ION-EXCHANGE VOLTAMMETRY OF COPPER IONS IN CHLORIDE MEDIA AT GLASSY-CARBON ELECTRODES MODIFIED WITH POLYCATIONIC IONOMERS

被引:31
作者
UGO, P
MORETTO, LM
MAZZOCCHIN, GA
机构
[1] Department of Physical Chemistry, University of Venice, I-30123 Venice
关键词
COPPER; GLASSY CARBON ELECTRODES; POLYCATIONIC IONOMER COATINGS; SPECIATION;
D O I
10.1016/0003-2670(93)80162-E
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Perfluorinated polycationic polymers (Tosflex) were applied for preparing polymer-modified electrodes able to preconcentrate anionic complexes of Cu+ electrogenerated in situ at the electrode/polymer interface by reducing Cu2+ solutions in the presence of chloride ions. The species incorporated into the polymeric coating, namely CuCl2-, was detected by a suitable linear sweep voltammetric reoxidation scan. The dependence of the reoxidation peak current on experimental parameters such as amount of modifier, electrogeneration-preconcentration time and solution concentrations of Cu2+ and Cl- was studied. The possibility of applying Tosflex-modified electrodes to copper speciation studies was also examined. In particular, the influence on the ion-exchange voltammetric responses of some amino acids such as histidine, glycine and glutamic acid which, at the pH employed in this study, carry positive, neutral and negative ionic charges, respectively, is discussed. Some of the advantages and limitations of Tosflex-modified electrodes compared with Nafion-coated electrodes and the hanging mercury drop electrode are critically evaluated.
引用
收藏
页码:229 / 236
页数:8
相关论文
共 32 条
[21]   MEASUREMENT OF NANOMOLAR DOPAMINE DIFFUSION USING LOW-NOISE PERFLUORINATED IONOMER COATED CARBON-FIBER MICROELECTRODES AND HIGH-SPEED CYCLIC VOLTAMMETRY [J].
RICE, ME ;
NICHOLSON, C .
ANALYTICAL CHEMISTRY, 1989, 61 (17) :1805-1810
[22]   DYNAMIC CONSEQUENCES OF IONIC PERMSELECTIVITY - RAPID EJECTION FROM NAFION COATINGS OF ANIONS GENERATED ELECTROCHEMICALLY FROM CATIONIC PRECURSORS [J].
SHU, CF ;
ANSON, FC .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1990, 112 (25) :9227-9232
[23]  
Smith R. M., 1989, CRITICAL STABILITY C, V6, DOI DOI 10.1007/978-1-4615-6764-6
[24]   WATER SORPTION AND CATION-EXCHANGE SELECTIVITY OF A PERFLUOROSULFONATE ION-EXCHANGE POLYMER [J].
STECK, A ;
YEAGER, HL .
ANALYTICAL CHEMISTRY, 1980, 52 (08) :1215-1218
[25]  
STUMM W, 1975, CHEM OCEANOGRAPHY, V1, pCH3
[26]   ION-EXCHANGE SELECTIVITY OF NAFION FILMS ON ELECTRODE SURFACES [J].
SZENTIRMAY, MN ;
MARTIN, CR .
ANALYTICAL CHEMISTRY, 1984, 56 (11) :1898-1902
[27]   THE EQUILIBRIUM SPECIATION OF DISSOLVED COMPONENTS IN FRESH-WATER AND SEAWATER AT 25-DEGREES-C AND 1 ATM PRESSURE [J].
TURNER, DR ;
WHITFIELD, M ;
DICKSON, AG .
GEOCHIMICA ET COSMOCHIMICA ACTA, 1981, 45 (06) :855-881
[28]   ELECTROCHEMISTRY OF YB3+ AND EU3+ AT NAFION MODIFIED ELECTRODES [J].
UGO, P ;
BALLARIN, B ;
DANIELE, S ;
MAZZOCCHIN, GA .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1990, 291 (1-2) :187-199
[29]  
UGO P, 1991, J ELECTROANAL CHEM, V244, P29
[30]  
WANG J, 1989, ELECTROANALYTICAL CH, V16, P53