PARALLEL MONITORING FOR MULTIPLE TARGETED COMPOUNDS BY ION-TRAP MASS-SPECTROMETRY

被引:28
作者
ASANO, KG [1 ]
GOERINGER, DE [1 ]
MCLUCKEY, SA [1 ]
机构
[1] OAK RIDGE NATL LAB,DIV CHEM & ANALYT SCI,OAK RIDGE,TN 37831
关键词
D O I
10.1021/ac00113a003
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An approach to monitoring for the presence of several targeted compounds simultaneously using ion trap mass spectrometry is described. The use of tailored waveforms sequentially applied to the ion trap end-cap electrodes allows for mass-selective accumulation of multiple parent ions and simultaneous collisional activation of the ions. Further mass selection and ion activation steps can be performed to enhance specificity, The detection of trace explosives in air is used as an illustrative case in which 2,4-dinitrotoluene, 2,4,6-trinitrotoluene, and (2,4,6-trinitrophenyl)methylnitramine are targeted for detection. The parallel monitoring scheme trades specificity for advantages in speed and duty cycle relative to tandem mass spectrometry experiments performed in series.
引用
收藏
页码:2739 / 2742
页数:4
相关论文
共 19 条
[1]  
Busch KL., 1988, MASS SPECTROMETRY MA
[2]   STORED WAVE-FORM SIMULTANEOUS MASS-SELECTIVE EJECTION EXCITATION FOR FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY [J].
CHEN, L ;
MARSHALL, AG .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1987, 79 (01) :115-125
[3]  
Dionne B. C., 1986, J ENERG MATER, V4, P447
[4]   FILTERED NOISE FIELD SIGNALS FOR MASS-SELECTIVE ACCUMULATION OF EXTERNALLY FORMED IONS IN A QUADRUPOLE ION-TRAP [J].
GOERINGER, DE ;
ASANO, KG ;
MCLUCKEY, SA ;
HOEKMAN, D ;
STILLER, SW .
ANALYTICAL CHEMISTRY, 1994, 66 (03) :313-318
[5]   STORED WAVE-FORM INVERSE FOURIER-TRANSFORM AXIAL EXCITATION/EJECTION FOR QUADRUPOLE ION-TRAP MASS-SPECTROMETRY [J].
GUAN, SH ;
MARSHALL, AG .
ANALYTICAL CHEMISTRY, 1993, 65 (09) :1288-1294
[6]   TANDEM-IN-SPACE AND TANDEM-IN-TIME MASS-SPECTROMETRY - TRIPLE QUADRUPOLES AND QUADRUPOLE ION TRAPS [J].
JOHNSON, JV ;
YOST, RA ;
KELLEY, PE ;
BRADFORD, DC .
ANALYTICAL CHEMISTRY, 1990, 62 (20) :2162-2172
[7]   BROAD-BAND EXCITATION IN THE QUADRUPOLE ION-TRAP MASS-SPECTROMETER USING SHAPED PULSES CREATED WITH THE INVERSE FOURIER-TRANSFORM [J].
JULIAN, RK ;
COOKS, RG .
ANALYTICAL CHEMISTRY, 1993, 65 (14) :1827-1833
[8]  
Kelley P. E, 1992, U.S. Patent, Patent No. [5,134,286, 5134286]
[9]   SIMULTANEOUS ISOLATION OF 2 DIFFERENT M/Z IONS IN AN ION-TRAP MASS-SPECTROMETER AND THEIR TANDEM MASS-SPECTRA USING FILTERED-NOISE FIELDS [J].
KENNY, DV ;
CALLAHAN, PJ ;
GORDON, SM ;
STILLER, SW .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1993, 7 (12) :1086-1089
[10]   DIRECT ANALYSIS OF MIXTURES BY MASS-SPECTROMETRY [J].
KONDRAT, RW ;
COOKS, RG .
ANALYTICAL CHEMISTRY, 1978, 50 (01) :A81-&