The utilization of diode lasers for Raman spectroscopy

被引:15
作者
Angel, SM
Carrabba, M
Cooney, TF
机构
[1] EIC LABS INC,NORWOOD,MA 02062
[2] HAWAII INST GEOPHYS & PLANETOL,SCH OCEAN & EARTH SCI & TECHNOL,HONOLULU,HI 96822
来源
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY | 1995年 / 51卷 / 11期
关键词
D O I
10.1016/0584-8539(95)01443-X
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
The principle of operation and characteristics of diode lasers are briefly reviewed and critically compared to those of other lasers in regard to use as excitation light sources for laser Raman spectroscopy. Relative to other lasers frequently used for Raman spectroscopy, diode lasers have the advantages of smaller size, less interference from most sample fluorescence (compared to green, blue and UV lasers), greater efficiency, lower heat generation, less need for support equipment, potentially longer operating lifetime, virtually continuous tuning capability over approximately 30 nm, and lower cost. The disadvantages include generally lower power, smaller Raman cross section (because of restriction to near-infrared and infrared wavelengths), poor detection for large Stokes Raman shifts, decreased wavelength stability (''mode hopping''), greater beam divergence, decreased human-eye visibility, and (in some cases) decreased coherence. To date, diode lasers have only been used in conjunction with a relatively few Raman studies involving surface-enhanced Raman spectroscopy and remote optical fiber probes. As they become more powerful, stable, and coherent, diode lasers are expected to become more prominent in Raman spectroscopic studies, especially those requiring portable remote systems for process monitoring and selected environmental applications. The ease of use and handling of diode lasers will lend themselves to integration into turn-key Raman system packages which will be used as a routine analytical tool by general chemists.
引用
收藏
页码:1779 / 1799
页数:21
相关论文
共 113 条
[61]   NEAR-INFRARED FOURIER-TRANSFORM RAMAN-SPECTROSCOPY USING FIBER-OPTIC ASSEMBLIES [J].
LEWIS, EN ;
KALASINSKY, VF ;
LEVIN, IW .
ANALYTICAL CHEMISTRY, 1988, 60 (24) :2658-2661
[62]   SURFACE-ENHANCED RAMAN-SPECTROSCOPY OF P-AMINOBENZOIC ACID WITH EXCITATION IN THE VISIBLE AND NEAR-INFRARED SPECTRAL REGION [J].
LIANG, EJ ;
ENGERT, C ;
KIEFER, W .
VIBRATIONAL SPECTROSCOPY, 1993, 6 (01) :79-85
[63]   SURFACE-ENHANCED RAMAN-SCATTERING OF PYRIDINE IN SILVER COLLOIDS EXCITED IN THE NEAR-INFRARED REGION [J].
LIANG, EJ ;
ENGERT, C ;
KIEFER, W .
JOURNAL OF RAMAN SPECTROSCOPY, 1993, 24 (11) :775-779
[64]   STIMULATED OPTICAL EMISSION IN FLUORESCENT SOLIDS .2. SPECTROSCOPY AND STIMULATED EMISSION IN RUBY [J].
MAIMAN, TH ;
EVTUHOV, V ;
HOSKINS, RH ;
DHAENENS, IJ ;
ASAWA, CK .
PHYSICAL REVIEW, 1961, 123 (04) :1151-&
[65]   STIMULATED OPTICAL RADIATION IN RUBY [J].
MAIMAN, TH .
NATURE, 1960, 187 (4736) :493-494
[66]   FIBER OPTIC PROBE FOR REMOTE RAMAN SPECTROMETRY [J].
MCCREERY, RL ;
FLEISCHMANN, M ;
HENDRA, P .
ANALYTICAL CHEMISTRY, 1983, 55 (01) :146-148
[67]  
MCCREERY RL, 1992, P SOC PHOTO-OPT INS, V1637, P208, DOI 10.1117/12.59334
[68]   A SENSITIVE MULTICHANNEL DETECTION SYSTEM FOR SURFACE RAMAN-SPECTROSCOPY [J].
MEIER, M ;
CARRON, KT ;
FLUHR, W ;
WOKAUN, A .
APPLIED SPECTROSCOPY, 1988, 42 (06) :1066-1072
[69]   USE OF AN UNINTENSIFIED CHARGE-COUPLED DEVICE DETECTOR FOR LOW-LIGHT-LEVEL RAMAN-SPECTROSCOPY [J].
MURRAY, CA ;
DIERKER, SB .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1986, 3 (12) :2151-2159
[70]   ELIMINATION OF BACKGROUND IN FIBEROPTIC RAMAN MEASUREMENTS [J].
MYRICK, ML ;
ANGEL, SM .
APPLIED SPECTROSCOPY, 1990, 44 (04) :565-570