images. Irregular implant contour can be a sign of rupture but is unreliable. Fluid collections around silicone implants are not a sign of rupture. At present, neither US nor conventional MR imaging with a body coil is sufficiently reliable to advocate routine screening of asymptomatic women with breast implants. Evaluation with MR imaging performed with a surface coil is more reliable.
引用
收藏
页码:1323 / 1336
页数:14
相关论文
共 17 条
  • [11] SILICONE BREAST IMPLANTS INVIVO - MR IMAGING
    GORCZYCA, DP
    SINHA, S
    AHN, CY
    DEBRUHL, ND
    HAYES, MK
    GAUSCHE, VR
    SHAW, WW
    BASSETT, LW
    [J]. RADIOLOGY, 1992, 185 (02) : 407 - 410
  • [12] SILICONE IMPLANT RUPTURE - DETECTION WITH US
    HARRIS, KM
    GANOTT, MA
    SHESTAK, KC
    LOSKEN, HW
    TOBON, H
    [J]. RADIOLOGY, 1993, 187 (03) : 761 - 768
  • [13] SILICONE GRANULOMAS - DETECTION BY ULTRASONOGRAPHY
    HERZOG, P
    [J]. PLASTIC AND RECONSTRUCTIVE SURGERY, 1989, 84 (05) : 856 - 857
  • [14] HUANG TT, 1978, PLAST RECONSTR SURG, V60, P277
  • [15] RUPTURED GEL-FILLED SILICONE BREAST IMPLANTS - SONOGRAPHIC FINDINGS IN 19 CASES
    ROSCULET, KA
    IKEDA, DM
    FORREST, ME
    ONEAL, RM
    RUBIN, JM
    JEFFRIES, DO
    HELVIE, MA
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1992, 159 (04) : 711 - 716
  • [16] FALSE-POSITIVE RADIOGRAPHIC DIAGNOSIS OF BREAST IMPLANT RUPTURE - REPORT OF 2 CASES
    SMITH, DS
    [J]. ANNALS OF PLASTIC SURGERY, 1985, 14 (02) : 166 - 167
  • [17] BREAST IMPLANTS, COMMON COMPLICATIONS, AND CONCURRENT BREAST DISEASE
    STEINBACH, BG
    HARDT, NS
    ABBITT, PL
    LANIER, L
    CAFFEE, HH
    [J]. RADIOGRAPHICS, 1993, 13 (01) : 95 - 118