POSTOPERATIVE FLOW CHARACTERISTICS OF LEFT INTERNAL THORACIC ARTERY GRAFTS

被引:55
作者
NASU, M [1 ]
AKASAKA, T [1 ]
OKAZAKI, T [1 ]
SHINKAI, M [1 ]
FUJIWARA, H [1 ]
SONO, J [1 ]
OKADA, Y [1 ]
MIYAMOTO, S [1 ]
NISHIUCHI, S [1 ]
YOSHIKAWA, J [1 ]
SHOMURA, T [1 ]
机构
[1] KOBE CITY GEN HOSP,DEPT CARDIOL,KOBE,HYOGO 650,JAPAN
关键词
D O I
10.1016/0003-4975(94)00795-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Twenty patients whose left internal thoracic artery (LITA) was anastomosed to the left anterior descending artery (LAD) underwent postoperative coronary angiography and Doppler ultrasound velocimetry. During angiography, the diameter of the LITA conduit was measured at three points: proximal, mid, and distal. The degree of left anterior descending artery stenosis proximal to the anastomotic site was evaluated by densitometry. The LITA now velocity pattern was obtained at the three points to calculate the total, systolic, and diastolic flow volume. There were significant differences in the total LITA now among the three points (proximal, 36.0 +/- 17.2 mL/min; mid, 29.9 +/- 15.2 mL/min; distal, 27.2 +/- 14.0 mL/min; p < 0.001 between the proximal and the mid or distal portions). The degree of left anterior descending artery stenosis affected the distal LITA now and diameter (r = 0.823 and 0.811, respectively). There were significant differences in the systolic LITA flow among the three points (proximal, 13.2 +/- 6.5 mL/min; mid, 8.1 +/- 4.7 mL/min; distal, 5.6 +/- 3.4 mL/min; p < 0.001 between the proximal and the mid or distal portions). However, there was no statistically significant difference in the diastolic LITA flow among the three points (proximal, 22.9 +/- 11.0 mL/min; mid, 21.7 +/- 10.8 mL/min; distal, 21.6 +/- 10.8 mL/min). We conclude that a lower degree of LAD stenosis significantly reduces the LITA flow inducing the string phenomenon. Additionally, during the diastolic phase, the LITA graft transports the blood primarily to the coronary artery but not to the side branches. Therefore, the steal phenomenon might not apply in the setting of an LITA graft.
引用
收藏
页码:154 / 161
页数:8
相关论文
共 25 条
[11]  
GRONDIN CM, 1984, CIRCULATION, V70, P208
[12]  
HE GW, 1993, J THORAC CARDIOV SUR, V106, P406
[13]  
IVERT T, 1988, J THORAC CARDIOV SUR, V96, P1
[14]   FLOW CAPACITIES OF ARTERIAL GRAFTS FOR CORONARY-ARTERY BYPASS-GRAFTING [J].
KAWASUJI, M ;
TEDORIYA, T ;
TAKEMURA, H ;
SAKAKIBARA, N ;
TAKI, J ;
WATANABE, Y .
ANNALS OF THORACIC SURGERY, 1993, 56 (04) :957-962
[15]   ANGIOGRAPHIC DEMONSTRATION OF NO-FLOW ANATOMICAL PATENCY OF INTERNAL THORACIC CORONARY-ARTERY BYPASS GRAFTS [J].
KITAMURA, S ;
KAWACHI, K ;
SEKI, T ;
SAWABATA, N ;
MORITA, R ;
KAWATA, T .
ANNALS OF THORACIC SURGERY, 1992, 53 (01) :156-159
[16]   EFFECT OF CHRONIC NATIVE FLOW COMPETITION ON INTERNAL THORACIC ARTERY GRAFTS [J].
LUST, RM ;
ZERI, RS ;
SPENCE, PA ;
HOPSON, SB ;
SUN, YS ;
OTAKI, M ;
JOLLY, SR ;
MEHTA, PM ;
CHITWOOD, WR .
ANNALS OF THORACIC SURGERY, 1994, 57 (01) :45-50
[17]   EFFECTS OF INTERNAL MAMMARY ARTERY DISSECTION ON PHRENIC-NERVE PERFUSION AND FUNCTION [J].
OBRIEN, JW ;
JOHNSON, SH ;
VANSTEYN, SJ ;
CRAIG, DM ;
SHARPE, RE ;
MAUNEY, MC ;
SMITH, PK .
ANNALS OF THORACIC SURGERY, 1991, 52 (02) :182-188
[18]  
PELIAS AJ, 1985, J THORAC CARDIOV SUR, V90, P794
[19]   STEAL PHENOMENON CAUSED BY A PARALLEL BRANCH OF THE INTERNAL MAMMARY ARTERY [J].
SCHMID, C ;
HEUBLEIN, B ;
REICHELT, S ;
BORST, HG .
ANNALS OF THORACIC SURGERY, 1990, 50 (03) :463-464
[20]   ALTERATIONS OF PHASIC CORONARY-ARTERY FLOW VELOCITY IN HUMANS DURING PERCUTANEOUS CORONARY ANGIOPLASTY [J].
SEGAL, J ;
KERN, MJ ;
SCOTT, NA ;
KING, SB ;
DOUCETTE, JW ;
HEUSER, RR ;
OFILI, E ;
SIEGEL, R .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 20 (02) :276-286