Use of Continuous Glucose Monitoring in Patients with Type 1 Diabetes

被引:9
作者
Ellis, Samuel L. [1 ]
Naik, Ramachandra G. [1 ]
Gemperline, Kate [1 ]
Garg, Satish K. [1 ]
机构
[1] Univ Colorado Denver, Barbara Davis Ctr Diabet, A140,POB 6511, Aurora, CO 80045 USA
关键词
HbA1c; Continuous glucose monitoring; Type 1 diabetes mellitus; Hypoglycemia; Glucose variability;
D O I
10.2174/157339908785294370
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The prevalence of type 1 diabetes continues to increase worldwide at a rate higher than previously projected, while the number of patients achieving American Diabetes Association (ADA) glycated hemoglobin (A1c) goals remains suboptimal. There are numerous barriers to patients achieving A1c targets including increased frequency of severe hypoglycemia associated with lowering plasma glucose as measured by lower A1c values. Continuous glucose monitoring (CGM) was first approved for retrospective analysis and now has advanced to the next step in diabetes management with the approval of real- time glucose sensing. Real- time CGM, in short term studies, has been shown to decrease A1c values, improve glucose variability (GV), and minimize the time and number of hypoglycemic events in patients with type 1 diabetes. These products are approved for adjunctive use to self- monitoring of blood glucose (SMBG), but future long- term studies are needed to document their safety, efficacy, ability to replace SMBG as a tool of monitoring, and ultimately utility into closed- loop insulin delivery systems. New algorithms will need to be developed that account for rapid changes in the glucose values, so that accuracy of the sensor data can be maintained. In addition, for better clinical care and usage, algorithms also need to be developed for both patients and the providers to guide them for their ongoing diabetes care.
引用
收藏
页码:207 / 217
页数:11
相关论文
共 43 条
[31]   Comparison of metabolic control in a cross-sectional study of 2,873 children and adolescents with IDDM from 18 countries [J].
Mortensen, HB ;
Hougaard, P .
DIABETES CARE, 1997, 20 (05) :714-720
[32]   Worldwide increase in incidence of Type I diabetes -: the analysis of the data on published incidence trends [J].
Onkamo, P ;
Väänänen, S ;
Karvonen, M ;
Tuomilehto, J .
DIABETOLOGIA, 1999, 42 (12) :1395-1403
[33]   Factors associated with glycemic control -: A cross-sectional nationwide study in 2,579 French children with type 1 diabetes [J].
Rosilio, M ;
Cotton, JB ;
Wieliczko, MC ;
Gendrault, B ;
Carel, JC ;
Couvaras, O ;
Ser, N ;
Gillet, P ;
Soskin, S ;
Garandeau, P ;
Stuckens, C ;
Le Luyer, B ;
Jos, J ;
Bony-Trifunovic, H ;
Bertrand, AM ;
Leturcq, F ;
Lafuma, A ;
Bougnères, PF .
DIABETES CARE, 1998, 21 (07) :1146-1153
[34]   Poor control of risk factors for vascular disease among adults with previously diagnosed diabetes [J].
Saydah, SH ;
Fradkin, J ;
Cowie, CC .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2004, 291 (03) :335-342
[35]   The Continuous Glucose Monitoring System (CGMS) in type 1 diabetic children is the way to reduce hypoglycemic risk [J].
Schiaffini, R ;
Ciampalini, P ;
Fierabracci, A ;
Spera, S ;
Borrelli, P ;
Bottazzo, GF ;
Crinò, A .
DIABETES-METABOLISM RESEARCH AND REVIEWS, 2002, 18 (04) :324-329
[36]   THE EFFECT OF INTENSIVE TREATMENT OF DIABETES ON THE DEVELOPMENT AND PROGRESSION OF LONG-TERM COMPLICATIONS IN INSULIN-DEPENDENT DIABETES-MELLITUS [J].
SHAMOON, H ;
DUFFY, H ;
FLEISCHER, N ;
ENGEL, S ;
SAENGER, P ;
STRELZYN, M ;
LITWAK, M ;
WYLIEROSETT, J ;
FARKASH, A ;
GEIGER, D ;
ENGEL, H ;
FLEISCHMAN, J ;
POMPI, D ;
GINSBERG, N ;
GLOVER, M ;
BRISMAN, M ;
WALKER, E ;
THOMASHUNIS, A ;
GONZALEZ, J ;
GENUTH, S ;
BROWN, E ;
DAHMS, W ;
PUGSLEY, P ;
MAYER, L ;
KERR, D ;
LANDAU, B ;
SINGERMAN, L ;
RICE, T ;
NOVAK, M ;
SMITHBREWER, S ;
MCCONNELL, J ;
DROTAR, D ;
WOODS, D ;
KATIRGI, B ;
LITVENE, M ;
BROWN, C ;
LUSK, M ;
CAMPBELL, R ;
LACKAYE, M ;
RICHARDSON, M ;
LEVY, B ;
CHANG, S ;
HEINHEINEMANN, M ;
BARRON, S ;
ASTOR, L ;
LEBECK, D ;
BRILLON, D ;
DIAMOND, B ;
VASILASDWOSKIN, A ;
LAURENZI, B .
NEW ENGLAND JOURNAL OF MEDICINE, 1993, 329 (14) :977-986
[37]  
STONE RA, 1990, DIABETES, V39, P858
[38]  
Tamborlane W, 2008, DIABETES TECHNOL THE
[39]   Use of the continuous glucose monitoring system to guide therapy in patients with insulin-treated diabetes: A randomized controlled trial [J].
Tanenberg, R ;
Bode, B ;
Lane, W ;
Levetan, C ;
Mestman, J ;
Harmel, AP ;
Tobian, J ;
Gross, T ;
Mastrototaro, J .
MAYO CLINIC PROCEEDINGS, 2004, 79 (12) :1521-1526
[40]  
Vehik K, 2006, DIABETES, V55, pA56