SUMMARY REPORT FROM THE 1ST INTERNATIONAL WORKSHOP ON SOLUBLE HLA ANTIGENS - PARIS, AUGUST 1992

被引:46
作者
POULETTY, P
FERRONE, S
AMESLAND, F
COHEN, N
WESTHOFF, U
CHARRON, D
SHIMIZU, RM
GROSSEWILDE, H
机构
[1] NEW YORK MED COLL,DEPT MICROBIOL,VALHALLA,NY 10595
[2] HOP ST LOUIS,IMMUNOL & HISTOCOMPATIBIL LAB,F-75010 PARIS,FRANCE
[3] CTR ETUDE POLYMORPH HUMAIN,PARIS,FRANCE
[4] UNIV KLINIKUM ESSEN,INST IMMUNOL,ESSEN,GERMANY
来源
TISSUE ANTIGENS | 1993年 / 42卷 / 01期
关键词
SOLUBLE HLA; HLA; ELISA; MONOCLONAL ANTIBODY; STANDARD; TRANSFECTANT;
D O I
10.1111/j.1399-0039.1993.tb02166.x
中图分类号
Q2 [细胞生物学];
学科分类号
071009 ; 090102 ;
摘要
The First International Workshop on Soluble HLA antigens focused on the comparison of immunoassay procedures for quantitation of soluble HLA (sHLA) class I antigens and the selection of a sHLA class I antigen international standard. Several sets of serum, plasma, and cell culture supernatant specimens were assayed blindly for levels of sHLA class I antigens by 15 participating laboratories using different immunoassay formats. The sandwich ELISA using (i) for antigen capture: an anti-HLA class I heavy chain monoclonal antibody (mAb) specific for a monomorphic epitope, and (ii) for antigen detection: an anti-beta2 microglobulin antibody-enzyme conjugate, was the assay format of choice. There was a high inter-laboratory correlation among the majority of laboratories. All serum and plasma specimens from normal donors, and from a single transplant patient, had detectable levels of sHLA class I antigens. Paired serum and plasma specimens had similar levels of sHLA class I antigens, although plasma sHLA antigens seemed more stable than serum sHLA antigens. sHLA-A2 and sHLA-B7 antigens were detected in all specimens from HLA-A2 and HLA-B7 donors, respectively, using allele-specific ELISAs. No difference in reactivity was observed for quantitation of native sHLA class I antigens whether the capture mAb was TP25.99 (alpha 3 domain-specific) or W6/32 (alpha 2+alpha 3-specific). However, a human-mouse chimeric sHLA class I antigen reacted weakly in assays which used TP25.99 mAb. The wide variation among laboratories in their reporting of mug/ml units pointed to the need for an inter-laboratory standardization based on a calibrated sHLA antigen preparation. T.sB7, an sHLA-B7 antigen derived from a cell line transfected within human beta2 microglobulin and HLA-B7 genes, was accepted as the First sHLA class I Antigen International Standard at the workshop meeting.
引用
收藏
页码:45 / 54
页数:10
相关论文
共 25 条
[21]   SOLUBLE HLA CLASS-I SERUM CONCENTRATIONS INCREASE WITH TRANSPLANT-RELATED COMPLICATIONS AFTER LIVER-TRANSPLANTATION [J].
TILG, H ;
WESTHOFF, U ;
VOGEL, W ;
AULITZKY, WE ;
HEROLD, M ;
MARGREITER, R ;
HUBER, C ;
GROSSEWILDE, H .
JOURNAL OF HEPATOLOGY, 1992, 14 (2-3) :417-419
[22]   QUANTITATION OF SOLUBLE HLA CLASS-II MOLECULES BY AN ENZYME-LINKED-IMMUNOSORBENT-ASSAY [J].
WESTHOFF, U ;
THINNES, FP ;
GOTZ, H ;
GROSSEWILDE, H .
VOX SANGUINIS, 1991, 61 (02) :106-110
[23]  
WESTHOFF U, 1989, TRANSPLANTATION, V48, P891
[24]  
WILSON BS, 1979, J IMMUNOL, V122, P1967
[25]   MEASUREMENT OF SOLUBLE MHC CLASS-I MOLECULES IN RENAL GRAFT PATIENTS - A NONINVASIVE ALLOGRAFT MONITOR [J].
ZAVAZAVA, N ;
LEIMENSTOLL, G ;
MULLERRUCHHOLTZ, W .
JOURNAL OF CLINICAL LABORATORY ANALYSIS, 1990, 4 (06) :426-429