FLUOROMETRIC FLOW-THROUGH SENSOR FOR ALUMINUM SPECIATION

被引:20
作者
CANIZARES, P [1 ]
DECASTRO, MDL [1 ]
机构
[1] UNIV CORDOBA,FAC SCI,DEPT ANALYT CHEM,E-14004 CORDOBA,SPAIN
关键词
FLUOROMETRY; SENSORS; FLOW SYSTEM; FLOW-THROUGH SENSOR; ALUMINUM; SPECIATION; COMPLEX FORMATION; DRISCOLL METHOD;
D O I
10.1016/0003-2670(94)80334-X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A fluorimetric flow-through integrated sensor for aluminium based on C-18 packed in a flow-cell located in a conventional spectrofluorimeter is reported. The sensor is suitable for aluminium speciation thanks to the aid of an appropriate flow-injection manifold where a modification of the Driscoll methodology based on the use of a fluorimetric reagent is accomplished in an automatic way. Three forms of aluminium (i.e., acid reactive aluminium, total monomeric aluminium, and non-labile monomeric aluminium) can be determined and two other forms (i.e., acid soluble and labile monomeric) can be calculated as the difference by injecting three sample aliquots into the continuous system and making use of an in-line ion-exchange microcolumn. The overall system is applied to aluminium speciation in different types of water.
引用
收藏
页码:59 / 65
页数:7
相关论文
共 19 条
[1]   FLOW-INJECTION AND LIQUID-CHROMATOGRAPHIC DETERMINATION OF ALUMINUM BASED ON ITS FLUORIMETRIC REACTION WITH 8-HYDROXYQUINOLINE-5-SULFONIC ACID IN A MICELLAR MEDIUM [J].
ALONSO, JIG ;
GARCIA, AL ;
SANZMEDEL, A ;
GONZALEZ, EB ;
EBDON, L ;
JONES, P .
ANALYTICA CHIMICA ACTA, 1989, 225 (02) :339-350
[2]   SPECIATION OF ALUMINUM IN AQUEOUS-SOLUTIONS USING ION CHROMATOGRAPHY [J].
BERTSCH, PM ;
ANDERSON, MA .
ANALYTICAL CHEMISTRY, 1989, 61 (06) :535-539
[3]   SPECIATION OF ALUMINUM IN ACIDIC FRESH-WATERS [J].
CAMPBELL, PGC ;
BISSON, M ;
BOUGIE, R ;
TESSIER, A ;
VILLENEUVE, JP .
ANALYTICAL CHEMISTRY, 1983, 55 (14) :2246-2252
[4]  
CANIZARES P, 1993, ANAL LETT, V27, P247
[5]   FLOW-THROUGH SENSING DEVICE BASED ON DERIVATIVE SYNCHRONOUS FLUORESCENCE MEASUREMENTS FOR THE MULTI-DETERMINATION OF B-6 VITAMERS [J].
CHEN, DH ;
DECASTRO, MDL ;
VALCARCEL, M .
ANALYTICA CHIMICA ACTA, 1992, 261 (1-2) :269-274
[6]  
DECASTRO MDL, 1986, TRAC-TREND ANAL CHEM, V5, P71
[7]  
DECASTRO MDL, 1994, QUALITY ASSURANCE EN
[8]   EFFECT OF ALUMINUM SPECIATION ON FISH IN DILUTE ACIDIFIED WATERS [J].
DRISCOLL, CT ;
BAKER, JP ;
BISOGNI, JJ ;
SCHOFIELD, CL .
NATURE, 1980, 284 (5752) :161-164
[9]   IMPROVED DETERMINATION OF ALUMINUM SPECIES IN WATERS USING FIA SEPARATION FLUOROMETRIC DETECTION TECHNIQUES [J].
FAIRMAN, B ;
SANZMEDEL, A .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1993, 50 (03) :161-171
[10]   FLOW-THROUGH SENSOR FOR THE DIRECT DETERMINATION OF PESTICIDE MIXTURES WITHOUT CHROMATOGRAPHIC-SEPARATION [J].
FERNANDEZBAND, B ;
LINARES, P ;
DECASTRO, MDL ;
VALCARCEL, M .
ANALYTICAL CHEMISTRY, 1991, 63 (17) :1672-1675