AN IMPROVED MICRO ENZYME SENSOR FOR BIOPROCESS MONITORING BY FLOW-INJECTION ANALYSIS

被引:4
作者
HAEMMERLI, S
SCHAEFFLER, A
MANZ, A
WIDMER, HM
机构
[1] Analytical Research FO 3.2, Ciba-Geigy Ltd.
关键词
D O I
10.1016/0925-4005(92)80333-S
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An improved micro enzyme electrode is presented for on-line determination of glucose during bioprocesses. The disposable sensor was constructed on the basis of an integrated microelectrode (from the Institute of Microtechnique, University of Neuchatel) and used as detector in a flow injection analysis (FIA) system. Glucose oxidase was incorporated in a polyvinyl pyridine matrix doped with mediator molecules and deposited on the electrode. The performance of this sensor was tested during the cultivation of yeast. The obtained results were compared with the data from a different flow injection method. using enzyme columns and colorimetric detection.
引用
收藏
页码:404 / 407
页数:4
相关论文
共 9 条
[1]   THE COMBINATION OF AN AMPEROMETRIC INTEGRATED GLUCOSE SENSOR WITH FLOW-INJECTION ANALYSIS FOR BIOPROCESS CONTROL [J].
BATAILLARD, P ;
HAEMMERLI, S ;
LUDI, H ;
WIDMER, HM .
SENSORS AND ACTUATORS B-CHEMICAL, 1991, 4 (3-4) :309-313
[2]   FERROCENE-MEDIATED ENZYME ELECTRODE FOR AMPEROMETRIC DETERMINATION OF GLUCOSE [J].
CASS, AEG ;
DAVIS, G ;
FRANCIS, GD ;
HILL, HAO ;
ASTON, WJ ;
HIGGINS, IJ ;
PLOTKIN, EV ;
SCOTT, LDL ;
TURNER, APF .
ANALYTICAL CHEMISTRY, 1984, 56 (04) :667-671
[3]   ELECTROPOLYMERIZATION OF VINYLPYRIDINE AND VINYLBIPYRIDINE COMPLEXES OF IRON AND RUTHENIUM - HOMOPOLYMERS, COPOLYMERS, REACTIVE POLYMERS [J].
DENISEVICH, P ;
ABRUNA, HD ;
LEIDNER, CR ;
MEYER, TJ ;
MURRAY, RW .
INORGANIC CHEMISTRY, 1982, 21 (06) :2153-2161
[4]   ONLINE DETERMINATION OF GLUCOSE IN BIOTECHNOLOGICAL PROCESSES - COMPARISON BETWEEN FIA AND AN INSITU ENZYME ELECTRODE [J].
FILIPPINI, C ;
SONNLEITNER, B ;
FIECHTER, A ;
BRADLEY, J ;
SCHMID, R .
JOURNAL OF BIOTECHNOLOGY, 1991, 18 (1-2) :153-160
[5]   A FLOW-INJECTION ANALYSIS SYSTEM FOR FERMENTATION MONITORING AND CONTROL [J].
GARN, M ;
GISIN, M ;
THOMMEN, C ;
CEVEY, P .
BIOTECHNOLOGY AND BIOENGINEERING, 1989, 34 (04) :423-428
[6]   ENZYME ELECTRODE FOR AMPEROMETRIC DETERMINATION OF GLUCOSE [J].
GUILBAULT, GG ;
LUBRANO, GJ .
ANALYTICA CHIMICA ACTA, 1973, 64 (03) :439-455
[7]  
KOUDELKA M, 1989, SENSOR ACTUATOR, V18, P59
[8]   BIOCHEMICAL SENSORS IN INDUSTRY [J].
LUDI, H ;
BATAILLARD, P ;
HAEMMERLI, S ;
WIDMER, HM .
SENSORS AND ACTUATORS B-CHEMICAL, 1991, 4 (1-2) :207-209
[9]   LEACHING OF DIMETHYLFERROCENE, A REDOX MEDIATOR IN AMPEROMETRIC ENZYME ELECTRODES [J].
SCHUHMANN, W ;
WOHLSCHLAGER, H ;
LAMMERT, R ;
SCHMIDT, HL ;
LOFFLER, U ;
WIEMHOFER, HD ;
GOPEL, W .
SENSORS AND ACTUATORS B-CHEMICAL, 1990, 1 (1-6) :571-575