NOVEL MERCURY-COATED CARBON-FIBER VOLTAMMETRIC DETECTOR FOR USE IN ADSORPTIVE STRIPPING FLOW-ANALYSIS

被引:13
作者
DELPOZO, JA [1 ]
COSTAGARCIA, A [1 ]
TUNONBLANCO, P [1 ]
机构
[1] UNIV OVIEDO,DEPT QUIM FIS & ANALIT,E-33006 OVIEDO,SPAIN
关键词
VOLTAMMETRY; FLOW SYSTEM; MERCURY-COATED CARBON FIBER; MITOXANTRONE;
D O I
10.1016/0003-2670(94)80100-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The preparation and application of a novel mercury-coated carbon fibre flow microelectrode are reported. The possibility to use this device in a flow system combined with alternating current (ac) stripping voltammetry is also demonstrated using mitoxantrone (MXT) as probe compound. The electrode is easy to prepare. Special analytical advantages have been observed when a.c. stripping voltammetry is applied to the adsorbed molecule on the electrode due to the reversibility of the electrochemical process. Once the operating system has been optimized a limit of detection for mitoxantrone of 4.5 x 10(-11) M was found. Manipulation of flow conditions allows the study of different concentration ranges. The direct analysis of serum samples without sample pretreatment, is also discussed and provided a linear calibration range between 4.5 X 10(-7) M and 4.5 x 10(-6) M.
引用
收藏
页码:169 / 176
页数:8
相关论文
共 26 条
[1]   VOLTAMMETRIC DETERMINATION OF DOXORUBICIN IN URINE BY ADSORPTIVE PRECONCENTRATION AND FLOW-INJECTION ANALYSIS [J].
CHANEY, EN ;
BALDWIN, RP .
ANALYTICA CHIMICA ACTA, 1985, 176 (OCT) :105-112
[2]   NOVEL CARBON-FIBER ELECTROCHEMICAL DETECTOR FOR USE IN LIQUID-CHROMATOGRAPHY [J].
CHI, H ;
WANG, YP ;
ZHOU, TH ;
JIN, CL .
ANALYTICA CHIMICA ACTA, 1990, 235 (02) :273-277
[3]  
CORTINA JC, 1992, ANAL CHIM ACTA, V256, P231
[4]  
CORTINAVILLAR JC, 1993, TALANTA, V40, P333
[5]   ADSORPTIVE STRIPPING VOLTAMMETRY ON MERCURY-COATED CARBON-FIBER ULTRAMICROELECTRODES [J].
DELPOZO, JA ;
GARCIA, AC ;
BLANCO, PT .
ANALYTICA CHIMICA ACTA, 1993, 273 (1-2) :101-109
[6]   ELECTROANALYTICAL APPLICATIONS OF CARBON-FIBER ELECTRODES [J].
EDMONDS, TE .
ANALYTICA CHIMICA ACTA, 1985, 175 (SEP) :1-22
[7]  
FLEISCHMANN M, 1985, J PHYS CHEM-US, V89, P5330
[8]   RAPID-SCANNING ELECTROCHEMICAL DETECTOR WITH MICRO WORKING ELECTRODE FOR MICRO HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
GOTO, M ;
SHIMADA, K .
CHROMATOGRAPHIA, 1986, 21 (11) :631-634
[9]   LIQUID-CHROMATOGRAPHY OF VITAMIN-B6 WITH ELECTROCHEMICAL DETECTION USING A CARBON-FIBER ELECTRODE [J].
HOU, WY ;
JI, HM ;
WANG, EK .
ANALYTICA CHIMICA ACTA, 1990, 230 (01) :207-211
[10]  
HUILIANG H, 1987, ANAL CHIM ACTA, V193, P61