TIME-DOMAIN DIGITAL-FILTER TO IMPROVE SIGNAL-TO-NOISE RATIO IN RESPIRATORY IMPEDANCE MEASUREMENTS

被引:18
作者
FARRE, R
ROTGER, M
NAVAJAS, D
机构
[1] Lab. Biofisica i Bioenginyeria, Facultat de Medicina, Universitat de Barcelona, Barcelona, 08028, Zona Universitana Pedralbes
关键词
BANDPASS FILTER; DIGITAL FILTER; FORCED EXCITATION; NOISE CANCELING; PSEUDORANDOM SIGNAL; PULMONARY MECHANICS; RESPIRATORY IMPEDANCE; SIGNAL-TO-NOISE RATIO;
D O I
10.1007/BF02446291
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The mechanical impedance of the respiratory system Z(rs) is usually measured by forced excitation while the patient breathes spontaneously. Pressure and flow signals due to breathing contaminate the excitation signals, leading to a poor signal-to-noise ratio (SNR) and thus to errors in impedance estimation, especially at low frequencies (up to 8 Hz). To enhance SNR in the recorded signals we designed an infinite impulse response digital filter for the frequent case in which the excitation is pseudorandom. The algorithm is based on narrowband second-order bandpass elements centred at the excitation frequencies. The performance of the filter was assessed in a simulation study by superposing forced excitation signals (2-32 Hz) from a reference model and the signals of breathing recorded from 16 subjects. When compared with a conventional high-pass filtering, the devised filtering resulted in an increase in SNR which was almost constant over the whole frequency band: 6.30 +/- 0.98 dB (mean +/- SD). This improvement in SNR was reflected in an increase in the number of subjects for which the corresponding coherence Y2 attained a value greater than the conventional threshold of acceptability (Y2 = 0.95). At the lowest frequency (2 Hz) only two (12.5 per cent) simulated subjects had Y2 greater-than-or-equal-to 0.95 with the conventional high-pass filtering. By contrast, when using the devised comb filter the number of subjects with Y2 greater-than-or-equal-to 0.95 increased up to 13 (81 per cent). The results obtained suggest that this filter may be useful to improve SNR and thus Z(rs) estimation.
引用
收藏
页码:18 / 24
页数:7
相关论文
共 20 条
[11]   DESIGN OF DIGITAL NOTCH FILTERS [J].
HIRANO, K ;
NISHIMURA, S ;
MITRA, SK .
IEEE TRANSACTIONS ON COMMUNICATIONS, 1974, CO22 (07) :964-970
[12]   COMPUTATION OF RESPIRATORY IMPEDANCE FROM FORCED SINUSOIDAL OSCILLATIONS DURING BREATHING [J].
HOROWITZ, JG ;
SIEGEL, SD ;
PRIMIANO, FP ;
CHESTER, EH .
COMPUTERS AND BIOMEDICAL RESEARCH, 1983, 16 (06) :499-521
[13]   NEW METHOD TO DETERMINE FREQUENCY-CHARACTERISTICS OF RESPIRATORY SYSTEM [J].
LANDSER, FJ ;
NAGELS, J ;
DEMEDTS, M ;
BILLIET, L ;
VANDEWOESTIJNE, KP .
JOURNAL OF APPLIED PHYSIOLOGY, 1976, 41 (01) :101-106
[15]   PULMONARY MECHANICS BY SPECTRAL ANALYSIS OF FORCED RANDOM NOISE [J].
MICHAELSON, ED ;
GRASSMAN, ED ;
PETERS, WR .
JOURNAL OF CLINICAL INVESTIGATION, 1975, 56 (05) :1210-1230
[16]   A NEW ESTIMATOR TO MINIMIZE THE ERROR DUE TO BREATHING IN THE MEASUREMENT OF RESPIRATORY IMPEDANCE [J].
NAVAJAS, D ;
FARRE, R ;
ROTGER, M ;
PESLIN, R .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1988, 35 (12) :1001-1005
[17]   TOTAL RESPIRATORY INPUT AND TRANSFER IMPEDANCES IN HUMANS [J].
PESLIN, R ;
DUVIVIER, C ;
GALLINA, C .
JOURNAL OF APPLIED PHYSIOLOGY, 1985, 59 (02) :492-501
[18]  
PESLIN R, 1986, HDB PHYSL 1, V3
[19]   A SIMPLE PROGRAM FOR A PHASELESS RECURSIVE DIGITAL-FILTER [J].
PYNSENT, PB ;
HANKA, R .
JOURNAL OF BIOMEDICAL ENGINEERING, 1982, 4 (03) :252-254
[20]   MODIFIED MEASUREMENT OF RESPIRATORY RESISTANCE BY FORCED OSCILLATION DURING NORMAL BREATHING [J].
STANESCU, DC ;
FESLER, R ;
VERITER, C ;
FRANS, A ;
BRASSEUR, L .
JOURNAL OF APPLIED PHYSIOLOGY, 1975, 39 (02) :305-311