REST AND TREADMILL EXERCISE FIRST-PASS RADIONUCLIDE VENTRICULOGRAPHY - VALIDATION OF LEFT-VENTRICULAR EJECTION FRACTION MEASUREMENTS

被引:29
作者
FRIEDMAN, JD
BERMAN, DS
KIAT, H
BIETENDORF, J
HYUN, M
VANTRAIN, KF
WANG, FP
机构
[1] CEDARS SINAI MED CTR,DEPT IMAGING,DIV NUCL MED,LOS ANGELES,CA 90048
[2] CEDARS SINAI MED CTR,DEPT MED,DIV CARDIOL,LOS ANGELES,CA 90048
[3] UNIV CALIF LOS ANGELES,SCH MED,DEPT MED,LOS ANGELES,CA
关键词
TECHNETIUM 99M-LABELED SESTAMIBI; FIRST-PASS RADIONUCLIDE VENTRICULOGRAPHY; MYOCARDIAL FUNCTION; MYOCARDIAL PERFUSION; LEFT VENTRICULAR EJECTION FRACTION;
D O I
10.1007/BF02939959
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. To assess the accuracy of rest and treadmill exercise first-pass radionuclide ventriculographic measurements of left ventricular ejection fraction (LVEF), 40 patients underwent treadmill exercise first-pass and bicycle exercise equilibrium radionuclide ventriculography. To determine the frequency of technically adequate treadmill exercise first-pass studies, an additional 128 consecutive patients undergoing treadmill exercise first-pass procedures during stress Tc-99m-labeled sestamibi myocardial perfusion studies were assessed. Methods and Results. The treadmill exercise first-pass procedure used a multicrystal camera and an Am-241 point source to allow for correction of patient motion. Excellent correlations were observed between resting first-pass and resting equilibrium LVEF (r = 0.91; standard error of the estimate = 5.6). A high correlation was also observed between treadmill exercise first-pass and bicycle equilibrium exercise LVEF measurements (r = 0.85, standard error of the estimate = 7.6). Treadmill first-pass LVEF systematically underestimated the bicycle equilibrium LVEF. Intraobserver agreement for rest and exercise first-pass LVEF was high (r values of 0.98 and 0.91, respectively). Of the 168 consecutive treadmill exercise first-pass studies evaluated for technical adequacy, 21 (12.5%) were deemed technically inadequate, with most of the sources of error being avoidable. The frequency of technically adequate studies was as high (87%) in high levels of exercise (Bruce stages 3 and 4) as in lower levels (88%). The findings of this study validate the first-pass treadmill exercise LVEF measurement. Conclusion. This procedure now provides the option for combining the information of peak treadmill exercise LVEF with measurements of exercise myocardial perfusion from the same injection of radioactivity.
引用
收藏
页码:382 / 388
页数:7
相关论文
共 18 条
  • [1] Arrighi James A., 1993, Journal of the American College of Cardiology, V21, p67A
  • [2] TECHNETIUM 99M SESTAMIBI IN THE ASSESSMENT OF CHRONIC CORONARY-ARTERY DISEASE
    BERMAN, DS
    KIAT, H
    VANTRAIN, K
    GARCIA, E
    FRIEDMAN, J
    MADDAHI, J
    [J]. SEMINARS IN NUCLEAR MEDICINE, 1991, 21 (03) : 190 - 212
  • [3] BERMAN DS, 1991, CARDIAC IMAGING COMP, P1097
  • [4] BODENHEIMER MM, 1978, AM J CARDIOL, V47, P718
  • [5] COMBINED EXERCISE RADIONUCLIDE ANGIOCARDIOGRAPHY AND SINGLE PHOTON-EMISSION COMPUTED-TOMOGRAPHY PERFUSION STUDIES FOR ASSESSMENT OF CORONARY-ARTERY DISEASE
    BORGESNETO, S
    COLEMAN, RE
    POTTS, JM
    JONES, RH
    [J]. SEMINARS IN NUCLEAR MEDICINE, 1991, 21 (03) : 223 - 229
  • [6] BORGESNETO S, 1990, J NUCL MED, V31, P1128
  • [7] INCREASED LUNG UPTAKE OF TL-201 DURING EXERCISE MYOCARDIAL IMAGING - CLINICAL, HEMODYNAMIC AND ANGIOGRAPHIC IMPLICATIONS IN PATIENTS WITH CORONARY-ARTERY DISEASE
    BOUCHER, CA
    ZIR, LM
    BELLER, GA
    OKADA, RD
    MCKUSICK, KA
    STRAUSS, HW
    POHOST, GM
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1980, 46 (02) : 189 - 196
  • [8] COMPARISON OF UPRIGHT AND SUPINE BICYCLE EXERCISE IN THE DETECTION AND EVALUATION OF EXTENT OF CORONARY-ARTERY DISEASE BY EQUILIBRIUM RADIONUCLIDE VENTRICULOGRAPHY
    FREEMAN, MR
    BERMAN, DS
    STANILOFF, H
    ELKAYAM, U
    MADDAHI, J
    SWAN, HJC
    FORRESTER, J
    [J]. AMERICAN HEART JOURNAL, 1981, 102 (02) : 182 - 189
  • [9] GROCH MW, 1985, J NUCL MED, V26, P1478
  • [10] SIMULTANEOUS MEASUREMENT OF MYOCARDIAL PERFUSION AND VENTRICULAR-FUNCTION DURING EXERCISE FROM A SINGLE INJECTION OF TC-99M SESTAMIBI IN CORONARY-ARTERY DISEASE
    JONES, RH
    BORGESNETO, S
    POTTS, JM
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1990, 66 (13) : E68 - E71