DETECTION LIMITS VERSUS MATRIX EFFECTS - ANALYSIS OF SOLUTIONS WITH HIGH AMOUNTS OF DISSOLVED SOLIDS BY FLOW-INJECTION INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY

被引:23
作者
RICHNER, P
机构
[1] Swiss Federal Laboratories for Materials Testing and Research
关键词
INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY; FLOW INJECTION; MATRIX EFFECTS; NICKEL ANALYSIS;
D O I
10.1039/ja9930800927
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Flow injection inductively coupled plasma mass spectrometry (FI-ICP-MS) has been used for the analysis of high-purity nickel (>99.99% m/m). The advantage of analysing solutions with high amounts of dissolved solids (i.e., 3% m/m Ni) offered by FI-ICP-MS compared with conventional solution nebulization with 0.05% Ni solutions results in detection limits in the ng of analyte per g of Ni range because of the small dilution factor. Stable operating conditions can be maintained with the injection of 200 mul sample volumes in a carrier stream of 1% HNO3 with a relative standard deviation of less than 2% and 5% drift on 13 consecutive injections in 15 min. For certain elements severe matrix effects caused by the high Ni concentrations were found when the signal depression was compared with 1% HNO3 solutions, it varied between less than 5% for Rb and 80% for B. This depression is a function of the degree of ionization of the analyte element: the smaller the degree of ionization the higher the matrix effect. For quantitative analysis an automated standard additions procedure was applied because it was impossible to compensate for the different matrix effects by internal standards.
引用
收藏
页码:927 / 931
页数:5
相关论文
共 13 条
[1]  
Boumans P.W.J.M., 1987, INDUCTIVELY COUPLE 2
[2]  
BOUMANS PWJ, 1966, THEORY SPECTROCHEMIC, P156
[3]   ONLINE PRECONCENTRATION AND DETERMINATION OF TRACE-ELEMENTS BY FLOW-INJECTION INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY [J].
CAROLI, S ;
ALIMONTI, A ;
PETRUCCI, F ;
HORVATH, Z .
ANALYTICA CHIMICA ACTA, 1991, 248 (01) :241-249
[4]   ELECTRONIC PARTITION FUNCTIONS OF ATOMS AND IONS BETWEEN 1500 DEGREES K AND 7000 DEGREES K [J].
DEGALAN, L ;
SMITH, R ;
WINEFORDNER, JD .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1968, B 23 (08) :521-+
[5]   ANALYSIS OF SOLUTIONS CONTAINING HIGH-LEVELS OF DISSOLVED SOLIDS BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
HUTTON, RC ;
EATON, AN .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1988, 3 (04) :547-550
[6]  
Jarvis K. E., 1992, HDB INDUCTIVELY COUP
[7]   SAMPLE ANALYSIS BY ONLINE ISOTOPE-DILUTION INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
LASZTITY, A ;
VICZIAN, M ;
WANG, XR ;
BARNES, RM .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1989, 4 (08) :761-766
[9]   FLOW-INJECTION TECHNIQUE FOR DETERMINATION OF THALLIUM, LEAD AND BISMUTH IN NICKEL-BASE ALLOYS BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
MOCHIZUKI, T ;
SAKASHITA, A ;
IWATA, H ;
ISHIBASHI, Y ;
GUNJI, N .
ANALYTICAL SCIENCES, 1990, 6 (02) :191-194
[10]   DETERMINATION OF GERMANIUM, PALLADIUM AND PLATINUM IN HIGHLY CONCENTRATED-SOLUTIONS OF PHOSPHORIC-ACID AND AMMONIUM-NITRATE BY FLOW-INJECTION INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY (FI-ICP-MS) [J].
PENG, ZC ;
KLINKENBERG, H ;
BEEREN, T ;
VANBORM, W .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1991, 46 (6-7) :1051-1061