QUANTIFICATION OF APOPTOSIS AND NECROSIS BY FLOW-CYTOMETRY

被引:86
作者
ORMEROD, MG [1 ]
SUN, XM [1 ]
BROWN, D [1 ]
SNOWDEN, RT [1 ]
COHEN, GM [1 ]
机构
[1] MRC, TOXICOL UNIT, CARSHALTON SM5 4EF, SURREY, ENGLAND
关键词
D O I
10.3109/02841869309093620
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Apoptosis and necrosis are two important mechanisms of cell death. Several methods have recently been described for quantifying apoptotic cells by flow cytometry. We report a novel method for the quantification and separation of viable normal and apoptotic cells. We have applied this method both to immature rat thymocytes treated with a variety of agents and to a murine haemopoetic cell line after withdrawal of a growth factor. The cells were incubated with two dyes which give fluorescent complexes when bound to DNA, the bis-benzimidazole, Hoechst 33342, and propidium iodide. Three populations were identified and characterized. On excitation with UV radiation, dead cells fluoresced red due to the uptake of propidium iodide whereas apoptotic cells fluoresced bright blue; normal cells showed low blue, low red fluorescence. In this paper, we demonstrate how this method may be used to help to distinguish between cell death by apoptosis and necrosis.
引用
收藏
页码:417 / 424
页数:8
相关论文
共 32 条
[21]   IL3-DEPENDENT MOUSE CLONES THAT EXPRESS B-220 SURFACE-ANTIGEN, CONTAIN IG GENES IN GERM-LINE CONFIGURATION, AND GENERATE LYMPHOCYTES-B INVIVO [J].
PALACIOS, R ;
STEINMETZ, M .
CELL, 1985, 41 (03) :727-734
[22]  
POLLACK A, 1991, FLOW CYTOMETRY, P19
[23]   REGULATION OF APOPTOSIS IN INTERLEUKIN-3-DEPENDENT HEMATOPOIETIC-CELLS BY INTERLEUKIN-3 AND CALCIUM IONOPHORES [J].
RODRIGUEZTARDUCHY, G ;
COLLINS, M ;
LOPEZRIVAS, A .
EMBO JOURNAL, 1990, 9 (09) :2997-3002
[24]   A FLOW-CYTOMETRIC METHOD FOR THE SEPARATION AND QUANTITATION OF NORMAL AND APOPTOTIC THYMOCYTES [J].
SUN, XM ;
SNOWDEN, RT ;
SKILLETER, DN ;
DINSDALE, D ;
ORMEROD, MG ;
COHEN, GM .
ANALYTICAL BIOCHEMISTRY, 1992, 204 (02) :351-356
[25]   DETECTION OF APOPTOSIS OF IMMATURE CD4+8+ THYMOCYTES BY FLOW-CYTOMETRY [J].
SWAT, W ;
IGNATOWICZ, L ;
KISIELOW, P .
JOURNAL OF IMMUNOLOGICAL METHODS, 1991, 137 (01) :79-87
[26]   COMPARATIVE-EVALUATION OF SEVERAL DNA-BINDING DYES IN THE DETECTION OF APOPTOSIS-ASSOCIATED CHROMATIN DEGRADATION BY FLOW-CYTOMETRY [J].
TELFORD, WG ;
KING, LE ;
FRAKER, PJ .
CYTOMETRY, 1992, 13 (02) :137-143
[27]   EVALUATION OF GLUCOCORTICOID-INDUCED DNA FRAGMENTATION IN MOUSE THYMOCYTES BY FLOW-CYTOMETRY [J].
TELFORD, WG ;
KING, LE ;
FRAKER, PJ .
CELL PROLIFERATION, 1991, 24 (05) :447-459
[28]  
WALKER PR, 1991, CANCER RES, V51, P1078
[29]  
Wyllie A H, 1980, Int Rev Cytol, V68, P251
[30]   CHROMATIN CLEAVAGE IN APOPTOSIS - ASSOCIATION WITH CONDENSED CHROMATIN MORPHOLOGY AND DEPENDENCE ON MACROMOLECULAR-SYNTHESIS [J].
WYLLIE, AH ;
MORRIS, RG ;
SMITH, AL ;
DUNLOP, D .
JOURNAL OF PATHOLOGY, 1984, 142 (01) :67-77