SIMPLIFIED NERVE-CELL COUNTING IN THE RAT BRAIN-STEM WITH THE PHYSICAL DISECTOR USING A DRAWING-MICROSCOPE

被引:44
作者
GUNTINASLICHIUS, O
MOCKENHAUPT, J
STENNERT, E
NEISS, WF
机构
[1] UNIV COLOGNE,DEPT ANAT,D-50924 COLOGNE,GERMANY
[2] UNIV COLOGNE,DEPT OTORHINOLARYNGOL,D-50924 COLOGNE,GERMANY
来源
JOURNAL OF MICROSCOPY-OXFORD | 1993年 / 172卷
关键词
PHYSICAL DISECTOR; CELL COUNTING; NEURON; DRAWING-MICROSCOPE; CYTOCHEMISTRY; PARAFFIN SECTIONS;
D O I
10.1111/j.1365-2818.1993.tb03409.x
中图分类号
TH742 [显微镜];
学科分类号
摘要
A simple modification of the physical disector is presented, which is used to count the number of neurons in the hypoglossal nucleus of the rat in a series of paraffin sections. One disector consists of two adjacent sections (6 mu m thick) that have been Nissl-stained with cresyl fast violet. In the first step of the procedure each of the two sections is investigated separately with a drawing-microscope. The boundary of the hypoglossal nucleus and the position of neurons devoid of, or containing a part of, the cell nucleus in the plane of the section are marked on transparent paper. In the second step, these two drawings are placed one upon another, aligned and the number of cell profiles that show a cell nucleus in one but not in both drawings counted. This modification of the disector method for cell counting needs no specialized equipment, simply a light microscope with drawing apparatus, and can be combined with histochemical studies of other sections from the same tissue block.
引用
收藏
页码:177 / 180
页数:4
相关论文
共 18 条
[1]   THE TOTAL NUMBER OF NEURONS IN THE HUMAN NEOCORTEX UNBIASEDLY ESTIMATED USING OPTICAL DISECTORS [J].
BRAENDGAARD, H ;
EVANS, SM ;
HOWARD, CV ;
GUNDERSEN, HJG .
JOURNAL OF MICROSCOPY-OXFORD, 1990, 157 :285-304
[2]   THE IMPACT OF RECENT STEREOLOGICAL ADVANCES ON QUANTITATIVE STUDIES OF THE NERVOUS-SYSTEM [J].
BRAENDGAARD, H ;
GUNDERSEN, HJG .
JOURNAL OF NEUROSCIENCE METHODS, 1986, 18 (1-2) :39-78
[3]   APPLICATION OF THE DISECTOR METHOD IN THE LIGHT MICROSCOPIC QUANTIFICATION OF TYPE-II PNEUMOCYTES IN CONTROL AND OZONE-EXPOSED RATS [J].
DORMANS, JAMA .
JOURNAL OF MICROSCOPY-OXFORD, 1989, 155 :207-211
[4]   STEREOLOGY OF ARBITRARY PARTICLES - A REVIEW OF UNBIASED NUMBER AND SIZE ESTIMATORS AND THE PRESENTATION OF SOME NEW ONES, IN MEMORY OF THOMPSON,WILLIAM,R. [J].
GUNDERSEN, HJG .
JOURNAL OF MICROSCOPY, 1986, 143 :3-45
[5]   THE EFFICIENCY OF SYSTEMATIC-SAMPLING IN STEREOLOGY AND ITS PREDICTION [J].
GUNDERSEN, HJG ;
JENSEN, EB .
JOURNAL OF MICROSCOPY-OXFORD, 1987, 147 :229-263
[6]   AN ACOUSTIC DEPTH ALARM DEVICE TO MONITOR VERTICAL TRANSLATION OF THE MICROSCOPE STAGE - A PRACTICAL OPTICAL DISECTOR, SELECTOR AND UNBIASED BRICK FOR ROUTINE LIGHT-MICROSCOPY [J].
LAROYE, GJ ;
TAYLOR, WB .
JOURNAL OF MICROSCOPY, 1992, 167 :279-286
[7]  
LICHIUS OG, 1992, EUR J NEUROSCI S, V5, P132
[8]   THE DOUBLE DISECTOR - UNBIASED STEREOLOGICAL ESTIMATION OF THE NUMBER OF PARTICLES INSIDE OTHER PARTICLES [J].
MARCUSSEN, N .
JOURNAL OF MICROSCOPY-OXFORD, 1992, 165 :417-426
[9]  
MATHERON G, 1971, CAHIERS CMM FONTAINE, V5
[10]  
MATTFELDT T, 1990, STEREOLOGISCHE METHO, V52