THE EFFECT OF SETUP UNCERTAINTIES ON THE TREATMENT OF NASOPHARYNX CANCER

被引:84
作者
HUNT, MA
KUTCHER, GJ
BURMAN, C
FASS, D
HARRISON, L
LEIBEL, S
FUKS, Z
机构
[1] MEM SLOAN KETTERING CANC CTR,DEPT MED PHYS,NEW YORK,NY 10021
[2] MEM SLOAN KETTERING CANC CTR,DEPT RADIAT ONCOL,NEW YORK,NY 10021
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1993年 / 27卷 / 02期
关键词
CONFORMAL TREATMENT PLANNING; TREATMENT REPRODUCIBILITY; NASOPHARYNX CANCER;
D O I
10.1016/0360-3016(93)90257-V
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: As radiation treatment techniques become more complicated, the need to understand the effect of uncertainties on dose distributions increases. This study investigates the effect of positional uncertainities for patients with nasopharynx carcinoma treated with a multiple field conformal boost technique. Three dimensional setup errors were measured for six patients and the effect on patient dose was evaluated using dose volume histograms. Methods and Materials: A method is presented for determining 3-dimensional translational and rotational setup errors by identifying anatomical landmarks on two treatment field images and their corresponding simulation images. Measurements were made on a daily basis for six patients undergoing conformal treatment. Results: The average magnitude of the translational errors was between 1.5 and 3 mm while the average distance between simulation and treatment isocenters was 5 mm. Both systematic and random setup errors were observed. Dose volume histograms incorporating these uncertainties for standard parallel opposed and conformal techniques were generated for patients experiencing random and systematic setup errors. Conclusion: The data imply that positional uncertainties effect the daily dose distributions for target and critical structures differently and that the effect may be treatment technique dependent. These results demonstrate the need to measure setup uncertainties for all sites and to develop techniques for incorporating dose uncertainties in treatment plans.
引用
收藏
页码:437 / 447
页数:11
相关论文
共 18 条
  • [1] FAST EVALUATION OF PATIENT SET-UP DURING RADIOTHERAPY BY ALIGNING FEATURES IN PORTAL AND SIMULATOR IMAGES
    BIJHOLD, J
    VANHERK, M
    VIJLBRIEF, R
    LEBESQUE, JV
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (12) : 1665 - 1679
  • [2] DAILY MONITORING AND CORRECTION OF RADIATION-FIELD PLACEMENT USING A VIDEO-BASED PORTAL IMAGING-SYSTEM - A PILOT-STUDY
    EZZ, A
    MUNRO, P
    PORTER, AT
    BATTISTA, J
    JAFFRAY, DA
    FENSTER, A
    OSBORNE, S
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1992, 22 (01): : 159 - 165
  • [3] LIMITATIONS OF TWO-DIMENSIONAL TREATMENT PLANNING PROGRAMS
    GOITEIN, M
    [J]. MEDICAL PHYSICS, 1982, 9 (04) : 580 - 586
  • [4] CALCULATION OF THE UNCERTAINTY IN THE DOSE DELIVERED DURING RADIATION-THERAPY
    GOITEIN, M
    [J]. MEDICAL PHYSICS, 1985, 12 (05) : 608 - 612
  • [5] KINZIE JJ, 1983, CANCER, V52, P2223, DOI 10.1002/1097-0142(19831215)52:12<2223::AID-CNCR2820521209>3.0.CO
  • [6] 2-D
  • [7] KUTCHER G J, 1991, International Journal of Radiation Oncology, Biology, Physics, V21, P123, DOI 10.1016/0360-3016(91)90449-E
  • [8] IMPROVED DOSE DISTRIBUTIONS FOR 3D CONFORMAL BOOST TREATMENTS IN CARCINOMA OF THE NASOPHARYNX
    LEIBEL, SA
    KUTCHER, GJ
    HARRISON, LB
    FASS, DE
    BURMAN, CM
    HUNT, MA
    MOHAN, R
    BREWSTER, LJ
    LING, CC
    FUKS, ZY
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 20 (04): : 823 - 833
  • [9] EFFECT OF IMMOBILIZATION ON LOCALIZATION ERROR IN RADIOTHERAPY OF HEAD AND NECK CANCER
    MARKS, JE
    HAUS, AG
    [J]. CLINICAL RADIOLOGY, 1976, 27 (02) : 175 - 177
  • [10] MARKS JE, 1976, CANCER, V37, P2755, DOI 10.1002/1097-0142(197606)37:6<2755::AID-CNCR2820370628>3.0.CO