BIOMECHANICAL COMPARISON OF THE SLIDING HIP SCREW AND THE DOME PLUNGER

被引:25
作者
CHOUEKA, J [1 ]
KOVAL, KJ [1 ]
KUMMER, FJ [1 ]
CRAWFORD, G [1 ]
ZUCKERMAN, JD [1 ]
机构
[1] HOSP JOINT DIS & MED CTR, INST ORTHOPAED, DEPT BIOENGN, NEW YORK, NY 10003 USA
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 1995年 / 77B卷 / 02期
关键词
D O I
10.1302/0301-620X.77B2.7706347
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We studied the biomechanical behaviour of three sliding fixation devices for trochanteric femoral fractures, These mere a titanium alloy sideplate and lag screw, a titanium alloy sideplate and dome plunger with cement augmentation, and a stainless-steel sideplate and lag screw. We used 18 mildly osteoporotic cadaver femora, randomly assigned to one of the three fixation groups, Four displacement and two strain gauges were fixed to each specimen, and each femur was first tested intact (control), then as a two-part fracture and then as a four-part intertrochanteric fracture. A range of physiological loads was applied to determine load-bearing, load-sharing and head displacement. The four-part-fracture specimens were subsequently tested to failure to determine maximum fixation strengths and modes of failure. The dome-plunger group failed at a load 50% higher than that of the stainless-steel lag-screw group (p < 0.05) and at a load 20% higher than that of the titanium-alloy lag-screw group (NS), All 12 lag-screw specimens failed by cut-out through the femoral head or neck, but none of the dome-plunger group showed movement within the femoral head when tested to failure, Strain-gauge analysis showed that the dome plunger produced considerably less strain in the inferior neck and calcar region than either of the lag screws, Inferior displacement of the femoral head was greatest for the dome-plunger group, and was due to sliding of the plunger. The dome plunger with cement augmentation was able to support higher loads and did not fail by cut-out through the femoral head, Its sliding potential was maintained, retaining the biomechanical advantages of the sliding screw.
引用
收藏
页码:277 / 283
页数:7
相关论文
共 30 条
[21]  
Meislin R J, 1990, J Orthop Trauma, V4, P130, DOI 10.1097/00005131-199004020-00005
[22]  
MUHR G, 1979, CLIN ORTHOP RELAT R, P41
[23]  
MULLER ME, 1962, ARCH ORTHOP UNFALL C, V64, P513
[24]   FUNCTIONAL OUTCOME AFTER INTERTROCHANTERIC FRACTURES OF THE FEMUR - DOES THE IMPLANT MATTER - A PROSPECTIVE-STUDY OF 100 CONSECUTIVE CASES [J].
PITSAER, E ;
SAMUEL, AW .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1993, 24 (01) :35-36
[25]  
Rokito Andrew S., 1993, Contemporary Orthopaedics, V26, P349
[26]   A BIOMECHANICAL EVALUATION OF THE GAMMA-NAIL [J].
ROSENBLUM, SF ;
ZUCKERMAN, JD ;
KUMMER, FJ ;
TAM, BS .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (03) :352-357
[27]   SLIDING HIP SCREWS - MODES OF FAILURE [J].
SIMPSON, AHRW ;
VARTY, K ;
DODD, CAF .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1989, 20 (04) :227-231
[28]   CHANGES IN TRABECULAR PATTERN OF UPPER END OF FEMUR AS AN INDEX OF OSTEOPOROSIS [J].
SINGH, M ;
NAGRATH, AR ;
MAINI, PS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1970, A 52 (03) :457-&
[29]  
Wainer R A, 1990, J Orthop Trauma, V4, P58
[30]   BIOMECHANICAL ANALYSIS OF THE DYNAMIC HIP SCREW IN THE TREATMENT OF INTERTROCHANTERIC FRACTURES [J].
WU, CC ;
SHIH, CH .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1991, 110 (06) :307-310