QUANTITATIVE-ANALYSIS OF MINOCYCLINE BY LIQUID-CHROMATOGRAPHY ON POLY(STYRENE-DIVINYLBENZENE)

被引:9
作者
NAIDONG, W
THURANIRA, J
VERMEULEN, K
ROETS, E
HOOGMARTENS, J
机构
[1] Katholieke Universiteit Leuven Laboratorium voor Farmaceutische Chemie, Instituut voor Farmaceutische Wetenschappen, B-3000, Leuven
来源
JOURNAL OF LIQUID CHROMATOGRAPHY | 1992年 / 15卷 / 14期
关键词
D O I
10.1080/10826079208017200
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An isocratic liquid chromatographic method has been developed for assay and purity control of minocycline. All the potential impurities are well separated from the main component and from each other. The stationary phase is poly(styrene-divinylbenzene) (PSDVB), PLRP-S, 250 mm x 4.6 mm, which is heated at 60-degrees-C. The mobile phase is 2-methyl-2-propanol (x g/100 ml) - 0.2 M potassium phosphate buffer pH 10.5 (10.0 ml) - 0.02 M tetrabutylammonium sulphate pH 10.5 (10.0 ml) - 0.01 M sodium edetate pH 10.5 (10.0 ml) - water (up to 100 ml). The flow rate is 1.0 ml/min and UV detection is performed at 254 nm. The total analysis time does not exceed 30 min. official standards were compared and a number of commercial bulk samples and specialties were analysed. 4-Epiminocycline, 6-deoxy-6-demethyltetracycline and 7-monodemethyl-minocycline are the main impurities. 7-Didemethylminocycline, 9-minocycline and some impurities of unknown identity also can be present.
引用
收藏
页码:2529 / 2549
页数:21
相关论文
共 19 条
  • [1] [Anonymous], 1992, PHARMACOPEE FRANCAIS
  • [2] CHROMATOGRAPHIC CHARACTERISTICS OF POLYMER-BASED HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY PACKINGS
    DAWKINS, JV
    LLOYD, LL
    WARNER, FP
    [J]. JOURNAL OF CHROMATOGRAPHY, 1986, 352 : 157 - 167
  • [3] QUANTITATIVE-ANALYSIS OF DOXYCYCLINE AND RELATED SUBSTANCES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    DIHUIDI, K
    KUCHARSKI, MJ
    ROETS, E
    HOOGMARTENS, J
    VANDERHAEGHE, H
    [J]. JOURNAL OF CHROMATOGRAPHY, 1985, 325 (02): : 413 - 424
  • [4] A COLLABORATIVE STUDY OF THE ANALYSIS OF DOXYCYCLINE HYCLATE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY ON POLYSTYRENE-DIVINYLBENZENE PACKING MATERIALS
    HOOGMARTENS, J
    KHAN, NH
    VANDERHAEGHE, H
    VANDERLEEDEN, AL
    OOSTERBAAN, M
    VELDTULP, GL
    PLUGGE, W
    VANDERVLIES, C
    MIALANNE, D
    MELAMED, R
    MILLER, JHM
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1989, 7 (05) : 601 - 610
  • [5] HOOGMARTENS J, 1990, PHARMEUROPA, V2, P77
  • [6] HOOGMARTENS J, 1988, PHARMEUROPA, V1, P39
  • [7] QUANTITATIVE-ANALYSIS OF OXYTETRACYCLINE AND RELATED SUBSTANCES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    KHAN, NH
    ROETS, E
    HOOGMARTENS, J
    VANDERHAEGHE, H
    [J]. JOURNAL OF CHROMATOGRAPHY, 1987, 405 : 229 - 245
  • [8] QUANTITATIVE-ANALYSIS OF TETRACYCLINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY ON POLYSTYRENE-DIVINYLBENZENE PACKING MATERIALS
    KHAN, NH
    WERA, P
    ROETS, E
    HOOGMARTENS, J
    [J]. JOURNAL OF LIQUID CHROMATOGRAPHY, 1990, 13 (07): : 1351 - 1374
  • [9] MITSCHER LA, 1978, CHEM TETRACYCLINE AN
  • [10] NAIDONG W, 1989, Journal of Pharmaceutical and Biomedical Analysis, V7, P1691, DOI 10.1016/0731-7085(89)80183-9