EFFECTS OF LEFT-VENTRICULAR PRESSURE ON SONICATED ALBUMIN MICROBUBBLES - EVALUATION USING AN ISOLATED RABBIT HEART MODEL

被引:24
作者
MORAVI, V [1 ]
SHROFF, SG [1 ]
ROBINSON, KA [1 ]
NG, AF [1 ]
CHOLLEY, BP [1 ]
MARCUS, RH [1 ]
LANG, RM [1 ]
机构
[1] UNIV CHICAGO,MED CTR,DEPT MED,NONINVAS CARDIAC IMAGING LABS,CARDIOL SECT,CHICAGO,IL 60637
关键词
D O I
10.1016/0735-1097(94)90187-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. We used an isolated, crystalloid-perfused rabbit heart model to test the hypothesis that the phasic changes in left ventricular contrast are due to bubble compression and decompression during systole and diastole, respectively. Background. Contrast enhancement of the left ventricular cavity has been shown to decrease during ventricular systole. This phenomenon has been attributed to pressure-induced microbubble destruction. Such destruction, if confirmed, would severely confound the quantitative interpretation of contrast echocardiographic data. Methods. A fixed volume of contrast solution (5% human albumin and Albunex, similar to 400:1 ratio) was introduced into a latex balloon placed within the left ventricular cavity of an isolated paced rabbit heart preparation (n = 12). Instantaneous left ventricular pressure was measured using a high fidelity microtip catheter and digitized on-line. The beating heart was placed in a water tank, and ultrasound images were obtained using a 7.5-MHz transducer and were recorded and digitized oh-line at 12 frames/s. Simultaneously, the pacing signal was used for gated on-line acquisition of end-diastolic frames. A simple theoretic model based on surface tension physical principles was used to predict changes in bubble size and, consequently, the reflection intensity in response to the measured changes in left ventricular pressure. Results. We found that under peak left ventricular systolic pressures ranging from 89 to 155 mm Hg, 1) end-diastolic videointensity decreased by 8 +/- 6% (mean +/- SD) over 25 consecutive heart beats; and 2) intracyclic variations in measured videointensity were in close agreement with the theoretic calculations: 80.1 +/- 2.9% versus 80.2 +/- 4.6% of diastolic videointensity at systole. Conclusions. The major cause of systolic decrease in contrast enhancement is periodic bubble compression (as opposed to bubble destruction) induced by high systolic pressures. The minor progressive decrease in end-diastolic videointensity reflects the degree of instability of Albunex microbubbles under left ventricular pressures. However, the clinical impact of these destructive effects is likely to be only minor because of the rapid transit of microbubbles through the left heart chambers and myocardial microcirculation.
引用
收藏
页码:1779 / 1785
页数:7
相关论文
共 16 条
[1]  
CHEN MH, 1994, J AM COLL CARDIOL, V23, pA25
[2]   PRINCIPLES AND RECENT DEVELOPMENTS IN ULTRASOUND CONTRAST AGENTS [J].
DEJONG, N ;
TENCATE, FJ ;
LANCEE, CT ;
ROELANDT, JRTC ;
BOM, N .
ULTRASONICS, 1991, 29 (04) :324-330
[3]  
KELLER MW, 1989, CIRC RES, V65, P1
[4]  
Morse P. M., 1968, THEORETICAL ACOUSTIC, P400
[5]  
MOTTLEY J, 1990, CIRCULATION, V82, P28
[6]   CONTRAST AGENTS IN DIAGNOSTIC ULTRASOUND [J].
OPHIR, J ;
PARKER, KJ .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1989, 15 (04) :319-333
[7]  
Powsner S M, 1986, Am J Physiol Imaging, V1, P124
[8]  
SEARS FW, 1958, MECHANICS WAVE MOTIO, P368
[9]  
SHANDAS R, 1990, CIRCULATION, V82, P95
[10]   INTRAVENOUS CONTRAST ECHOCARDIOGRAPHY WITH USE OF SONICATED ALBUMIN IN HUMANS - SYSTOLIC DISAPPEARANCE OF LEFT-VENTRICULAR CONTRAST AFTER TRANSPULMONARY TRANSMISSION [J].
SHAPIRO, JR ;
REISNER, SA ;
LICHTENBERG, GS ;
MELTZER, RS .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 16 (07) :1603-1607