AN ION-EXCHANGE SEPARATION OF CU2+, CD2+, PB2+ AND TL+ ON SILICA-GEL WITH POLAROGRAPHIC DETECTION

被引:16
作者
JANOS, P [1 ]
STULIK, K [1 ]
PACAKOVA, V [1 ]
机构
[1] CHARLES UNIV, DEPT ANALYT CHEM, CS-12840 PRAGUE 2, CZECHOSLOVAKIA
关键词
D O I
10.1016/0039-9140(91)80294-A
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The HPLC separation of heavy metal cations was studied with a column packed with Separon SGX silica gel. The retention of the cations is controlled by an ion-exchange mechanism. The ion-exchange capacity is primarily dependent on the mobile phase pH. The analyte retention is further affected by the type and concentration of the complexing agent present and of the counterion. The effect of acetate, tartrate and alpha-hydroxyisobutyrate as complexing agents and that of methanol as the organic modifier were studied in detail and the results were compared with the theoretical model of ion-exchange separation. Simple mixtures of metals can be rapidly separated on a short column (30 x 3.3 mm i.d.), e.g., with a mobile phase containing 10(-2) M tartrate at pH 6.0. The metals separated can be detected by dc amperometry at a hanging mercury drop electrode. The limits of detection at an electrode potential of -0.95 V (Ag/AgCl) are in the units-tens of ng range with 20-mu-l samples with satisfactory precision (RSD values of 2-6%). The main advantages of the method are rapidly and simplicity because derivatization of the analytes is not required.
引用
收藏
页码:1445 / 1452
页数:8
相关论文
共 41 条
[11]   APPLICATION OF INDIRECT POTENTIOMETRIC DETECTION WITH A METALLIC COPPER ELECTRODE TO ION CHROMATOGRAPHY OF TRANSITION-METAL IONS [J].
HADDAD, PR ;
ALEXANDER, PW ;
TROJANOWICZ, M .
JOURNAL OF CHROMATOGRAPHY, 1985, 324 (02) :319-332
[12]   MODELING OF CATION RETENTION IN ION CHROMATOGRAPHY USING FIXED-SITE AND DYNAMICALLY COATED ION-EXCHANGE COLUMNS [J].
HADDAD, PR ;
FOLEY, RC .
JOURNAL OF CHROMATOGRAPHY, 1990, 500 :301-312
[13]   ACIDITY OF SURFACE HYDROXYL GROUPS [J].
HAIR, ML ;
HERTL, W .
JOURNAL OF PHYSICAL CHEMISTRY, 1970, 74 (01) :91-&
[14]   COMPLEX-FORMING EQUILIBRIA IN ISOTACHOPHORESIS .5. ESTIMATION OF COORDINATION NUMBERS AND STABILITY-CONSTANTS OF METAL OXYCARBOXYLIC ACID COMPLEXES BY MEANS OF COMPUTER-SIMULATION [J].
HIROKAWA, T ;
MATSUKI, T ;
TAKEMI, H ;
KISO, Y .
JOURNAL OF CHROMATOGRAPHY, 1983, 280 (02) :233-247
[15]   POLAROGRAPHIC DETECTION BY REVERSE-PULSE AMPEROMETRY IN CATION-EXCHANGE CHROMATOGRAPHY WITHOUT INTERFERENCE FROM DISSOLVED-OXYGEN [J].
HSI, T ;
JOHNSON, DC .
ANALYTICA CHIMICA ACTA, 1985, 175 (SEP) :23-35
[16]   SIMULTANEOUS DETERMINATION OF SODIUM AND POTASSIUM-IONS IN RIVER WATER BY ION CHROMATOGRAPHY USING SILICA-GELS AS A STATIONARY PHASE [J].
IWACHIDO, T ;
ISHIMARU, K ;
MOTOMIZU, S .
ANALYTICAL SCIENCES, 1988, 4 (01) :81-85
[17]   DETERMINATION OF AMMONIUM AND OTHER MAJOR CATIONS IN RIVER AND RAIN WATER BY ION CHROMATOGRAPHY USING SILICA-GEL AS AN ION-EXCHANGER [J].
IWACHIDO, T ;
IKEDA, T ;
ZENKI, M .
ANALYTICAL SCIENCES, 1990, 6 (04) :593-597
[18]   ELECTROCHEMICAL DETECTORS FOR ION CHROMATOGRAPHIC ANALYSIS - A CRITICAL-REVIEW [J].
JANDIK, P ;
HADDAD, PR ;
STURROCK, PE .
CRC CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 1988, 20 (01) :1-74
[19]   4-(PYRIDYLAZO)RESORCINOL-BASED CONTINUOUS DETECTION SYSTEM FOR TRACE LEVELS OF METAL-IONS [J].
JEZOREK, JR ;
FREISER, H .
ANALYTICAL CHEMISTRY, 1979, 51 (03) :373-376
[20]   FLUORESCENCE DETECTION OF METAL-IONS SEPARATED ON A SILICA-BASED HPLC REVERSED-PHASE SUPPORT [J].
KARCHER, BD ;
KRULL, IS .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1987, 25 (10) :472-478