3-DIMENSIONAL CONFORMAL PANCREAS TREATMENT - COMPARISON OF 4-FIELD TO 6-FIELD TECHNIQUES

被引:28
作者
HIGGINS, PD [1 ]
SOHN, JW [1 ]
FINE, RM [1 ]
SCHELL, MC [1 ]
机构
[1] UNIV ROCHESTER,CTR CANC,DEPT RADIAT ONCOL,ROCHESTER,NY 14642
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1995年 / 31卷 / 03期
关键词
CONFORMAL RADIOTHERAPY; 3D RADIOTHERAPY; PANCREAS;
D O I
10.1016/0360-3016(94)00380-4
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: We compare practical conformal treatment approaches to pancreatic cancer using 6 and 18 MV photons and contrast those approaches against standard techniques. Methods and Materials: A four-field conformal technique for treating pancreas cancer has been developed using nonopposed 18 MV photons, This approach has been extended to 6 MV photon application by the addition of one to two fields, These techniques have been optimized to increase sparing of normal liver and bowel, compared with opposed-field methods, to improve patient tolerance of high doses. In this study we compare these techniques in a simulated tumor model in a cylindrical phantom, Dose-volume analysis is used to quantify differences between the conformal, nonopposed techniques with conformal, opposed field methods, This model is also used to evaluate the effect of 1-2 cm setup errors on dose-volume coverage. Results: Dose-volume analysis demonstrates that five-to-six field conformal treatments using 6 MV photons provides similar or better dose coverage and normal tissue sparing characteristics as an optimized 18 MV, four-field approach when 1-2 cm margins are included for setup uncertainty, All approaches using nonopposed beam geometry provide significant reduction in the volume of tissue encompassed by the 30-50% isodose surfaces, as compared with four-field box techniques. Conclusions: Three-dimensional (3D) conformal treatments can be designed that significantly improve dose-volume characteristics over conventional treatment designs without costing unacceptable amounts of machine time, Further, deep intraabdominal sites can be adequately accessed and treated on intermediate energy machines with a relatively moderate increase in machine time.
引用
收藏
页码:605 / 609
页数:5
相关论文
共 12 条
[11]   THE ROLE OF UNCERTAINTY ANALYSIS IN TREATMENT PLANNING [J].
URIE, MM ;
GOITEIN, M ;
DOPPKE, K ;
KUTCHER, JG ;
LOSASSO, T ;
MOHAN, R ;
MUNZENRIDER, JE ;
SONTAG, M ;
WONG, JW .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 21 (01) :91-107
[12]  
UM PLAN TREATMENT PL, pR40