CORRELATIONS BETWEEN MERCURIC IODIDE PHOTOLUMINESCENCE SPECTRA AND NUCLEAR-DETECTOR PERFORMANCE

被引:16
作者
BAO, XJ
SCHLESINGER, TE
JAMES, RB
HARVEY, SJ
CHENG, AY
GERRISH, V
ORTALE, C
机构
[1] SANDIA NATL LABS,DIV ADV MAT RES,LIVERMORE,CA 94550
[2] EG&G ENERGY MEASUREMENTS INC,GOLETA,CA 93116
基金
美国国家科学基金会;
关键词
D O I
10.1016/0168-9002(92)90609-8
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Low temperature photoluminescence spectroscopy was performed on a variety of HgI2 samples and also on graded HgI2 nuclear detectors. Correlations were found between features in the photoluminescence spectra and a crystal's ability to produce high-quality detectors. The intensity of a broad emission band centered at 6200 angstrom (designated as band 3) is weaker in crystals that yield high-quality detectors. Therefore, the defects responsible for this emission band are undesirable in the fabrication of HgI2 nuclear detectors. The measurements also revealed that stronger emission in the exciton region (designated as band 1) is associated with crystals which Produce high-quality detectors, indicating that a high degree of structural perfection is important for HgI2 detector applications. These correlations, together with. earlier results from studies of processing-induced defects, lead to suggestions regarding improvement of the manufacturing yield of high-quality HgI2 detectors.
引用
收藏
页码:194 / 201
页数:8
相关论文
共 34 条
[1]  
AKOPYAN I, 1975, PHYS STATUS SOLIDI B, V70, P353, DOI 10.1002/pssb.2220700137
[2]  
AKOPYAN IK, 1987, FIZ TVERD TELA, V29, P238
[3]   WHAT CAN BE EXPECTED FROM HIGH-Z SEMICONDUCTOR-DETECTORS [J].
ARMANTROUT, GA ;
SWIERKOWSKI, SP ;
SHEROHMAN, JW ;
YEE, JH .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1977, 24 (01) :121-125
[4]  
BAO XH, UNPUB
[5]  
BAO XJ, 1990, MATER RES SOC SYMP P, V163, P1027
[6]   HIGH-RESOLUTION 4.2 K NEAR BAND-GAP PHOTOLUMINESCENCE SPECTRUM OF MERCURIC IODIDE [J].
BAO, XJ ;
SCHLESINGER, TE ;
JAMES, RB ;
ORTALE, C ;
VANDENBERG, L .
JOURNAL OF APPLIED PHYSICS, 1990, 68 (06) :2951-2954
[7]   STUDY OF SEMITRANSPARENT PALLADIUM CONTACTS ON MERCURIC IODIDE BY PHOTOLUMINESCENCE SPECTROSCOPY AND THERMALLY STIMULATED CURRENT MEASUREMENTS [J].
BAO, XJ ;
SCHLESINGER, TE ;
JAMES, RB ;
GENTRY, GL ;
CHENG, AY ;
ORTALE, C .
JOURNAL OF APPLIED PHYSICS, 1991, 69 (08) :4247-4252
[8]   INVESTIGATION OF COPPER ELECTRODES FOR MERCURIC IODIDE DETECTOR APPLICATIONS [J].
BAO, XJ ;
SCHLESINGER, TE ;
JAMES, RB ;
STULEN, RH ;
ORTALE, C ;
VANDENBERG, L .
JOURNAL OF APPLIED PHYSICS, 1990, 67 (12) :7265-7267
[9]   INCORPORATION OF DEFECTS DURING PROCESSING OF MERCURIC IODIDE DETECTORS [J].
BAO, XJ ;
SCHLESINGER, TE ;
JAMES, RB ;
STULEN, RH ;
ORTALE, C ;
CHENG, AY .
JOURNAL OF APPLIED PHYSICS, 1990, 68 (01) :86-92
[10]   HIGH-ENERGY GAMMA SPECTRA DETECTED WITH IMPROVED HGL2 SPECTROMETERS AT ROOM-TEMPERATURE [J].
BEINGLASS, I ;
DISHON, G ;
HOLZER, A ;
OFER, S ;