SIMULTANEOUS MULTISITE EPR SPECTROSCOPY IN-VIVO

被引:61
作者
SMIRNOV, AI
NORBY, SW
CLARKSON, RB
WALCZAK, T
SWARTZ, HM
机构
[1] UNIV ILLINOIS,DEPT MED,URBANA,IL 61801
[2] UNIV ILLINOIS,DEPT VET MED,URBANA,IL 61801
关键词
ELECTRON PARAMAGNETIC RESONANCE; OXIMETRY; CARBONACEOUS MATERIALS; MYOCARDIUM;
D O I
10.1002/mrm.1910300210
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A gradient technique to measure electron paramagnetic resonance spectra simultaneously at several different locations is described. The technique is based on the use of point probes containing paramagnetic centers. The value of the magnetic field gradient is chosen to be sufficient to separate the EPR signals from the different paramagnetic probes yet at the same time small enough to change only minimally the shape of individual signals. The conditions to apply this technique are considered in detail. When experimental data have a high signal-to-noise ratio, the lineshape distortion induced by the gradient can be corrected with the aid of a known distribution function of paramagnetic centers within the probe. The maximum entropy deconvolution algorithm is successfully applied for the correction of significantly distorted lines. The technique is experimentally tested and applied to measure the concentration of oxygen in hypertrophied rat myocardium and normal rat kidney in vivo by low frequency EPR (L-band, 1.2 GHz). Two types of EPR oxygen-sensitive probes-lithium phthalocyanine crystals and synthetic carbohydrate chars-were used.
引用
收藏
页码:213 / 220
页数:8
相关论文
共 25 条
[1]   EFFECT OF OXYGEN ON PHTHALOCYANINE RADICALS .1. ESR STUDY OF LITHIUM PHTHALOCYANINE SPIN SPECIES AT DIFFERENT OXYGEN CONCENTRATIONS [J].
BENSEBAA, F ;
ANDRE, JJ .
JOURNAL OF PHYSICAL CHEMISTRY, 1992, 96 (14) :5739-5745
[2]  
BOYER SJ, 1992, 66TH COLL SURF SCI S
[3]  
BOYER SJ, 1992, THESIS U ILLINOIS UR
[4]   DETECTION OF DIFFUSION AND DISTRIBUTION OF OXYGEN BY FAST-SCAN ELECTRON-PARAMAGNETIC-RES IMAGING [J].
DEMSAR, F ;
WALCZAK, T ;
MORSE, PD ;
BACIC, G ;
ZOLNAI, Z ;
SWARTZ, HM .
JOURNAL OF MAGNETIC RESONANCE, 1988, 76 (02) :224-231
[5]  
EATON GR, 1991, EPR IMAGING INVIVO E
[6]   SELECTIVE ISOTOPIC LABELING OF A NITROXIDE SPIN LABEL TO ENHANCE SENSITIVITY FOR T2 OXYMETRY [J].
HALPERN, HJ ;
PERIC, M ;
NGUYEN, TD ;
SPENCER, DP ;
TEICHER, BA ;
LIN, YJ ;
BOWMAN, MK .
JOURNAL OF MAGNETIC RESONANCE, 1990, 90 (01) :40-51
[7]  
Herman G. T., 1980, IMAGE RECONSTRUCTION
[8]  
MOUSSAVI M, 1991, 33RD ROCK MOUNT C AN
[9]  
Nilges M.J., 1989, PHYS MEDICA, V5, P195
[10]  
NORBY SW, 1991, 10TH ANN SCI M EXH S