AORTIC REGURGITATION - QUANTITATION WITH MR IMAGING VELOCITY MAPPING

被引:82
作者
HONDA, N [1 ]
MACHIDA, K [1 ]
HASHIMOTO, M [1 ]
MAMIYA, T [1 ]
TAKAHASHI, T [1 ]
KAMANO, T [1 ]
KASHIMADA, A [1 ]
INOUE, Y [1 ]
TANAKA, S [1 ]
YOSHIMOTO, N [1 ]
MATSUO, H [1 ]
机构
[1] SAITAMA MED CTR,SAITAMA MED SCH,DEPT CARDIOL,KAWAGOE,SAITAMA 350,JAPAN
关键词
AORTA; AORTIC VALVE; MAGNETIC RESONANCE (MR); VASCULAR STUDIES;
D O I
10.1148/radiology.186.1.8416562
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Aortic regurgitation (AR) in five healthy volunteers and 26 patients (mean age, 60.3 years; range, 25-83 years) was quantitatively measured with magnetic resonance (MR) imaging velocity mapping. Cine transverse images of the ascending aorta (32 phases per cardiac cycle) were acquired by using a gradient-echo sequence with a velocity-encoding bipolar pulse applied in the section-selection direction with a 1.5-T MR imaging unit. The aortic flow was calculated by integrating the product of area and mean velocity of the ascending aorta at each phase over a cardiac cycle. The negative and positive velocity values indicated antegrade and regurgitant flow, respectively, which allowed calculation of forward and regurgitant flow. Inter-and intraobserver variation of regurgitant fraction (RF) measurement was small (r = .956, standard error of the estimate [SEE] = 1.2%, n = 31; and r = .998, SEE = 0.35%, n = 10, respectively). RF determined with MR imaging agreed well with Doppler echocardiographic (n = 26) and aortographic (n = 9) grading of AR. Reproducible, quantitative, and noninvasive measurement of AR is possible with MR velocity mapping.
引用
收藏
页码:189 / 194
页数:6
相关论文
共 31 条
[11]   CINE MR IMAGING IN MITRAL REGURGITATION - COMPARISON WITH COLOR DOPPLER FLOW IMAGING [J].
NISHIMURA, T ;
YAMADA, N ;
ITOH, A ;
MIYATAKE, K .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 153 (04) :721-724
[12]  
OHTAKE T, 1987, J NUCL MED, V28, P19
[13]  
OKAMURA M, 1991, JPN J MAGN RESON MED, V3, P203
[14]   COMPARISON OF CINE MR IMAGING WITH DOPPLER ECHOCARDIOGRAPHY FOR THE EVALUATION OF AORTIC REGURGITATION [J].
PFLUGFELDER, PW ;
LANDZBERG, JS ;
CASSIDY, MM ;
CHEITLIN, MD ;
SCHILLER, NB ;
AUFFERMANN, W ;
HIGGINS, CB .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 152 (04) :729-735
[15]   NONINVASIVE EVALUATION OF MITRAL REGURGITATION BY ANALYSIS OF LEFT ATRIAL SIGNAL LOSS IN CINE MAGNETIC-RESONANCE [J].
PFLUGFELDER, PW ;
SECHTEM, UP ;
WHITE, RD ;
CASSIDY, MM ;
SCHILLER, NB ;
HIGGINS, CB .
AMERICAN HEART JOURNAL, 1989, 117 (05) :1113-1119
[16]  
RACKLEY CE, 1986, HEART, P739
[17]   MEASUREMENT OF AORTIC AND MITRAL REGURGITATION BY GATED CARDIAC BLOOD POOL SCANS [J].
RIGO, P ;
ALDERSON, PO ;
ROBERTSON, RM ;
BECKER, LC ;
WAGNER, HN .
CIRCULATION, 1979, 60 (02) :306-312
[18]  
RUBIN DL, 1990, BOOK ABSTRACTS SOC M, P90
[19]   USE OF SINGLE PLANE ANGIOCARDIOGRAMS FOR CALCU9ATION OF LEFT VENTRICULAR VOLUME IN MAN [J].
SANDLER, H ;
DODGE, HT .
AMERICAN HEART JOURNAL, 1968, 75 (03) :325-&
[20]  
SANDLER H, 1963, AM HEART J, V62, P501