OPTIMIZATION OF SELECTIVITY IN CAPILLARY ELECTROPHORESIS WITH EMPHASIS ON MICELLAR ELECTROKINETIC CAPILLARY CHROMATOGRAPHY

被引:44
作者
CORSTJENS, H
BILLIET, HAH
FRANK, J
LUYBEN, KCAM
机构
[1] Department of Biochemical Engineering, Delft University of Technology, 2628 BC Delft
关键词
D O I
10.1016/0021-9673(95)00594-D
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Separations in capillary electrophoresis and especially in micellar electrokinetic capillary chromatography are characterised by a large number of parameters and therefore difficult to optimise. This paper reviews recent approaches suitable for optimisation of selectivity in capillary electrophoresis. Typical features of optimisation strategies applicable to capillary electrophoresis and micellar electrokinetic capillary chromatography in particular are discussed. A distinction is made between statistical approaches, using fitting procedures of polynomial equations, and practical optimisation schemes, based on physicochemical models describing the migration behaviour. Besides speeding up the search in finding satisfactory separation conditions, additional knowledge may be obtained about the migration and separation mechanism(s) when a systematic approach is applied. However, due to the complexity and the number of available optimisation schemes, these approaches should not be used as black-box systems. The analyst has a crucial role in optimising a separation.
引用
收藏
页码:1 / 11
页数:11
相关论文
共 56 条
[1]   INFINITE ELUTION RANGE IN MICELLAR ELECTROKINETIC CAPILLARY CHROMATOGRAPHY USING A NONIONIC/ANIONIC MIXED MICELLAR SYSTEM [J].
AHUJA, ES ;
LITTLE, EL ;
NIELSEN, KR ;
FOLEY, JP .
ANALYTICAL CHEMISTRY, 1995, 67 (01) :26-33
[2]   TEMPERATURE-PROGRAMMED CAPILLARY AFFINITY GEL-ELECTROPHORESIS FOR THE SENSITIVE BASE-SPECIFIC SEPARATION OF OLIGODEOXYNUCLEOTIDES [J].
BABA, Y ;
TSUHAKO, M ;
SAWA, T ;
AKASHI, M .
JOURNAL OF CHROMATOGRAPHY, 1993, 632 (1-2) :137-142
[3]   EXTENSION OF ELUTION RANGE IN MICELLAR ELECTROKINETIC CAPILLARY CHROMATOGRAPHY [J].
BALCHUNAS, AT ;
SEPANIAK, MJ .
ANALYTICAL CHEMISTRY, 1987, 59 (10) :1466-1470
[4]   EFFECT OF SAMPLE STACKING ON RESOLUTION, CALIBRATION GRAPHS AND PH IN CAPILLARY ZONE ELECTROPHORESIS [J].
BECKERS, JL ;
ACKERMANS, MT .
JOURNAL OF CHROMATOGRAPHY, 1993, 629 (02) :371-378
[5]   RESOLUTION OF DIASTEREOMERIC PHOSPHORAMIDATE BRIDGED UNNATURAL OLIGONUCLEOTIDES BY MICELLAR ELECTROKINETIC CHROMATOGRAPHY [J].
BEVAN, CD ;
MUTTON, IM ;
PIPE, AJ .
JOURNAL OF CHROMATOGRAPHY, 1993, 636 (01) :113-123
[6]   OPTIMIZATION IN SAMPLE STACKING FOR HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS [J].
BURGI, DS ;
CHIEN, RL .
ANALYTICAL CHEMISTRY, 1991, 63 (18) :2042-2047
[7]  
CAMILLERI P, 1993, CAPILLARY ELECTROPHO
[8]   OPTIMIZATION OF PHENYLTHIOHYDANTOINAMINO ACID SEPARATION BY MICELLAR ELECTROKINETIC CAPILLARY CHROMATOGRAPHY [J].
CASTAGNOLA, M ;
ROSSETTI, DV ;
CASSIANO, L ;
RABINO, R ;
NOCCA, G ;
GIARDINA, B .
JOURNAL OF CHROMATOGRAPHY, 1993, 638 (02) :327-334
[9]   PEPTIDE-MAPPING OF COMPLEX PROTEINS AT THE LOW-PICOMOLE LEVEL WITH CAPILLARY ELECTROPHORETIC SEPARATIONS [J].
COBB, KA ;
NOVOTNY, MV .
ANALYTICAL CHEMISTRY, 1992, 64 (08) :879-886
[10]   CAPILLARY ZONE ELECTROPHORESIS OF OLIGONUCLEOTIDES - FACTORS AFFECTING SEPARATION [J].
DOLNIK, V ;
LIU, JP ;
BANKS, JF ;
NOVOTNY, MV ;
BOCEK, P .