BIOMEDICAL APPLICATIONS OF TUNABLE DIODE-LASER SPECTROMETRY - CORRELATION BETWEEN BREATH CARBON-MONOXIDE AND LOW-LEVEL BLOOD CARBOXYHEMOGLOBIN SATURATION

被引:6
作者
LEE, PS
SCHRECK, RM
HARE, BA
MCGRATH, JJ
机构
[1] LASER PHOTON,DIV ANALYT,ANDOVER,MA
[2] TEXAS TECH UNIV,DEPT PHYSIOL,LUBBOCK,TX 79409
关键词
DIODE LASER SPECTROMETRY; CARBON MONOXIDE; CARBOXYHEMOGLOBIN;
D O I
10.1007/BF02368228
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Tunable diode laser spectrometry was used to measure breath carbon monoxide (CO) concentrations in nonsmoking subjects. Corresponding blood carboxyhemoglobin (COHb) saturations between physiological levels and levels after 1 and 8 hours exposure to 9 ppm CO, the maximum permissible concentration in the air under federal regulations, were also determined. A good linear correlation between breath CO and blood COHb saturation for low levels representing ambient conditions was established, with a correlation coefficient better than 0.999 for the means and 0.945 for the individual data points. Similar studies on the other compounds of concern are also possible using tunable diode laser spectrometry, requiring only a breath sample and with no sample preparation. This technique will facilitate fast, noninvasive environmental health effect and biomedical studies.
引用
收藏
页码:120 / 125
页数:6
相关论文
共 18 条
[1]   PRODUCTION OF CARBON MONOXIDE FROM HEMOGLBIN IN VIVO [J].
COBURN, RF ;
WILLIAMS, WJ ;
WHITE, P ;
KAHN, SB .
JOURNAL OF CLINICAL INVESTIGATION, 1967, 46 (03) :346-&
[2]   ENDOGENOUS CARBON MONOXIDE PRODUCTION IN MAN [J].
COBURN, RF ;
FORSTER, RE ;
BLAKEMORE, WS .
JOURNAL OF CLINICAL INVESTIGATION, 1963, 42 (07) :1172-&
[3]   EFFECT OF ERYTHROCYTE DESTRUCTION ON CARBON MONOXIDE PRODUCTION IN MAN [J].
COBURN, RF ;
FORSTER, RE ;
WILLIAMS, WJ .
JOURNAL OF CLINICAL INVESTIGATION, 1964, 43 (06) :1098-&
[4]   ENDOGENOUS CARBON MONOXIDE PRODUCTION IN PATIENTS WITH HEMOLYTIC ANEMIA [J].
COBURN, RF ;
WILLIAMS, WJ ;
KAHN, SB .
JOURNAL OF CLINICAL INVESTIGATION, 1966, 45 (04) :460-+
[5]  
JONES RH, 1958, J LAB CLIN MED, V5, P553
[6]   APPLICATION OF END-EXPIRED BREATH SAMPLING TO ESTIMATE CARBOXYHEMOGLOBIN LEVELS IN COMMUNITY AIR-POLLUTION EXPOSURE ASSESSMENTS [J].
LAMBERT, WE ;
COLOME, SD ;
WOJCIECHOWSKI, SL .
ATMOSPHERIC ENVIRONMENT, 1988, 22 (10) :2171-2181
[7]   CATABOLISM OF HEME IN-VIVO - COMPARISON OF SIMULTANEOUS PRODUCTION OF BILIRUBIN AND CARBON MONOXIDE [J].
LANDAW, SA ;
CALLAHAN, EW ;
SCHMID, R .
JOURNAL OF CLINICAL INVESTIGATION, 1970, 49 (05) :914-&
[8]   HIGH-RESOLUTION INFRARED DIODE-LASER SPECTROSCOPY FOR ISOTOPE ANALYSIS - MEASUREMENT OF ISOTOPIC CARBON-MONOXIDE [J].
LEE, PS ;
MAJKOWSKI, RF .
APPLIED PHYSICS LETTERS, 1986, 48 (10) :619-621
[9]   TUNABLE DIODE-LASER SPECTROSCOPY FOR ISOTOPE ANALYSIS - DETECTION OF ISOTOPIC CARBON-MONOXIDE IN EXHALED BREATH [J].
LEE, PS ;
MAJKOWSKI, RF ;
PERRY, TA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1991, 38 (10) :966-973
[10]  
LEE PS, 1986, 2ND P INT S SYNTH AP